Biodegradable Interference Screw Fixation Exhibits Pull-Out Force and Stiffness Similar to Titanium Screws
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Recently, increased interest in biodegradable interference screws for bone-tendon-bone graft fixation has led to numerous screws becoming available. The implants are made from different polymers and have different designs, which might influence their mechanical properties. Several studies have reported a wide range of mechanical results for these screws using different biomechanical models. The aim of the present study is to compare reliable biomechanical data for six different biodegradable interference screws, consisting of five different polymers, with a conventional titanium screw in a standardized model. Seventy proximal calf tibias were used to determine maximal pull-out force, stiffness of fixation, and insertion torque for interference screw fixation of bone-tendon-bone grafts. Additionally, maximal torque at failure was determined. Data were analyzed with respect to aspects of screw design, such as drive and thread shape. Five of the six biodegradable screws provided initial pull-out force and stiffness of fixation comparable with that of a conventional titanium screw. Torque at failure can be greatly increased by adapting the drive design to the mechanical properties of the polymeric raw material. A correlation between pull-out force and thread height indicates that fixation rigidity depends on screw design, even in a biodegradable implant.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanical analysis of human ligament grafts used in knee-ligament repairs and reconstructions.
Noyes, F. R., Butler, D. L., Grood, E. S., Zernicke, R. F., & Hefzy, M. S. (1984) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198466030-00005 · Cited by 1,524 · cited 2×
“Although the actual force on the graft fixation site during normal activities has not been directly demonstrated, Noyes et al.(41) estimated that the ACL is loaded to approximately 450 N under normal activities.”
BackgroundAccelerated rehabilitation after anterior cruciate ligament reconstruction
Shelbourne, K. D., & Nitz, P. (1990) · The American Journal of Sports Medicine · doi:10.1177/036354659001800313 · Cited by 1,194 · cited 1×
“thus allowing early and aggressive rehabilitation resulting in an accelerated postoperative recovery.(34,37,52)”
BackgroundLate degradation tissue response to poly(?-lactide) bone plates and screws
Bergsma, J. (1995) · Biomaterials · doi:10.1016/0142-9612(95)91092-d · Cited by 799 · cited 1×
“However, even slow-degrading Poly-(L-lactide) implants may provoke late tissue reactions in the final stages of degradation because of the material’s crystallinity.(4,17,35,36,45) Synovial reactions to biodegradable implants after intraarticular use are sometimes associated with the release of implant fragments into t…”
BackgroundKurosaka, M., Yoshiya, S., & Andrish, J. T. (1987) · The American Journal of Sports Medicine · doi:10.1177/036354658701500306 · Cited by 745 · cited 2×
“The influence of thread diameter on pull-out force has been demonstrated for BPTB graft fixation.(6,7,9,27,32,34) Therefore, a potential limitation of the present study could be that screws with different thread diameters were used, making comparison of the different screws difficult.”
