A Comparative Review of Thermography as a Breast Cancer Screening Technique
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Breast cancer is the most frequently diagnosed cancer of women in North America. Despite advances in treatment that have reduced mortality, breast cancer remains the second leading cause of cancer induced death. Several well established tools are used to screen for breast cancer including clinical breast exams, mammograms, and ultrasound. Thermography was first introduced as a screening tool in 1956 and was initially well accepted. However, after a 1977 study found thermography to lag behind other screening tools, the medical community lost interest in this diagnostic approach. This review discusses each screening tool with a focus brought to thermography. No single tool provides excellent predictability; however, a combination that incorporates thermography may boost both sensitivity and specificity. In light of technological advances and maturation of the thermographic industry, additional research is required to confirm the potential of this technology to provide an effective non-invasive, low risk adjunctive tool for the early detection of breast cancer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jemal, A., Siegel, R., Ward, E., Murray, T., Xu, J., & Thun, M. J. (2007) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.57.1.43 · Cited by 7,439
(1971) · Annals of Internal Medicine · doi:10.7326/0003-4819-75-6-991_4 · Cited by 2,379
Canadian Cancer Statistics 2012: (611042012-001)
(2012) · PsycEXTRA Dataset · doi:10.1037/e611042012-001 · Cited by 1,492
Boyd, N. F., Byng, J. W., Jong, R. A., Fishell, E. K., Little, L. E., Miller, A. B., Lockwood, G. A., Tritchler, D. L., & Yaffe, M. J. (1995) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/87.9.670 · Cited by 1,105
Ten-Year Risk of False Positive Screening Mammograms and Clinical Breast Examinations
Elmore, J. G., Barton, M. B., Moceri, V. M., Polk, S., Arena, P. J., & Fletcher, S. W. (1998) · New England Journal of Medicine · doi:10.1056/nejm199804163381601 · Cited by 1,053
(1964) · Medical Journal of Australia · doi:10.5694/j.1326-5377.1964.tb134286.x · Cited by 742
Harris, J. R., Lippman, M. E., Veronesi, U., & Willett, W. (1992) · New England Journal of Medicine · doi:10.1056/nejm199207303270505 · Cited by 701
Nitric oxide synthase activity in human breast cancer
Thomsen, L., Miles, D., Happerfield, L., Bobrow, L., Knowles, R., & Moncada, S. (1995) · British Journal of Cancer · doi:10.1038/bjc.1995.274 · Cited by 626
Effect of Age, Breast Density, and Family History on the Sensitivity of First Screening Mammography
Kerlikowske, K. (1996) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1996.03540010035027 · Cited by 624
A reappraisal of the use of infrared thermal image analysis in medicine
Jones, B. F. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.746635 · Cited by 572
Cited by
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Medical applications of infrared thermography: A review
Lahiri, B. B., Bagavathiappan, S., Jayakumar, T., & Philip, J. (2012) · Infrared Physics & Technology · doi:10.1016/j.infrared.2012.03.007 · Cited by 1,333
Infrared Thermography for Temperature Measurement and Non-Destructive Testing
Usamentiaga, R., Venegas, P., Guerediaga, J., Vega, L., Molleda, J., & Bulnes, F. (2014) · Sensors · doi:10.3390/s140712305 · Cited by 1,181
Evolution of Wearable Devices with Real-Time Disease Monitoring for Personalized Healthcare
Guk, K., Han, G., Lim, J., Jeong, K., Kang, T., Lim, E.-K., & Jung, J. (2019) · Nanomaterials · doi:10.3390/nano9060813 · Cited by 624
“It is very important to measure changes in skin temperature during the initial diagnosis and treatment of the disease [80,81].”
BackgroundSERS-Activated Platforms for Immunoassay: Probes, Encoding Methods, and Applications
Wang, Z., Zong, S., Wu, L., Zhu, D., & Cui, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00027 · Cited by 614
Gao, L., Zhang, Y., Malyarchuk, V., Jia, L., Jang, K.-I., Chad Webb, R., Fu, H., Shi, Y., Zhou, G., Shi, L., et al. (2014) · Nature Communications · doi:10.1038/ncomms5938 · Cited by 272
Kandlikar, S. G., Perez-Raya, I., Raghupathi, P. A., Gonzalez-Hernandez, J.-L., Dabydeen, D., Medeiros, L., & Phatak, P. (2017) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2017.01.086 · Cited by 208
“Thermograms of (a) normal breast, (b) with early stages of cancer in the right breast, and (c) advanced cancer in the left breast [34].”
BackgroundA CNN-based methodology for breast cancer diagnosis using thermal images
Zuluaga-Gomez, J., Al Masry, Z., Benaggoune, K., Meraghni, S., & Zerhouni, N. (2021) · Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization · doi:10.1080/21681163.2020.1824685 · Cited by 201
“(Kennedy et al. 2009) make a comparison between breast cancer screening techniques such as thermography, mammography and”
BackgroundBreast thermography from an image processing viewpoint: A survey
Borchartt, T. B., Conci, A., Lima, R. C. F., Resmini, R., & Sanchez, A. (2013) · Signal Processing · doi:10.1016/j.sigpro.2012.08.012 · Cited by 200
“[118] showed that thermography had a sensitivity of only 83% in detecting breast cancer, while the combination of mammography and thermography had a sensitivity of 95%.”
Background
Metadata
- Authors
- Kennedy, D. A., Lee, T., & Seely, D.
- Venue
- Integrative Cancer Therapies
- Publisher
- SAGE Publications
- Published
- 2009-02-17
- Volume
- 8
- Issue
- 1
- Pages
- 9-16
- ISSN
- 1534-7354 (ISSN-L)
- 1552-695X
- OpenAlex
- W2158646588
- Cited by
- 283
- References
- 34
- FWCI
- 7.28
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.