Development of a Hybrid Liver Support System: A Review
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Hybrid liver support systems (LSS) for the use of the detoxifying, metabolic synthetic and regulatory capabilities of liver cells are under development for extracorporeal therapy of acute liver failure and for bridging to liver transplantation. A summary of our development is discussed. A five-step technique for primary liver cell isolation has been introduced in order to address larger scale procurement of hepatocytes. Immobilisation of the cells after isolation appears to be one of the main factors in maintaining hepatocyte function in vitro. Different techniques have been investigated. Using the cell-cell adhesion technique, a culture model was developed for the immobilisation of hepatocytes between capillary membranes. Four separate capillary membrane systems, each forming independent compartments are woven in order to create a three dimensional network. A bioreactor design has been developed. The construction provides different functions, including decentralised cell perfusion. The bioreactor enables 3 dimensional reorganisation of cells, integral oxygenation and decentralised metabolite exchange. The bioreactor has been scaled-up to allow hepatocytes and sinusoidal endothelial cells to be cultured in quantities sufficient for therapeutic application. In a healthy pig model, possible limiting side effects of therapy with this device were excluded. The efficacy of the system has been demonstrated in a hepatectomised pig model. Subsequently, a complete hybrid liver support system for human studies was introduced and applied clinically.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cell Culture on Artificial Capillaries: an Approach to Tissue Growth In Vitro
Knazek, R. A., Gullino, P. M., Kohler, P. O., & Dedrick, R. L. (1972) · Science · doi:10.1126/science.178.4056.65 · Cited by 424 · cited 1×
“The first capillary membrane liver cell bioreactor was described in 1972 (31).”
Background
Cited by
Bioreactor design for tissue engineering
Pörtner, R., Nagel-Heyer, S., Goepfert, C., Adamietz, P., & Meenen, N. M. (2005) · Journal of Bioscience and Bioengineering · doi:10.1263/jbb.100.235 · Cited by 305
Marx, U. (2016) · ALTEX · doi:10.14573/altex.1603161 · Cited by 295
“These dynamic perfusion tissue culture systems later were advanced into functional long-term in vitro organ equivalents introduced into medical practice as extracorporeal bioartificial liver devices in the late-1990s (Catapano and Gerlach, 2007; Gerlach, 1996; Wang et al., 2010).”
Clinical Application of Bioartificial Liver Support Systems
van de Kerkhove, M. P., Hoekstra, R., Chamuleau, R. A. F. M., & van Gulik, T. M. (2004) · Annals of Surgery · doi:10.1097/01.sla.0000132986.75257.19 · Cited by 210
Fukuda, J., Okamura, K., Nakazawa, K., Ijima, H., Yamashita, Y., Shimada, M., Shirabe, K., Tsujita, E., Sugimachi, K., & Funatsu, K. (2003) · Cell Transplantation · doi:10.3727/000000003783985151 · Cited by 54
Diekmann, S., Bader, A., & Schmitmeier, S. (2006) · Cytotechnology · doi:10.1007/s10616-006-6336-4 · Cited by 32
Metadata
- Authors
- Gerlach, J. C.
- Venue
- The International Journal of Artificial Organs
- Publisher
- SAGE Publications
- Published
- 1996-11
- Volume
- 19
- Issue
- 11
- Pages
- 645-654
- ISSN
- 0391-3988 (ISSN-L)
- 1724-6040
- OpenAlex
- W350594800
- Cited by
- 190
- References
- 1
- FWCI
- 10.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.