BackgroundDaniels, A. U., Chang, M. K. O., Andriano, K. P., & Heller, J. (1990) · Journal of Applied Biomaterials · doi:10.1002/jab.770010109 · Cited by 483 · cited 2×
“Many studies have investigated in vitro and in vivo degradation of different biodegradable materials, but the reported data are inconsistent because of the varying test conditions and the large variety of biodegradable materials used.(14) In principle, it is reasonable to assume that the crystalline polymeric material…”
BackgroundAnterior Cruciate Ligament Graft Fixation: Comparison of Hamstring and Patellar Tendon Grafts
Steiner, M. E., Hecker, A. T., Brown, C. H., & Hayes, W. C. (1994) · The American Journal of Sports Medicine · doi:10.1177/036354659402200215 · Cited by 398
Resorbable materials of poly(l-lactide)
Leenslag, J. W., Pennings, A. J., Bos, R. R. M., Rozema, F. R., & Boering, G. (1987) · Biomaterials · doi:10.1016/0142-9612(87)90121-9 · Cited by 329
BIODEGRADABLE IMPLANTS IN FRACTURE FIXATION: EARLY RESULTS OF TREATMENT OF FRACTURES OF THE ANKLE
Rokkanen, P., Vainionpää, S., Törmälä, P., Kilpikari, J., Böstman, O., Vihtonen, K., Laiho, J., & Tamminmäki, M. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91847-1 · Cited by 293 · cited 1×
“1980s, were rods and screws for the fixation of osteochondral fragments or apical fractures.(13,23,44) In these appli-”
BackgroundLAMBERT, K. L. (1983) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198301000-00016 · Cited by 228 · cited 1×
“thus allowing early and aggressive rehabilitation resulting in an accelerated postoperative recovery.(34,37,52)”
BackgroundBÖSTMAN, O. M. (1992) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199205000-00031 · Cited by 185
Preliminary results of an absorbable interference screw
Barber, F. A., Elrod, B. F., McGuire, D. A., & Paulos, L. E. (1995) · Arthroscopy · doi:10.1016/0749-8063(95)90129-9 · Cited by 178 · cited 1×
“The most frequently reported complication associated with use of biodegradable interference screws is screw breakage during insertion.(2,29,42) The screw resistance to breakage may depend on several factors, including core diameter, drive diameter, and drive shape (the drive is defined as the connection between the sc…”
BackgroundWeiler, A., Helling, H.-J., Kirch, U., et al. (1996) · PubMed · Cited by 156
Self-citationPena, F. A., Grøntvedt, T., Brown, G. A., Aune, A. K., & Engebretsen, L. (1996) · The American Journal of Sports Medicine · doi:10.1177/036354659602400314 · Cited by 155 · cited 7×
“It has been shown that circular bone blocks provide 20% greater pull-out force than trapezoidal bone blocks.50 Furthermore, Pena et al. prepared differentsized interference gaps, ranging from 3.7 to 5.5 mm, and used 7-mm interference screws.”
BackgroundInfluentialStähelin, A. C., Weiler, A., Rüfenacht, H., Hoffmann, R. F. G., Geissmann, A., & Feinstein, R. S. (1997) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/s0749-8063(97)90162-6 · Cited by 148 · cited 1×
“A potential problem associated with interference screw degradation is compromised biocompatibility, even though few complications occur in their clinical use.(55) This issue is still controversial because of reports of severe foreign body reaction with the use of fast-degrading, highly crystalline PGA implants.”
BackgroundSelf-citationThe biomechanics of interference screw fixation of patellar tendon anterior cruciate ligament grafts
Brown, C. H., Hecker, A. T., Hipp, J. A., Myers, E. R., & Hayes, W. C. (1993) · The American Journal of Sports Medicine · doi:10.1177/036354659302100622 · Cited by 147 · cited 1×
“The influence of thread diameter on pull-out force has been demonstrated for BPTB graft fixation.(6,7,9,27,32,34) Therefore, a potential limitation of the present study could be that screws with different thread diameters were used, making comparison of the different screws difficult.”
BackgroundSevere aseptic synovitis of the knee after biodegradable internal fixation
Fridén, T., & Rydholm, U. (1992) · Acta Orthopaedica Scandinavica · doi:10.3109/17453679209154859 · Cited by 132 · cited 1×
“This rare but severe complication has been reported after the use of PGA, Poly(glyclolide-cotrimethylene-carbonate), or Poly-(L-lactide) implants in the knee and shoulder joints.(3,16,18,20,58,59) Unfortunately, the intraarticular biocompatibility of biodegradable devices has not yet been studied in depth.”
BackgroundAdverse reactions to an absorbable shoulder fixation device
Edwards, D. J., Hoy, G., Saies, A. D., & Hayes, M. G. (1994) · Journal of Shoulder and Elbow Surgery · doi:10.1016/s1058-2746(09)80040-2 · Cited by 124 · cited 1×
“This rare but severe complication has been reported after the use of PGA, Poly(glyclolide-cotrimethylene-carbonate), or Poly-(L-lactide) implants in the knee and shoulder joints.(3,16,18,20,58,59) Unfortunately, the intraarticular biocompatibility of biodegradable devices has not yet been studied in depth.”
