A Biodegradable Stent Based on Poly(L-Lactide) and Poly(4-Hydroxybutyrate) for Peripheral Vascular Application: Preliminary Experience in the Pig

Bünger, Carsten Michael, Grabow, Niels, Sternberg, Katrin, Goosmann, Martin, Schmitz, Klaus-Peter, Kreutzer, Hans J., Ince, Hüseyin, Kische, Stefan, Nienaber, Christoph A., Martin, David P., Williams, Simon F., Klar, Ernst, Schareck, Wolfgang · 2007 · Journal of Endovascular Therapy
Cited by 52

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Purpose: To assess the technical feasibility and biocompatibility of a novel stent based on poly(L-lactide) (PLLA) and poly(4-hydroxybutyrate) (P4HB) for peripheral vascular applications. Methods: A polytetrafluoroethylene aortobi-iliac graft was implanted in 5 pigs through a midline abdominal incision. After transverse graft limb incision, 5 PLLA/P4HB stents and 5 metal stents (316L stainless steel) were randomly deployed at both iliac anastomotic sites with 6-mm balloon catheters. Angiography was performed to determine patency prior to sacrifice at 6 weeks. Stented segments were surgically explanted and processed for quantitative histomorphometry. Vascular injury and inflammation scores were assigned to the stented iliac segments. Results: No animals were lost during follow-up. All PLLA/P4HB stents were deployed within 2 minutes by balloon inflation to 8 bars without rupture of the stent struts or anastomotic suture. All stents were patent on postprocedural angiography. Histological analysis showed no signs of excessive recoiling or collapse. PLLA/P4HB stents demonstrated decreased residual lumen area and increased neointimal area after 6 weeks (12.27±0.62 and 8.40±1.03 mm 2, respectively) compared to 316L stents (13.54±0.84 and 6.90±1.11 mm 2, respectively) as the result of differences in stent areas (PLLA/P4HB: 4.31±0.15 mm 2; 316L: 2.73±0.29 mm 2). Vascular injury scores showed only mild vascular trauma for all stents (PLLA/P4HB: 0.41±0.59; 316L: 0.32±0.47). Inflammatory reaction was slightly higher around PLLA/P4HB stent struts (1.39±0.52) compared to 316L (1.09±0.50). Conclusion: Rapid balloon expansion of PLLA/P4HB stents is feasible without risk of strut rupture. PLLA/P4HB stents provide adequate mechanical stability after iliac anastomotic stenting in pigs. Smaller residual luminal areas in the PLLA/P4HB stents might have been caused by tissue ingrowth into the larger strut interspaces due to higher strut thickness (stent area) in this group. This limitation needs to be addressed in future work on the stent design.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/152660280701400518

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 52

Metadata

Authors
Bünger, C. M., Grabow, N., Sternberg, K., Goosmann, M., Schmitz, K.-P., Kreutzer, H. J., Ince, H., Kische, S., Nienaber, C. A., Martin, D. P., Williams, S. F., Klar, E., & Schareck, W.
Venue
Journal of Endovascular Therapy
Published
2007-10
Volume
14
Issue
5
Pages
725-733
ISSN
  • 1526-6028 (ISSN-L)
  • 1545-1550
OpenAlex
W2117332185
Cited by
52
References
2
FWCI
1.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Biodegradable Stent Based on Poly(L-Lactide) and Poly(4-Hydroxybutyrate) for Peripheral Vascular Application: Preliminary Experience in the Pig. https://app.cochat.ai/papers/10.1177/152660280701400518
The paper
Bünger, C. M., Grabow, N., Sternberg, K., Goosmann, M., Schmitz, K.-P., Kreutzer, H. J., Ince, H., Kische, S., Nienaber, C. A., Martin, D. P., Williams, S. F., Klar, E., & Schareck, W. (2007). A Biodegradable Stent Based on Poly(L-Lactide) and Poly(4-Hydroxybutyrate) for Peripheral Vascular Application: Preliminary Experience in the Pig. Journal of Endovascular Therapy. https://doi.org/10.1177/152660280701400518

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.