Factors and Interactions Affecting the Performance of Polyurethane Elastomers in Medical Devices
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Polyurethanes offer the greatest versatility in compositions and properties of any family of polymers. For implantable medical devices, a few specific elastomeric polyurethane compositions have demonstrated a combination of toughness, durability, biocompatibility and biostability not achieved by any other available material. Because of the complex behavior of implantable polyurethanes in the body environment, designers and fabricators of polyurethane-containing devices must pay particular attention to the choice of composition and design of components. Subsequent treatment during qualification, fabrication, sterilization, storage, implantation, in vivo operation and explantation also determine the performance and provide the means for assessing the efficacy of the polyurethane in the implanted device.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effect of Healing on Small Internal Diameter Arterial Graft Compliance
White, R., Goldberg, L., Hirose, F., Klein, S., Bosco, P., Miranda, R., Long, J., Nelson, R., & Shors, E. (1983) · Biomaterials, Medical Devices, and Artificial Organs · doi:10.3109/10731198309118791 · Cited by 38
Cited by
Pinchuk, L. (1995) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856294x00347 · Cited by 252
Elastomers for biomedical applications
Yoda, R. (1998) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856298x00046 · Cited by 226
Biocompatibility: Meeting a Key Functional Requirement of Next-Generation Medical Devices
Helmus, M. N., Gibbons, D. F., & Cebon, D. (2008) · Toxicologic Pathology · doi:10.1177/0192623307310949 · Cited by 170
“Cytotoxic leachables and degradation products, which may exhibit systemic effects if the dose is high, may result from the fabrication and sterilization methods used as well as ambient degradation by processes such as hydrolysis and oxidation over time (Coury et al., 1988; Stokes, 1987; Takahara et al., 1992).”
MethodRole for interleukin‐4 in foreign‐body giant cell formation on a poly(etherurethane urea) in vivo
Kao, W. J., McNally, A. K., Hiltner, A., & Anderson, J. M. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820291014 · Cited by 154
Synthesis of degradable, biocompatible, and tough block‐copolyesterurethanes
Hirt, T. D., Neuenschwander, P., & Suter, U. W. (1996) · Macromolecular Chemistry and Physics · doi:10.1002/macp.1996.021971221 · Cited by 78
Metadata
- Authors
- Coury, A. J., Slaikeu, P. C., Cahalan, P. T., Stokes, K. B., & Hobot, C. M.
- Venue
- Journal of Biomaterials Applications
- Publisher
- SAGE Publications
- Published
- 1988-04
- Volume
- 3
- Issue
- 2
- Pages
- 130-179
- ISSN
- 0885-3282 (ISSN-L)
- 1530-8022
- OpenAlex
- W2023912817
- Cited by
- 93
- References
- 1
- FWCI
- 1.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.