Implant Surface Roughness and Bone Healing: a Systematic Review
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
A systematic review was performed on studies investigating the effects of implant surface roughness on bone response and implant fixation. We searched the literature using MEDLINE from 1953 to 2003. Inclusion criteria were: (1) abstracts of animal studies investigating implant surface roughness and bone healing; (2) observations of three-month bone healing, surface topography measurements, and biomechanical tests; (3) provision of data on surface roughness, bone-to-implant contact, and biomechanical test values. The literature search revealed 5966 abstracts. There were 470, 23, and 14 articles included in the first, second, and third selection steps, respectively. Almost all papers showed an enhanced bone-to-implant contact with increasing surface roughness. Six comparisons were significantly positive for the relationship of bone-to-implant contact and surface roughness. Also, a significant relation was found between push-out strength and surface roughness. Unfortunately, the eventually selected studies were too heterogeneous for inference of data. Nevertheless, the statistical analysis on the available data provided supportive evidence for a positive relationship between bone-to-implant contact and surface roughness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Buser, D., Schenk, R. K., Steinemann, S., Fiorellini, J. P., Fox, C. H., & Stich, H. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250708 · Cited by 1,719
Albrektsson, T. O., & Wennerberg, A. (2004) · PubMed · Cited by 1,118
Suggested guidelines for the topographic evaluation of implant surfaces.
Wennerberg, A., & Albrektsson, T. O. (2000) · PubMed · Cited by 462
Oral implant surfaces: Part 2--review focusing on clinical knowledge of different surfaces.
Albrektsson, T. O., & Wennerberg, A. (2004) · PubMed · Cited by 443
Wennerberg, A. (1996) · Biomaterials · doi:10.1016/0142-9612(96)80750-2 · Cited by 355
A Comparison of Endosseous Dental Implant Surfaces
Cochran, D. L. (1999) · Journal of Periodontology · doi:10.1902/jop.1999.70.12.1523 · Cited by 329
Removal torques for polished and rough titanium implants.
Carlsson, L. V., Röstlund, T., Albrektsson, B., & Albrektsson, T. O. (1988) · PubMed · Cited by 298
Anchorage of TiO2‐blasted, HA‐coated, and machined implants: An experimental study with rabbits
Gotfredson, K., Wennerberg, A., Johansson, C., Skovgaard, L. T., & Hjørting‐Hansen, E. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820291009 · Cited by 284
Dhert, W. J. A., Klein, C. P. A. T., Jansen, J. A., van der Velde, E. A., Vriesde, R. C., Rozing, P. M., & de Groot, K. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270116 · Cited by 179
Self-citationSurvival of hydroxyapatite-coated implants: A meta-analytic review
Lee, J. J., Rouhfar, L., & Beirne, O. R. (2000) · Journal of Oral and Maxillofacial Surgery · doi:10.1053/joms.2000.18269 · Cited by 165
Novaes, A. B., de Souza, S. L. S., de Oliveira, P. T., & Souza, A. M. M. S. (2002) · PubMed · Cited by 142
Vercaigne, S., Wolke, J. C. G., Naert, I., & Jansen, J. A. (2000) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2000.011004314.x · Cited by 108
Self-citationOates, T. W. (2002) · Implant Dentistry · doi:10.1097/00008505-200211040-00051 · Cited by 88
London, R. M., Roberts, F. A., Baker, D. A., Rohrer, M. D., & O'Neal, R. B. (2002) · PubMed · Cited by 72
Vercaigne, S., Wolke, J. G. C., Naert, I. E., & Jansen, J. A. (2000) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2000.011004305.x · Cited by 51
Self-citation
Cited by
Effects of titanium surface topography on bone integration: a systematic review
Wennerberg, A., & Albrektsson, T. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01775.x · Cited by 1,462
Additive manufacturing of fatigue resistant materials: Challenges and opportunities
Yadollahi, A., & Shamsaei, N. (2017) · International Journal of Fatigue · doi:10.1016/j.ijfatigue.2017.01.001 · Cited by 1,023
Advancing dental implant surface technology – From micron- to nanotopography
Mendonça, G., Mendonça, D. B. S., Aragão, F. J. L., & Cooper, L. F. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.05.012 · Cited by 990
Biomaterial strategies for engineering implants for enhanced osseointegration and bone repair
Agarwal, R., & García, A. J. (2015) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.03.013 · Cited by 789
Engineering biocompatible implant surfaces
Bauer, S., Schmuki, P., von der Mark, K., & Park, J. (2013) · Progress in Materials Science · doi:10.1016/j.pmatsci.2012.09.001 · Cited by 780
Metadata
- Authors
- Shalabi, M. M., Gortemaker, A., Hof, M. A. V., Jansen, J. A., & Creugers, N. H. J.
- Venue
- Journal of Dental Research
- Publisher
- SAGE Publications
- Published
- 2006-06
- Volume
- 85
- Issue
- 6
- Pages
- 496-500
- ISSN
- 0022-0345 (ISSN-L)
- 1544-0591
- OpenAlex
- W2149279427
- Cited by
- 531
- References
- 15
- FWCI
- 7.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.