In vivo Testing of a Biostable Polyurethane
The DOI matches its Crossref record.
Abstract
At present all the commercially available "medical grade" urethane elastomers exhibit a phenomenon known as environmental stress cracking (ESC). This phenomenon is characterized by surface microcracking when the elastomer is elongated while in vivo. The degree of strain that is required to initiate microcracking varies from composition to composition. It has been found that harder compounds generally tend to have a higher strain threshold than corresponding softer ones. We theorized that this degradation occurs when certain enzymes (present only in vivo) attack and break down the ether linkages that link the polymer molecules together. Those elastomers that contain more ether linkages (such as the softer compositions) appear to microcrack more easily than elastomers with fewer ether linkages (such as the harder ones). The molecular composition of ChronoFlex™ urethane has been chosen so that the finished elastomer will be free of ether linkages; thus, it is expected to be immune from environmental stress cracking.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Degradation and stabilization of polyurethane elastomers
Xie, F., Zhang, T., Bryant, P., Kurusingal, V., Colwell, J. M., & Laycock, B. (2019) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.12.003 · Cited by 722
The Mechanical Behavior of Vascular Grafts: A Review
Salacinski, H. J., Goldner, S., Giudiceandrea, A., Hamilton, G., Seifalian, A. M., Edwards, A., & Carson, R. J. (2001) · Journal of Biomaterials Applications · doi:10.1106/na5t-j57a-jtdd-fd04 · Cited by 399
Compliance properties of conduits used in vascular reconstruction
Tai, N. R., Salacinski, H. J., Edwards, A., Hamilton, G., & Seifalian, A. M. (2000) · Journal of British Surgery · doi:10.1046/j.1365-2168.2000.01566.x · Cited by 267
Pinchuk, L. (1995) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856294x00347 · Cited by 252
Ward, W. K., Slobodzian, E. P., Tiekotter, K. L., & Wood, M. D. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00160-6 · Cited by 176
“The solid materials were (1) an amphiphilic polycarbonate-based polyurethane multipolymer (PU-SPEO) with silicone comprising 15–20% of the material and the PEO also comprising 15–20% [6,12,13] Polymer Technology Group, Berkeley, CA, 94710,) and (2) a segmented, aromatic, polycarbonate-based PU designed for medical imp…”
Method
Metadata
- Authors
- Szycher, M., Reed, A. M., & Siciliano, A. A.
- Venue
- Journal of Biomaterials Applications
- Publisher
- SAGE Publications
- Published
- 1991-10
- Volume
- 6
- Issue
- 2
- Pages
- 110-130
- ISSN
- 0885-3282 (ISSN-L)
- 1530-8022
- OpenAlex
- W2069424558
- Cited by
- 54
- References
- 0
- FWCI
- 1.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vivo Testing of a Biostable Polyurethane. https://app.cochat.ai/papers/10.1177/088532829100600202
- The paper
- Szycher, M., Reed, A. M., & Siciliano, A. A. (1991). In vivo Testing of a Biostable Polyurethane. Journal of Biomaterials Applications. https://doi.org/10.1177/088532829100600202
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.