A Simpler Model of the Human Circadian Pacemaker
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Numerous studies have used the classic van der Pol oscillator, which contains a cubic nonlinearity, to model the effect of light on the human circadian pacemaker. Jewett and Kronauer demonstrated that Aschoff's rule could be incorporated into van der Pol type models and used a van der Pol type oscillator with higher order nonlinearities. Kronauer, Forger, and Jewett have proposed a model for light preprocessing, Process L, representing a biochemical process that converts a light signal into an effective drive on the circadian pacemaker. In the paper presented here, the authors use the classic van der Pol oscillator with Process L and Jewett and Kronauer's model of Aschoff's rule to model the human circadian pacemaker. This simpler cubic model predicts the results of a three-pulse human phase response curve experiment and a two-pulse amplitude reduction study with as much, or more, accuracy as the models of Jewett and Kronauer and Kronauer, Forger, and Jewett, which both employ a nonlinearity of degree 7. This suggests that this simpler cubic model should be considered as a potential alternative to other models of the human circadian system currently available.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stability, precision, and near-24-hour period of the human circadian pacemaker
Czeisler, C. A., Duffy, J. F., Shanahan, T. L., Brown, E. N., Mitchell, J. F., Rimmer, D. W., Ronda, J. M., Silva, E. J., Allan, J. S., Emens, J. S., et al. (1999) · Science · doi:10.1126/science.284.5423.2177 · Cited by 1,705 · cited 8×
“Jewett et al. (1994) have shown that the human circadian pacemaker acts as a limit cycle oscillator.”
BackgroundMethodResultInfluentialSelf-citation
Cited by
Walch, O., Huang, Y., Forger, D., & Goldstein, C. (2019) · Sleep · doi:10.1093/sleep/zsz180 · Cited by 240
“In an effort to incorporate longitudinal, personalized information about the subjects’ circadian clocks, such as their phase at the time of sleep onset, we also computed the clock proxy feature using well-validated mathematical model of the circadian clock [35].”
MethodSelf-citationSkeldon, A. C., Derks, G., & Dijk, D.-J. (2016) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2015.05.011 · Cited by 165
Skeldon, A. C., Phillips, A. J. K., & Dijk, D.-J. (2017) · Scientific Reports · doi:10.1038/srep45158 · Cited by 155
“This dependence of the intrinsic period on light intensity is controlled by the parameter k in equation (4).”
BackgroundMethodSt. Hilaire, M. A., Klerman, E. B., Khalsa, S. B. S., Wright, K. P., Czeisler, C. A., & Kronauer, R. E. (2007) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2007.04.001 · Cited by 109
“Model predictions of 1-cycle/3-cycle pulses of bright light on the pacemaker— Previous models (Forger et al., 1999; Jewett et al., 1999; Kronauer et al., 1999, 2000) have accurately predicted the results of 3-pulse PRC experiments, which report the response of the pacemaker to 3 consecutive cycles…”
ResultSelf-citationKatori, M., Shi, S., Ode, K. L., Tomita, Y., & Ueda, H. R. (2022) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2116729119 · Cited by 75
Metadata
- Authors
- Forger, D. B., Jewett, M. E., & Kronauer, R. E.
- Venue
- Journal of Biological Rhythms
- Publisher
- SAGE Publications
- Published
- 1999-12
- Volume
- 14
- Issue
- 6
- Pages
- 533-538
- ISSN
- 0748-7304 (ISSN-L)
- 1552-4531
- OpenAlex
- W2145348595
- Cited by
- 163
- References
- 1
- FWCI
- 0.94
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Simpler Model of the Human Circadian Pacemaker. https://app.cochat.ai/papers/10.1177/074873099129000867
- The paper
- Forger, D. B., Jewett, M. E., & Kronauer, R. E. (1999). A Simpler Model of the Human Circadian Pacemaker. Journal of Biological Rhythms. https://doi.org/10.1177/074873099129000867
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.