Digital Axillary and Non-Contact Infrared Thermometers for Children
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Axillary digital thermometers (ADTs) and non-contact (infrared) forehead thermometers (NCIFTs) are commonly used in pediatric settings, where an incorrect body temperature measurement may delay treatments or lead to incorrect diagnoses and therapies. Several studies comparing ADT or NCIFT with other methods have found conflicting results. To investigate whether ADT and NCIFT can be used interchangeably, a comparative observational study was conducted involving 205 children aged 0 to 14 years who were consecutively admitted to the pediatric emergency department. The Bland–Altman plot illustrated agreement between the two methods. A total of 217 pairs of measurements were compared; axillary measurements showed average values significantly higher than forehead measurements (37.52°C and 37.12°C; t = 7.42, p = .000), with a mean difference of 0.41°C between the two methods (range = −1.80 and +2.40). In this setting and population, ADT and NCIFT cannot be used interchangeably.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Although NCITs may be the primary tools for temperature screening during a pandemic, clinical studies have reported mixed performance in terms of their accuracies5–8.”
From Clinical evaluation of non-contact infrared thermometers (2021) · cites this paper as [6]
In the citing paper
“Franconi et al.6 performed a comparative observational study on a pediatric population and observed a significantly higher mean difference of − 0.41 °C.”
From Clinical evaluation of non-contact infrared thermometers (2021) · cites this paper as [6]
In the citing paper
“Overall, previous studies using clinical data from hospitals and transit centers have been inconclusive regarding the use and effectiveness of NCITs as a screening method during SARS and influenza outbreaks.”
From Clinical evaluation of non-contact infrared thermometers (2021) · cites this paper as [6]
Citations
Cites
Faul, F., Erdfelder, E., Lang, A.-G., & Buchner, A. (2007) · Behavior Research Methods · doi:10.3758/bf03193146 · Cited by 65,971
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1984) · PubMed · Cited by 2,436
Fever in under 5s: assessment and initial management
Nice Guideline Updates Team (2019) · Cited by 170
Thermometry in paediatric practice
El-Radhi, A. S. (2006) · Archives of Disease in Childhood · doi:10.1136/adc.2005.088831 · Cited by 160
Management of fever in children: Summary of the Italian pediatric society guidelines
Chiappini, E., Principi, N., Longhi, R. C., Tovo, P., Becherucci, P., Bonsignori, F., Esposito, S., Festini, F., Galli, L., Lucchesi, B., et al. (2009) · Clinical Therapeutics · doi:10.1016/j.clinthera.2009.08.006 · Cited by 116
Chiappini, E., Sollai, S., Longhi, R., Morandini, L., Laghi, A., Osio, C. E., Persiani, M., Lonati, S., Picchi, R., Bonsignori, F., et al. (2011) · Journal of Clinical Nursing · doi:10.1111/j.1365-2702.2010.03565.x · Cited by 77
Petersen-Smith, A., Barber, N., Coody, D. K., West, M. S., & Yetman, R. J. (1994) · The Journal of Pediatrics · doi:10.1016/s0022-3476(94)70129-6 · Cited by 56
Performance of a non-contact infrared thermometer in healthy newborns
Sollai, S., Dani, C., Berti, E., Fancelli, C., Galli, L., de Martino, M., & Chiappini, E. (2016) · BMJ Open · doi:10.1136/bmjopen-2015-008695 · Cited by 49
An evaluation of tympanic thermometry in a paediatric emergency department
El-Radhi, A. S. (2005) · Emergency Medicine Journal · doi:10.1136/emj.2004.022764 · Cited by 48
Research works printed but not linked: 4
- De Martino M., 2008, Minerva Pediatrica, 60, 489
- Lanham D. M., 1999, Pediatric Nursing, 25, 39
- McCallum L., 2012, Nursing Times, 108, 20
- Osio C. E., 2007, Minerva Pediatrica, 59, 327
Cited by
Zhao, Y., & Bergmann, J. (2023) · Sensors · doi:10.3390/s23177439 · Cited by 103
Khan, S., Saultry, B., Adams, S., Kouzani, A. Z., Decker, K., Digby, R., & Bucknall, T. (2021) · American Journal of Infection Control · doi:10.1016/j.ajic.2020.09.012 · Cited by 49
Clinical evaluation of non-contact infrared thermometers
Sullivan, S. J. L., Rinaldi, J. E., Hariharan, P., Casamento, J. P., Baek, S., Seay, N., Vesnovsky, O., & Topoleski, L. D. T. (2021) · Scientific Reports · doi:10.1038/s41598-021-99300-1 · Cited by 44
Dante, A., Franconi, I., Marucci, A. R., Alfes, C. M., & Lancia, L. (2020) · Journal of Pediatric Nursing · doi:10.1016/j.pedn.2019.11.014 · Cited by 13
Self-citationUse of non-contact infrared thermometers in rehabilitation patients: a randomized controlled study
Chen, Z., Wang, H., Wang, Y., Lin, H., Zhu, X.-P., & Wang, Y. (2021) · Journal of International Medical Research · doi:10.1177/0300060520984617 · Cited by 12
Metadata
- Authors
- Franconi, I., La Cerra, C., Marucci, A. R., Petrucci, C., & Lancia, L.
- Affiliations
- University of L'Aquila (IT)
- University of L’Aquila, Italy
- Corresponding author
- Lancia, Loreto
- Venue
- Clinical Nursing Research
- Publisher
- SAGE Publications
- Published
- 2016-11-08
- Volume
- 27
- Issue
- 2
- Pages
- 180-190
- ISSN
- 1054-7738 (ISSN-L)
- 1552-3799
- OpenAlex
- W2549499970
- Cited by
- 13
- References
- 23
- Citations by year
- 2024: 1 · 2023: 2 · 2022: 3 · 2021: 5 · 2020: 1 · 2019: 1
- FWCI
- 0.29
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Clinical Nursing Research (publishedVersion)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- IRIS Research product catalog (Sapienza University of Rome) (submittedVersion)
- Archivio Istituzionale della Ricerca - Università degli Studi dell Aquila (submittedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Thermal Regulation in Medicine
- Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
- Keywords
- non-contact infrared thermometer, body temperature measurement, pediatric patients, measurement agreement, pediatric emergency department, Bland-Altman analysis
- MeSH terms
- Adolescent, Axilla, Body Temperature, Child, Child, Preschool, Emergency Service, Hospital, Female, Fever, Forehead, Humans, Infant, Infant, Newborn, Male, Pediatrics, Sensitivity and Specificity, Thermometers, Reproducibility of Results
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Digital Axillary and Non-Contact Infrared Thermometers for Children. https://app.cochat.ai/papers/10.1177/1054773816676538
- The paper
- Franconi, I., La Cerra, C., Marucci, A. R., Petrucci, C., & Lancia, L. (2018). Digital Axillary and Non-Contact Infrared Thermometers for Children. Clinical Nursing Research. https://doi.org/10.1177/1054773816676538
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.