A Biodegradable Stent Based on Poly(L-Lactide) and Poly(4-Hydroxybutyrate) for Peripheral Vascular Application: Preliminary Experience in the Pig
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Purpose: To assess the technical feasibility and biocompatibility of a novel stent based on poly(L-lactide) (PLLA) and poly(4-hydroxybutyrate) (P4HB) for peripheral vascular applications. Methods: A polytetrafluoroethylene aortobi-iliac graft was implanted in 5 pigs through a midline abdominal incision. After transverse graft limb incision, 5 PLLA/P4HB stents and 5 metal stents (316L stainless steel) were randomly deployed at both iliac anastomotic sites with 6-mm balloon catheters. Angiography was performed to determine patency prior to sacrifice at 6 weeks. Stented segments were surgically explanted and processed for quantitative histomorphometry. Vascular injury and inflammation scores were assigned to the stented iliac segments. Results: No animals were lost during follow-up. All PLLA/P4HB stents were deployed within 2 minutes by balloon inflation to 8 bars without rupture of the stent struts or anastomotic suture. All stents were patent on postprocedural angiography. Histological analysis showed no signs of excessive recoiling or collapse. PLLA/P4HB stents demonstrated decreased residual lumen area and increased neointimal area after 6 weeks (12.27±0.62 and 8.40±1.03 mm 2, respectively) compared to 316L stents (13.54±0.84 and 6.90±1.11 mm 2, respectively) as the result of differences in stent areas (PLLA/P4HB: 4.31±0.15 mm 2; 316L: 2.73±0.29 mm 2). Vascular injury scores showed only mild vascular trauma for all stents (PLLA/P4HB: 0.41±0.59; 316L: 0.32±0.47). Inflammatory reaction was slightly higher around PLLA/P4HB stent struts (1.39±0.52) compared to 316L (1.09±0.50). Conclusion: Rapid balloon expansion of PLLA/P4HB stents is feasible without risk of strut rupture. PLLA/P4HB stents provide adequate mechanical stability after iliac anastomotic stenting in pigs. Smaller residual luminal areas in the PLLA/P4HB stents might have been caused by tissue ingrowth into the larger strut interspaces due to higher strut thickness (stent area) in this group. This limitation needs to be addressed in future work on the stent design.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Medical applications of poly-4-hydroxybutyrate: A strong flexible absorbable biomaterial
Martin, D. P., & Williams, S. F. (2003) · Biochemical Engineering Journal · doi:10.1016/s1369-703x(03)00040-8 · Cited by 510
Self-citationThe Road to Bioabsorbable Stents: Reaching Clinical Reality?
Erne, P., Schier, M., & Resink, T. J. (2006) · CardioVascular and Interventional Radiology · doi:10.1007/s00270-004-0341-9 · Cited by 249
Cited by
Biodegradable Metals for Cardiovascular Stents: from Clinical Concerns to Recent Zn‐Alloys
Bowen, P. K., Shearier, E. R., Zhao, S., Guillory, R. J., Zhao, F., Goldman, J., & Drelich, J. W. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201501019 · Cited by 544
Sustainability of biobased and biodegradable plastics
Sudesh, K., & Iwata, T. (2008) · CLEAN – Soil, Air, Water · doi:10.1002/clen.200700183 · Cited by 354
Novel high-strength, low-alloys Zn-Mg (< 0.1 wt% Mg) and their arterial biodegradation
Jin, H., Zhao, S., Guillory, R., Bowen, P. K., Yin, Z., Griebel, A., Schaffer, J., Earley, E. J., Goldman, J., & Drelich, J. W. (2018) · Materials Science and Engineering: C · doi:10.1016/j.msec.2017.11.021 · Cited by 271
Mini-Review: Biosynthesis of Poly(hydroxyalkanoates)
Lu, J., Tappel, R. C., & Nomura, C. T. (2009) · Polymer Reviews · doi:10.1080/15583720903048243 · Cited by 254
Long-term surveillance of zinc implant in murine artery: Surprisingly steady biocorrosion rate
Drelich, A. J., Zhao, S., Guillory, R. J., Drelich, J. W., & Goldman, J. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.05.045 · Cited by 188
Metadata
- Authors
- Bünger, C. M., Grabow, N., Sternberg, K., Goosmann, M., Schmitz, K.-P., Kreutzer, H. J., Ince, H., Kische, S., Nienaber, C. A., Martin, D. P., Williams, S. F., Klar, E., & Schareck, W.
- Venue
- Journal of Endovascular Therapy
- Publisher
- SAGE Publications
- Published
- 2007-10
- Volume
- 14
- Issue
- 5
- Pages
- 725-733
- ISSN
- 1526-6028 (ISSN-L)
- 1545-1550
- OpenAlex
- W2117332185
- Cited by
- 52
- References
- 2
- FWCI
- 1.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Biodegradable Stent Based on Poly(L-Lactide) and Poly(4-Hydroxybutyrate) for Peripheral Vascular Application: Preliminary Experience in the Pig. https://app.cochat.ai/papers/10.1177/152660280701400518
- The paper
- Bünger, C. M., Grabow, N., Sternberg, K., Goosmann, M., Schmitz, K.-P., Kreutzer, H. J., Ince, H., Kische, S., Nienaber, C. A., Martin, D. P., Williams, S. F., Klar, E., & Schareck, W. (2007). A Biodegradable Stent Based on Poly(L-Lactide) and Poly(4-Hydroxybutyrate) for Peripheral Vascular Application: Preliminary Experience in the Pig. Journal of Endovascular Therapy. https://doi.org/10.1177/152660280701400518
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.