Automated Tandem Mass Spectrometry for Mass Newborn Screening for Disorders in Fatty Acid, Organic Acid, and Amino Acid Metabolism
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Development of acylcarnitine and amino acid profiling using tandem mass spectrometry, and its application for use with dried blood specimens collected on filter-paper cards, has introduced an innovative new technology for detecting inborn errors of fatty acid, organic acid, and amino acid metabolism. From November 1, 1992 through June 30, 1999 we screened more than 700,000 newborns in Pennsylvania, Ohio, North Carolina, and Louisiana. We have prospectively detected 163 inborn errors of metabolism. Eighty-six patients have amino acid metabolism errors. Among them are phenylketonuria, hyperphenylalaninemia, maple syrup urine disease, and several urea cycle disorders. Thirty-two have organic acid metabolism errors, including glutaric aciduria type 1; 3-methylcrotonyl coenzyme A (CoA) carboxylase deficiency, propionic acidemia, methylmalonic acidemia, and 3-hydroxy-3-methylglutaryl-CoA lyase deficiency; and 45 have fatty acid oxidation errors, including 36 with medium-chain acyl-CoA dehydrogenase deficiency. Details of the methodology are presented and the potential of this screening technology is discussed. (J Child Neurol 1999;14(Suppl 1):S4-S8).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A SIMPLE PHENYLALANINE METHOD FOR DETECTING PHENYLKETONURIA IN LARGE POPULATIONS OF NEWBORN INFANTS
Guthrie, R., & Susi, A. (1963) · Pediatrics · doi:10.1542/peds.32.3.338 · Cited by 2,219
Millington, D. S., Kodo, N., Norwood, D. L., & Roe, C. R. (1990) · Journal of Inherited Metabolic Disease · doi:10.1007/bf01799385 · Cited by 571
Chace, D. H., Millington, D. S., Terada, N., Kahler, S. G., Roe, C. R., & Hofman, L. F. (1993) · Clinical Chemistry · doi:10.1093/clinchem/39.1.66 · Cited by 374
Self-citationRashed, M. S., Ozand, P. T., Bucknall, M. P., & Little, D. (1995) · Pediatric Research · doi:10.1203/00006450-199509000-00009 · Cited by 342
Chace, D. H., Hillman, S. L., Van Hove, J. L. K., & Naylor, E. W. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.11.2106 · Cited by 280
Self-citationChace, D. H., Hillman, S. L., Millington, D. S., Kahler, S. G., Roe, C. R., & Naylor, E. W. (1995) · Clinical Chemistry · doi:10.1093/clinchem/41.1.62 · Cited by 219
Self-citationMillington, D. S., Norwood, D. L., Kodo, N., Roe, C. R., & Inouet, F. (1989) · Analytical Biochemistry · doi:10.1016/0003-2697(89)90441-7 · Cited by 196
Chace, D. H., Sherwin, J. E., Hillman, S. L., Lorey, F., & Cunningham, G. C. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.12.2405 · Cited by 182
Self-citationZiadeh, R., Hoffman, E. P., Finegold, D. N., Hoop, R. C., Brackett, J. C., Strauss, A. W., & Naylor, E. W. (1995) · Pediatric Research · doi:10.1203/00006450-199505000-00021 · Cited by 165
Self-citationChace, D. H., Hillman, S. L., Millington, D. S., Kahler, S. G., Adam, B. W., & Levy, H. L. (1996) · Clinical Chemistry · doi:10.1093/clinchem/42.3.349 · Cited by 136
Self-citationNewborn Screening by Tandem Mass Spectrometry: A New Era
Levy, H. L. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.12.2401 · Cited by 132
Newborn screening by tandem mass spectrometry (MS-MS)
Sweetman, L. (1996) · Clinical Chemistry · doi:10.1093/clinchem/42.3.345 · Cited by 76
(1996) · PEDIATRICS · doi:10.1542/peds.98.3.473 · Cited by 65
Desposito, F., Cho, S., Frías, J. L., Sherman, J., Wappner, R. S., & Wilson, M. G. (1996) · Cited by 62
Recent developments in neonatal screening.
Naylor, E. W. (1985) · PubMed · Cited by 6
Self-citation
Cited by
Measuring the metabolome: current analytical technologies
Dunn, W. B., Bailey, N. J. C., & Johnson, H. E. (2005) · The Analyst · doi:10.1039/b418288j · Cited by 924
Suggested guidelines for the diagnosis and management of urea cycle disorders
Häberle, J., Boddaert, N., Burlina, A., Chakrapani, A., Dixon, M., Huemer, M., Karall, D., Martinelli, D., Crespo, P., Santer, R., et al. (2012) · Orphanet Journal of Rare Diseases · doi:10.1186/1750-1172-7-32 · Cited by 628
Use of Tandem Mass Spectrometry for Multianalyte Screening of Dried Blood Specimens from Newborns
Chace, D. H., Kalas, T. A., & Naylor, E. W. (2003) · Clinical Chemistry · doi:10.1373/clinchem.2003.022178 · Cited by 621
Self-citationWant, E. J., O'Maille, G., Smith, C. A., Brandon, T. R., Uritboonthai, W., Qin, C., Trauger, S. A., & Siuzdak, G. (2006) · Analytical Chemistry · doi:10.1021/ac051312t · Cited by 564
Schulze, A., Lindner, M., Kohlmüller, D., Olgemöller, K., Mayatepek, E., & Hoffmann, G. F. (2003) · Pediatrics · doi:10.1542/peds.111.6.1399 · Cited by 519
Metadata
- Authors
- Naylor, E. W., & Chace, D. H.
- Venue
- Journal of Child Neurology
- Publisher
- SAGE Publications
- Published
- 1999-11
- Volume
- 14
- Issue
- 1_suppl
- Pages
- S4-S8
- ISSN
- 0883-0738 (ISSN-L)
- 1708-8283
- OpenAlex
- W1593848483
- Cited by
- 167
- References
- 15
- FWCI
- 6.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.