Noninvasive Assessment of Endothelium-Dependent Flow-Mediated Dilation of the Brachial Artery
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Coronary atherosclerosis is characterized by an early loss of endothelium-dependent vasodilation. However, the methods of assessing coronary endothelial function are invasive and difficult to repeat over time. Recently, a noninvasive ultrasound method has been widely used to measure flow-mediated dilation in the brachial artery as a surrogate test for endothelial function. We seek to further validate this method of measuring vascular function. The brachial artery diameters and blood flow of 20 normal volunteers (10 males and 10 females) were measured using high resolution (7.5 MHz) ultrasound and strain gauge plethysmography. Flow-mediated endothelium-dependent vasodilation was measured in the brachial artery during reactive hyperemia after 5 minutes of cuff occlusion in the upper arm. The brachial artery diameter increased maximally by 9.7 ± 4.3% from baseline at 1 min after cuff release and blood flow increased by 1002 ± 376%. Five min of cuff occlusion was sufficient to achieve 97 ± 6% of maximal brachial artery dilation and degree of dilation was not different whether the cuff was inflated proximally or distally to the image site. The intraobserver variability in measuring brachial diameters was 2.9 % and the variability of the hyperemic response was 1.4%. In young, healthy men and women, the baseline brachial artery diameter was the only factor that was predictive of the flow-mediated vasodilation response. The brachial noninvasive technique has been further validated by the determination of flow-mediated dilation. This method of assessing endothelial function may help to determine the importance of vasodilator dysfunction as a risk factor in the development of atherosclerosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Non-invasive detection of endothelial dysfunction in children and adults at risk of atherosclerosis
Celermajer, D. S., Sorensen, K. E., Gooch, V. M., Spiegelhalter, D. J., Miller, O. I., Sullivan, I. D., Lloyd, J. K., & Deanfield, J. E. (1992) · The Lancet · doi:10.1016/0140-6736(92)93147-f · Cited by 4,742
Close Relation of Endothelial Function in the Human Coronary and Peripheral Circulations
Anderson, T. J., Uehata, A., Gerhard, M. D., Meredith, I. T., Knab, S., Delagrange, D., Lieberman, E. H., Ganz, P., Creager, M. A., Yeung, A. C., et al. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00327-4 · Cited by 2,033
Effects of endothelium-derived nitric oxide on peripheral arteriolar tone in man
Vallance, P., Collier, J., & Moncada, S. (1989) · The Lancet · doi:10.1016/s0140-6736(89)91013-1 · Cited by 1,590
Cited by
Corretti, M. C., Anderson, T. J., Benjamin, E. J., Celermajer, D., Charbonneau, F., Creager, M. A., Deanfield, J., Drexler, H., Gerhard-Herman, M., Herrington, D., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01746-6 · Cited by 4,604
Self-citationGreenland (2000) · doi:10.1161/01.cir.101.1.e16 · Cited by 924
Ultrasound Assessment of Flow-Mediated Dilation
Harris, R. A., Nishiyama, S. K., Wray, D. W., & Richardson, R. S. (2010) · Hypertension · doi:10.1161/hypertensionaha.110.150821 · Cited by 667
Urbina, E. M., Williams, R. V., Alpert, B. S., Collins, R. T., Daniels, S. R., Hayman, L., Jacobson, M., Mahoney, L., Mietus-Snyder, M., Rocchini, A., et al. (2009) · Hypertension · doi:10.1161/hypertensionaha.109.192639 · Cited by 641
Pyke, K. E., & Tschakovsky, M. E. (2005) · The Journal of Physiology · doi:10.1113/jphysiol.2005.089755 · Cited by 614
Improved analysis of brachial artery ultrasound using a novel edge-detection software system
Woodman, R. J., Playford, D. A., Watts, G. F., Cheetham, C., Reed, C., Taylor, R. R., Puddey, I. B., Beilin, L. J., Burke, V., Mori, T. A., et al. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.2.929 · Cited by 533
Behrendt, D., & Ganz, P. (2002) · The American Journal of Cardiology · doi:10.1016/s0002-9149(02)02963-6 · Cited by 499
Self-citationTakase, B., Uehata, A., Akima, T., Nagai, T., Nishioka, T., Hamabe, A., Satomura, K., Ohsuzu, F., & Kurita, A. (1998) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)00702-4 · Cited by 452
Self-citationGerhard, M., Walsh, B. W., Tawakol, A., Haley, E. A., Creager, S. J., Seely, E. W., Ganz, P., & Creager, M. A. (1998) · Circulation · doi:10.1161/01.cir.98.12.1158 · Cited by 296
Self-citationHambrecht, R., Hilbrich, L., Erbs, S., Gielen, S., Fiehn, E., Schoene, N., & Schuler, G. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00602-6 · Cited by 272
Raitakari, O. T., & Celermajer, D. S. (2000) · British Journal of Clinical Pharmacology · doi:10.1046/j.1365-2125.2000.00277.x · Cited by 272
Roman, M. J., Naqvi, T. Z., Gardin, J. M., Gerhard-Herman, M., Jaff, M., & Mohler, E. (2006) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2006.04.020 · Cited by 264
Herrington, D. M., Fan, L., Drum, M., Riley, W. A., Pusser, B. E., Crouse, J. R., Burke, G. L., McBurnie, M. A., Morgan, T. M., & Espeland, M. A. (2001) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1177/174182670100800512 · Cited by 187
Rho Kinase Inhibition Improves Endothelial Function in Human Subjects With Coronary Artery Disease
Nohria, A., Grunert, M. E., Rikitake, Y., Noma, K., Prsic, A., Ganz, P., Liao, J. K., & Creager, M. A. (2006) · Circulation Research · doi:10.1161/01.res.0000251668.39526.c7 · Cited by 170
Self-citationEtsuda, H., Takase, B., Kusano, H., Hamabe, A., Kuhara, R., Akima, T., Matsushima, Y., Arakawa, K., Satomura, K., Ohsuzu, F., et al. (1999) · Clinical Cardiology · doi:10.1002/clc.4960220610 · Cited by 124
Self-citationInsulin Resistance and Vascular Dysfunction in Nondiabetic Asian Indians
Raji, A., Gerhard-Herman, M. D., Warren, M., Silverman, S. G., Raptopoulos, V., Mantzoros, C. S., & Simonson, D. C. (2004) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2004-0087 · Cited by 98
“The digitalized images were then evaluated for analysis using edge detection software (25).”
MethodCircadian Variation of Endothelial Function in Idiopathic Dilated Cardiomyopathy
Maruo, T., Nakatani, S., Kanzaki, H., Kakuchi, H., Yamagishi, M., Kitakaze, M., Ohe, T., & Miyatake, K. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2005.09.118 · Cited by 35
Metadata
- Authors
- Uehata, A., Lieberman, E. H., Gerhard, M. D., Anderson, T. J., Ganz, P., Polak, J. F., Creager, M. A., & Yeung, A. C.
- Venue
- Vascular Medicine
- Publisher
- SAGE Publications
- Published
- 1997-05
- Volume
- 2
- Issue
- 2
- Pages
- 87-92
- ISSN
- 1358-863X (ISSN-L)
- 1477-0377
- OpenAlex
- W49602467
- Cited by
- 171
- References
- 3
- FWCI
- 3.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.