Entrainment Concepts Revisited
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The traditional approaches to predict entrainment of circadian clocks by light are based on 2 concepts that were never successfully unified: the non-parametric approach assumes that entrainment occurs via discrete daily phase shifts while the parametric approach assumes that entrainment involves changes of the clock’s velocity. Here the authors suggest a new approach to predict and model entrainment. Unlike the traditional approaches, it does not assume a priori the mechanism of how the internal and external cycle lengths are matched (via phase shifts, velocity changes, or even other mechanisms). It is based on a circadian integrated response characteristic (CIRC) that describes how the circadian system integrates light signals at different circadian phases, without specifying exactly when and how fast its progression is affected. Light around subjective dawn compresses the internal cycle; light around subjective dusk expands it. While the phase response curve (PRC) describes the results of experiments using light stimuli (of specified duration and intensity), the CIRC reflects how the system integrates any given light profile, be it single pulses or any form of light-dark cycle (from skeleton photoperiods to natural light profiles). CIRCs are characterized by their shape (determining the extent of their dead zone) and their asymmetry (the ratio of its compressing and expanding portions). They are dimensionless (time/time), and their maximum is by definition 1. To make predictions about entrainment, the CIRC is multiplied with the light intensity/sensitivity at any given time point. Unlike the PRC and the velocity response curve, the CIRC can be assessed on the basis of entrained steady states, by modeling experimental results. The CIRC approach makes several predictions that can be tested experimentally.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stability, precision, and near-24-hour period of the human circadian pacemaker
Czeisler, C. A., Duffy, J. F., Shanahan, T. L., Brown, E. N., Mitchell, J. F., Rimmer, D. W., Ronda, J. M., Silva, E. J., Allan, J. S., Emens, J. S., et al. (1999) · Science · doi:10.1126/science.284.5423.2177 · Cited by 1,705 · cited 1×
“…outdoors and by using artificial light sources); the extremes in the human chronotype distribution are therefore almost 12 h out of phase (Roenneberg and Merrow, 2007) despite a relatively narrow proposed distribution of internal cycle length in humans (Czeisler et al., 1999; Wright et al., 2001).”
BackgroundPittendrigh, C. S., & Daan, S. (1976) · Journal of Comparative Physiology ? A · doi:10.1007/bf01417860 · Cited by 1,636 · cited 5×
“In nocturnal rodents, which show weak (type-1) resetting on the behavioral level, the predictive power of the PRC approach breaks down when the 2 pulses are close to each other (Comas et al., 2007; Pittendrigh and Daan, 1976b, figs.”
BackgroundInfluentialSelf-citationEntrainment of the Human Circadian Clock
Roenneberg, T., & Merrow, M. (2007) · Cold Spring Harbor Symposia on Quantitative Biology · doi:10.1101/sqb.2007.72.043 · Cited by 272
Self-citationPlasticity of the Intrinsic Period of the Human Circadian Timing System
Scheer, F. A. J. L., Wright, K. P., Kronauer, R. E., & Czeisler, C. A. (2007) · PLoS ONE · doi:10.1371/journal.pone.0000721 · Cited by 146
Photoperiod differentially modulates photic and nonphotic phase response curves of hamsters
Evans, J. A., Elliott, J. A., & Gorman, M. R. (2004) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00456.2003 · Cited by 45
Cited by
Roenneberg, T., Allebrandt, K. V., Merrow, M., & Vetter, C. (2012) · Current Biology · doi:10.1016/j.cub.2012.03.038 · Cited by 1,407
Self-citationEntrainment of the Human Circadian Clock to the Natural Light-Dark Cycle
Wright, K. P., McHill, A. W., Birks, B. R., Griffin, B. R., Rusterholz, T., & Chinoy, E. D. (2013) · Current Biology · doi:10.1016/j.cub.2013.06.039 · Cited by 783
“We also examined light exposure in the first 2 hr after awakening, when the human circadian clock is most sensitive to the phase advancing effects of light [13, 14] or to the compression of internal cycle length [15].”
BackgroundSleep timing, chronotype and social jetlag: Impact on cognitive abilities and psychiatric disorders
Taillard, J., Sagaspe, P., Philip, P., & Bioulac, S. (2021) · Biochemical Pharmacology · doi:10.1016/j.bcp.2021.114438 · Cited by 288
Light and the Human Circadian Clock
Roenneberg, T., Kantermann, T., Juda, M., Vetter, C., & Allebrandt, K. V. (2013) · Handbook of Experimental Pharmacology · doi:10.1007/978-3-642-25950-0_13 · Cited by 220
“For example, the velocity at which circadian clocks move through their daily cycle is most probably not constant [55]; and temperature compensation of the free-running period does not mean that circadian clocks are insensitive to temperature changes, on the contrary, most of them can perfectly synchronise to temperatu…”
BackgroundMethodSelf-citationGottlieb, J. F., Benedetti, F., Geoffroy, P. A., Henriksen, T. E. G., Lam, R. W., Murray, G., Phelps, J., Sit, D., Swartz, H. A., Crowe, M., et al. (2019) · Bipolar Disorders · doi:10.1111/bdi.12847 · Cited by 196
Metadata
- Authors
- Roenneberg, T., Hut, R., Daan, S., & Merrow, M.
- Venue
- Journal of Biological Rhythms
- Publisher
- SAGE Publications
- Published
- 2010-09-28
- Volume
- 25
- Issue
- 5
- Pages
- 329-339
- ISSN
- 0748-7304 (ISSN-L)
- 1552-4531
- OpenAlex
- W2085237971
- Cited by
- 81
- References
- 5
- FWCI
- 2.40
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.