BackgroundRupp, S., Krauss, P. W., & Fritsch, E. W. (1997) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/s0749-8063(97)90210-3 · Cited by 120 · cited 1×
“Reference Rupp et al.(46) Johnson and van Dyk(29) Pena et al.”
BackgroundThe effect of phagocytosis of poly(L‐lactic acid) fragments on cellular morphology and viability
Lam, K. H., Schakenraad, J. M., Esselbrugge, H., Feijen, J., & Nieuwenhuis, P. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820271214 · Cited by 109 · cited 1×
“However, even slow-degrading Poly-(L-lactide) implants may provoke late tissue reactions in the final stages of degradation because of the material’s crystallinity.(4,17,35,36,45) Synovial reactions to biodegradable implants after intraarticular use are sometimes associated with the release of implant fragments into t…”
BackgroundBiodegradable rods versus Kirschner wire fixation of wrist fractures. A randomised trial
Casteleyn, P., Handelberg, F., & Haentjens, P. (1992) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.74b6.1332974 · Cited by 108 · cited 1×
“This issue is still controversial because of reports of severe foreign body reaction with the use of fast-degrading, highly crystalline PGA implants.(5,11,24,59) However, even slow-degrading Poly-(L-lactide) implants may provoke late tissue reactions in the final stages of degradation because of the material’s crystal…”
BackgroundHulstyn, M. J., Fadale, P. D., Abate, J., & Walsh, W. R. (1993) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/s0749-8063(05)80316-0 · Cited by 91
Local foreign-body reactions to biodegradable implants
Hoffmann, R. F. G., Weiler, A., Helling, H. J., Krettek, C., & Rehm, K. E. (1997) · Der Unfallchirurg · doi:10.1007/s001130050172 · Cited by 71
Self-citation[Resorbable implants for refixation of osteochondral fragments in joint surfaces].
Claes, L., Burri, C., Kiefer, H., & Mutschler, W. (1986) · PubMed · Cited by 49
[Refixation of osteochondral fragments using absorbable plastic pins].
Greve, H., & Holste, J. (1985) · PubMed · Cited by 21
Cited by
Tendon healing in a bone tunnel. Part II
Weiler, A., Hoffmann, R. F. G., Bail, H. J., Rehm, O., & Südkamp, N. P. (2002) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1053/jars.2002.30657 · Cited by 481
Self-citationGraft Fixation in Cruciate Ligament Reconstruction
Brand, J., Weiler, A., Caborn, D. N. M., Brown, C. H., & Johnson, D. L. (2000) · The American Journal of Sports Medicine · doi:10.1177/03635465000280052501 · Cited by 436
Self-citationBiodegradable Materials for Bone Repairs: A Review
Tan, L., Yu, X., Wan, P., & Yang, K. (2013) · Journal of Materials Science & Technology · doi:10.1016/j.jmst.2013.03.002 · Cited by 431
Kousa, P., Järvinen, T. L. N., Vihavainen, M., Kannus, P., & Järvinen, M. (2003) · The American Journal of Sports Medicine · doi:10.1177/03635465030310020401 · Cited by 426
Arthroscopic biceps tenodesis: A new technique using bioabsorbable interference screw fixation
Boileau, P., Krishnan, S. G., Coste, J.-S., & Walch, G. (2002) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1053/jars.2002.36488 · Cited by 325
Metadata
- Authors
- Weiler, A., Windhagen, H. J., Raschke, M. J., Laumeyer, A., & Hoffmann, R. F. G.
- Venue
- The American Journal of Sports Medicine
- Publisher
- SAGE Publications
- Published
- 1998-01
- Volume
- 26
- Issue
- 1
- Pages
- 119-128
- ISSN
- 0363-5465 (ISSN-L)
- 1552-3365
- OpenAlex
- W1853099499
- Cited by
- 196
- References
- 24
- FWCI
- 7.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›