Electromechanical Impedance Modeling for Adhesively Bonded Piezo-Transducers
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
The electromechanical impedance (EMI) technique for structural health monitoring (SHM) and nondestructive evaluation (NDE) employs piezoelectric-ceramic (PZT) patches, which are surface bonded to the monitored structures using adhesives. The adhesive forms a finitely thick, permanent interfacial layer between the host structure and the patch. Hence, the force transmission between the structure and the patch occurs through the bond layer, via shear mechanism, invariably causing shear lag. However, the impedance models developed so far ignore the associated shear lag and idealize the force transfer to occur at the ends of the patch. This paper analyses the mechanism of force transfer through the bond layer and presents a step-by-step derivation to integrate the shear lag effect into impedance formulations, both one-dimensional and two-dimensional. Further, using the integrated model, the influence of various parameters (associated with the bond layer) on the electromechanical admittance response is studied by means of a parametric study. It is found that the bond layer can significantly modify the measured electromechanical admittance if not carefully controlled during the installation of the PZT patch.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Use of piezoelectric actuators as elements of intelligent structures
Crawley, E. F., & de Luis, J. (1987) · AIAA Journal · doi:10.2514/3.9792 · Cited by 2,602
Harris, C. M., Crede, C. E., & Trent, H. M. (1962) · Physics Today · doi:10.1063/1.3058391 · Cited by 1,023
(1996) · Choice Reviews Online · doi:10.5860/choice.33-6329 · Cited by 991
Liang, C., Sun, F. P., & Rogers, C. A. (1994) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x9400500102 · Cited by 790 · cited 2×
“It should be noted that the inertial force term has been separately considered in impedance formulations (Liang et al., 1994), where, as a matter of fact, the shear lag effect has been ignored.”
BackgroundMethodFundamental Understanding of Piezoelectric Strain Sensors
Sirohi, J., & Chopra, I. (2000) · Journal of Intelligent Material Systems and Structures · doi:10.1106/8bfb-gc8p-xq47-ycq0 · Cited by 777 · cited 6×
“The treatment presented is generic in nature and not restricted to beam structures alone as in the case of Crawley and de Luis (1987) and Sirohi and Chopra (2000). Besides, dynamic equilibrium of the system has been considered rather than relying on equivalent length static coefficients.”
BackgroundMethodInfluentialImpedance-Based Health Monitoring of Civil Structural Components
Park, G., Cudney, H. H., & Inman, D. J. (2000) · Journal of Infrastructure Systems · doi:10.1061/(asce)1076-0342(2000)6:4(153 · Cited by 460 · cited 2×
“…cost-effective method for structural health monitoring (SHM) and nondestructive evaluation (NDE) of all types of engineering structures and systems (Sun et al., 1995; Ayres et al., 1998; Giurgiutiu and Zagrai, 2000, 2002; Park et al., 2000, 2001; Soh et al., 2000; Bhalla and Soh, 2003, 2004a,b).”
BackgroundMethodPerformance of smart piezoceramic patches in health monitoring of a RC bridge
Soh, C. K., Tseng, K. K.-H., Bhalla, S., & Gupta, A. (2000) · Smart Materials and Structures · doi:10.1088/0964-1726/9/4/317 · Cited by 407 · cited 1×
“…cost-effective method for structural health monitoring (SHM) and nondestructive evaluation (NDE) of all types of engineering structures and systems (Sun et al., 1995; Ayres et al., 1998; Giurgiutiu and Zagrai, 2000, 2002; Park et al., 2000, 2001; Soh et al., 2000; Bhalla and Soh, 2003, 2004a,b).”
MethodSelf-citationStructural Health Monitoring by Piezo-Impedance Transducers. I: Modeling
Bhalla, S., & Soh, C. K. (2004) · Journal of Aerospace Engineering · doi:10.1061/(asce)0893-1321(2004)17:4(154 · Cited by 351 · cited 8×
“Electro-mechanical admittance, which is the measured electrical parameter, can be decomposed and analyzed to extract the impedance parameters of the host structure (Bhalla and Soh, 2004b,c).”
BackgroundMethodSelf-citationFeasibility of using impedance‐based damage assessment for pipeline structures
Park, G., Cudney, H. H., & Inman, D. J. (2001) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.72 · Cited by 272 · cited 1×
“…cost-effective method for structural health monitoring (SHM) and nondestructive evaluation (NDE) of all types of engineering structures and systems (Sun et al., 1995; Ayres et al., 1998; Giurgiutiu and Zagrai, 2000, 2002; Park et al., 2000, 2001; Soh et al., 2000; Bhalla and Soh, 2003, 2004a,b).”
MethodQualitative impedance-based health monitoring of civil infrastructures
Ayres, J. W., Lalande, F., Chaudhry, Z., & Rogers, C. A. (1998) · Smart Materials and Structures · doi:10.1088/0964-1726/7/5/004 · Cited by 232 · cited 2×
“The numerical approach based on FEM, as outlined by Bhalla and Soh (2004b), was employed to determine the effective mechanical impedance of the host structure.”
Method
Cited by
Na, W. S., & Baek, J. (2018) · Sensors · doi:10.3390/s18051307 · Cited by 336
Gorgin, R., Luo, Y., & Wu, Z. (2020) · Ultrasonics · doi:10.1016/j.ultras.2020.106114 · Cited by 285
Park, G., Farrar, C. R., Scalea, F. L. D., & Coccia, S. (2006) · Smart Materials and Structures · doi:10.1088/0964-1726/15/6/020 · Cited by 264
Annamdas, V. G. M., & Soh, C. K. (2010) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x09352816 · Cited by 218
“The surface-bonded PZT transducer should have thin adhesive layer preferably one-third of the thickness of PZT transducer (Bhalla and Soh, 2004c).”
InfluentialSelf-citationSivasuriyan, A., Vijayan, D. S., LeemaRose, A., Revathy, J., Gayathri Monicka, S., Adithya, U. R., & Jebasingh Daniel, J. (2021) · Advances in Materials Science and Engineering · doi:10.1155/2021/2615029 · Cited by 29
“15mm(3), which were used to pledge to the exterior portion of the two aluminum blocks sizes 48 mm× 48 mm× 10mm(3) for monitoring [33].”
MethodRetracted
Metadata
- Authors
- Bhalla, S., & Soh, C. K.
- Venue
- Journal of Intelligent Material Systems and Structures
- Publisher
- SAGE Publications
- Published
- 2004-12
- Volume
- 15
- Issue
- 12
- Pages
- 955-972
- ISSN
- 1045-389X (ISSN-L)
- 1530-8138
- OpenAlex
- W2061749878
- Cited by
- 231
- References
- 13
- FWCI
- 7.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.