The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Biodegradable Interference Screw Fixation Exhibits Pull-Out Force and Stiffness Similar to Titanium Screws
Abstract
Recently, increased interest in biodegradable interference screws for bone-tendon-bone graft fixation has led to numerous screws becoming available. The implants are made from different polymers and have different designs, which might influence their mechanical properties. Several studies have reported a wide range of mechanical results for these screws using different biomechanical models. The aim of the present study is to compare reliable biomechanical data for six different biodegradable interference screws, consisting of five different polymers, with a conventional titanium screw in a standardized model. Seventy proximal calf tibias were used to determine maximal pull-out force, stiffness of fixation, and insertion torque for interference screw fixation of bone-tendon-bone grafts. Additionally, maximal torque at failure was determined. Data were analyzed with respect to aspects of screw design, such as drive and thread shape. Five of the six biodegradable screws provided initial pull-out force and stiffness of fixation comparable with that of a conventional titanium screw. Torque at failure can be greatly increased by adapting the drive design to the mechanical properties of the polymeric raw material. A correlation between pull-out force and thread height indicates that fixation rigidity depends on screw design, even in a biodegradable implant.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
BÖSTMAN, O. M. (1992) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199205000-00031 · Cited by 185
Preliminary results of an absorbable interference screw
Barber, F. A., Elrod, B. F., McGuire, D. A., & Paulos, L. E. (1995) · Arthroscopy · doi:10.1016/0749-8063(95)90129-9 · Cited by 178
Cited by
Tendon healing in a bone tunnel. Part II
Weiler, A., Hoffmann, R. F. G., Bail, H. J., Rehm, O., & Südkamp, N. P. (2002) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1053/jars.2002.30657 · Cited by 481
Self-citationGraft Fixation in Cruciate Ligament Reconstruction
Brand, J., Weiler, A., Caborn, D. N. M., Brown, C. H., & Johnson, D. L. (2000) · The American Journal of Sports Medicine · doi:10.1177/03635465000280052501 · Cited by 436
Self-citationBiodegradable Materials for Bone Repairs: A Review
Tan, L., Yu, X., Wan, P., & Yang, K. (2013) · Journal of Materials Science & Technology · doi:10.1016/j.jmst.2013.03.002 · Cited by 431
Kousa, P., Järvinen, T. L. N., Vihavainen, M., Kannus, P., & Järvinen, M. (2003) · The American Journal of Sports Medicine · doi:10.1177/03635465030310020401 · Cited by 426
Arthroscopic biceps tenodesis: A new technique using bioabsorbable interference screw fixation
Boileau, P., Krishnan, S. G., Coste, J.-S., & Walch, G. (2002) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1053/jars.2002.36488 · Cited by 325
Metadata
- Authors
- Weiler, A., Windhagen, H. J., Raschke, M. J., Laumeyer, A., & Hoffmann, R. F. G.
- Venue
- The American Journal of Sports Medicine
- Publisher
- SAGE Publications
- Published
- 1998-01
- Volume
- 26
- Issue
- 1
- Pages
- 119-128
- ISSN
- 0363-5465 (ISSN-L)
- 1552-3365
- OpenAlex
- W1853099499
- Cited by
- 196
- References
- 2
- FWCI
- 7.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biodegradable Interference Screw Fixation Exhibits Pull-Out Force and Stiffness Similar to Titanium Screws. https://app.cochat.ai/papers/10.1177/03635465980260010401
- The paper
- Weiler, A., Windhagen, H. J., Raschke, M. J., Laumeyer, A., & Hoffmann, R. F. G. (1998). Biodegradable Interference Screw Fixation Exhibits Pull-Out Force and Stiffness Similar to Titanium Screws. The American Journal of Sports Medicine. https://doi.org/10.1177/03635465980260010401
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.