Protein Adsorption and Cellular Adhesion and Activation on Biomedical Polymers
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The design and development of new biomedical polymers for clinical application in devices, prostheses, and artificial organs requires a basic and fundamental understanding of biological interactions with biomedical polymers. Efforts in our laboratory have been directed towards appreciating the humoral and cellular interactions which govern protein adsorption and cellular adhesion and activation on biomedical polymers. Information and data are presented on protein adsorption from whole human blood, complement activation and receptors, and monocyte/macrophage adhesion and activation with growth factor release. Supported by experimental evidence, concepts regarding protein/polymer, cell/ polymer, cell/protein/polymer, and cell/cell interactions as they are related to in vivo events are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Inflammatory Response to Implants
Anderson, J. M. (1988) · ASAIO Journal · doi:10.1097/00002480-198804000-00005 · Cited by 591
Self-citationBiomaterial biocompatibility and the macrophage
Anderson, J. M., & Miller, K. M. (1984) · Biomaterials · doi:10.1016/0142-9612(84)90060-7 · Cited by 403 · cited 1×
“prostheses for periods extending up to 15 years (6, 7).”
BackgroundSelf-citationHuman monocyte/macrophage activation and interleukin 1 generation by biomedical polymers
Miller, K. M., & Anderson, J. M. (1988) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820220805 · Cited by 156 · cited 1×
“These correlations were also verified by scanning electron microscopic studies for gross morphological evaluation of the adherent cell population (17, 18).”
MethodSelf-citationBonfield, T. L., Colton, E., & Anderson, J. M. (1989) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820230602 · Cited by 76 · cited 1×
“Expanded PTFE resulted in intermediate levels of IL-1 and attached cells showing activated morphology (19).”
BackgroundSelf-citationMiller, K. M., Huskey, R. A., Bigby, L. F., & Anderson, J. M. (1989) · Biomaterials · doi:10.1016/0142-9612(89)90023-9 · Cited by 54
Self-citation
Cited by
Surface Chemistry Influences Implant Biocompatibility
Tang, L., Thevenot, P., & Hu, W. (2008) · Current Topics in Medicinal Chemistry · doi:10.2174/156802608783790901 · Cited by 800
Macrophages, Foreign Body Giant Cells and Their Response to Implantable Biomaterials
Sheikh, Z., Brooks, P., Barzilay, O., Fine, N., & Glogauer, M. (2015) · Materials · doi:10.3390/ma8095269 · Cited by 701
“As explained previously, immediately after implantation, the biomaterial surface is covered with a layer of plasma proteins [165,166], and these proteins, possibly via hydrophobic interactions, adopt an altered conformation and to expose the hydrophobic domains which are highly adherent to hydrophobic biomaterial surf…”
BackgroundFibrin(ogen) mediates acute inflammatory responses to biomaterials.
Tang, L., & Eaton, J. W. (1993) · The Journal of experimental medicine · doi:10.1084/jem.178.6.2147 · Cited by 449
Engineering biomaterials to integrate and heal: The biocompatibility paradigm shifts
Bryers, J. D., Giachelli, C. M., & Ratner, B. D. (2012) · Biotechnology and Bioengineering · doi:10.1002/bit.24559 · Cited by 271
“Albumin, Fg, and immunoglobulin (IgG) have been shown to predominate at the tissue–material interface of many implanted biomaterials, including poly(ethylene terephthalate) (PET), expanded poly(tetrafluoroethylene) (ePTFE), poly(urethanes) (PU), and poly(ethylene) (PE) (Andrade and Hlady, 1987; Anderson et al., 1990;…”
BackgroundPolypeptide growth factors: targeted delivery systems
Nimni, M. E. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00050-1 · Cited by 260
Metadata
- Authors
- Anderson, J. M., Bonfield, T. L., & Ziats, N. P.
- Venue
- The International Journal of Artificial Organs
- Publisher
- SAGE Publications
- Published
- 1990-06
- Volume
- 13
- Issue
- 6
- Pages
- 375-382
- ISSN
- 0391-3988 (ISSN-L)
- 1724-6040
- OpenAlex
- W160074307
- Cited by
- 134
- References
- 5
- FWCI
- 3.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.