Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 171

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Noninvasive Assessment of Endothelium-Dependent Flow-Mediated Dilation of the Brachial Artery

Uehata, Akimi, Lieberman, Eric H, Gerhard, Marie D, Anderson, Todd J, Ganz, Peter, Polak, Joseph F, Creager, Mark A, Yeung, Alan C·1997·Vascular Medicine

Abstract

Coronary atherosclerosis is characterized by an early loss of endothelium-dependent vasodilation. However, the methods of assessing coronary endothelial function are invasive and difficult to repeat over time. Recently, a noninvasive ultrasound method has been widely used to measure flow-mediated dilation in the brachial artery as a surrogate test for endothelial function. We seek to further validate this method of measuring vascular function. The brachial artery diameters and blood flow of 20 normal volunteers (10 males and 10 females) were measured using high resolution (7.5 MHz) ultrasound and strain gauge plethysmography. Flow-mediated endothelium-dependent vasodilation was measured in the brachial artery during reactive hyperemia after 5 minutes of cuff occlusion in the upper arm. The brachial artery diameter increased maximally by 9.7 ± 4.3% from baseline at 1 min after cuff release and blood flow increased by 1002 ± 376%. Five min of cuff occlusion was sufficient to achieve 97 ± 6% of maximal brachial artery dilation and degree of dilation was not different whether the cuff was inflated proximally or distally to the image site. The intraobserver variability in measuring brachial diameters was 2.9 % and the variability of the hyperemic response was 1.4%. In young, healthy men and women, the baseline brachial artery diameter was the only factor that was predictive of the flow-mediated vasodilation response. The brachial noninvasive technique has been further validated by the determination of flow-mediated dilation. This method of assessing endothelial function may help to determine the importance of vasodilator dysfunction as a risk factor in the development of atherosclerosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/1358863x9700200203

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 171

Metadata

Authors
Uehata, A., Lieberman, E. H., Gerhard, M. D., Anderson, T. J., Ganz, P., Polak, J. F., Creager, M. A., & Yeung, A. C.
Venue
Vascular Medicine
Published
1997-05
Volume
2
Issue
2
Pages
87-92
ISSN
  • 1358-863X (ISSN-L)
  • 1477-0377
OpenAlex
W49602467
Cited by
171
References
2
FWCI
3.72
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Noninvasive Assessment of Endothelium-Dependent Flow-Mediated Dilation of the Brachial Artery. https://app.cochat.ai/papers/10.1177/1358863x9700200203
The paper
Uehata, A., Lieberman, E. H., Gerhard, M. D., Anderson, T. J., Ganz, P., Polak, J. F., Creager, M. A., & Yeung, A. C. (1997). Noninvasive Assessment of Endothelium-Dependent Flow-Mediated Dilation of the Brachial Artery. Vascular Medicine. https://doi.org/10.1177/1358863x9700200203

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.