B iocompatibility of D ental C asting A lloys
The DOI matches its Crossref record; 185 of the 185 references it cites were found in a registry or an index.
Abstract
Most cast dental restorations are made from alloys or commercially pure titanium (cpTi). Many orthodontic appliances are also fabricated from metallic materials. It has been documented in vitro and in vivo that metallic dental devices release metal ions, mainly due to corrosion. Those metallic components may be locally and systemically distributed and could play a role in the etiology of oral and systemic pathological conditions. The quality and quantity of the released cations depend upon the type of alloy and various corrosion parameters. No general correlation has been observed between alloy nobility and corrosion. However, it has been documented that some Ni-based alloys, such as beryllium-containing Ni alloys, exhibit increased corrosion, specifically at low pH. Further, microparticles are abraded from metallic restorations due to wear. In sufficient quantities, released metal ions—particularly Cu, Ni, Be, and abraded microparticles—can also induce inflammation of the adjacent periodontal tissues and the oral mucosa. While there is also some in vitro evidence that the immune response can be altered by various metal ions, the role of these ions in oral inflammatory diseases such as gingivitis and periodontitis is unknown. Allergic reactions due to metallic dental restorations have been documented. Ni has especially been identified as being highly allergenic. Interestingly, from 34% to 65.5% of the patients who are allergic to Ni are also allergic to Pd. Further, Pd allergy always occurrs with Ni sensitivity. In contrast, no study has been published which supports the hypothesis that dental metallic materials are mutagenic/genotoxic or might be a carcinogenic hazard to man. Taken together, very contradictory data have been documented regarding the local and systemic effects of dental casting alloys and metallic ions released from them. Therefore, it is of critical importance to elucidate the release of cations from metallic dental restorations in the oral environment and to determine the biological interactions of released metal components with oral and systemic tissues.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Phillips' Science of Dental Materials
Anusavice, K. J. (2013) · Cited by 2,337
(1961) · American Journal of Orthodontics · doi:10.1016/0002-9416(61)90226-3 · Cited by 1,788
Open pore biodegradable matrices formed with gas foaming
Harris, L. D., Kim, B.-S., & Mooney, D. J. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19981205)42:3<396::aid-jbm7>3.0.co;2-e · Cited by 824
Cytotoxicity evaluation of 43 metal salts using murine fibroblasts and osteoblastic cells
Yamamoto, A., Honma, R., & Sumita, M. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199802)39:2<331::aid-jbm22>3.0.co;2-e · Cited by 569
The corrosion behaviour of Ti–6Al–4V, Ti–6Al–7Nb and Ti–13Nb–13Zr in protein solutions
Khan, M. A., Williams, R. L., & Williams, D. F. (1999) · Biomaterials · doi:10.1016/s0142-9612(98)00217-8 · Cited by 485
The carcinogenicity of metals in humans
Hayes, R. B. (1997) · Cancer Causes & Control · doi:10.1023/a:1018457305212 · Cited by 419
Macrophage/particle interactions: Effect of size, composition and surface area
Shanbhag, A. S., Jacobs, J. J., Black, J., Galante, J. O., & Glant, T. T. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820280111 · Cited by 410
Cytotoxic, allergic and genotoxic activity of a nickel-titanium alloy
Wever, D. J., Veldhuizen, A. G., Sanders, M. M., Schakenraad, J. M., & van Horn, J. R. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00041-0 · Cited by 373
Bone resorption activity of particulate-stimulated macrophages
Glant, T. T., Jacobs, J. J., Molnár, G., Shanbhag, A. S., Valyon, M., & Galante, J. O. (1993) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650080907 · Cited by 309
Biological interactions of dental cast alloys with oral tissues
Schmalz, G. (2002) · Dental Materials · doi:10.1016/s0109-5641(01)00063-x · Cited by 308
Research works printed but not linked: 1
- Kappert HF, Kroll M, Schwickerath H (1998). Zellkulturuntersuchungen [Cell culture studies]. In: Verträglichkeit von Dentallegierungen unter besonderer Berücksichtigung "alternativer" Verfahren zur Diagnostik [Compatibility of dental alloys with special reference to "alternative" methods in diagnosis] (in German). Schwickerath H, editor. Cologne, Germany: Deutscher Ärzteverlag, pp. 45-76.
Cited by
Items 301–312 of 312
ElGindy, G. M., Mohamed, H. T., Rizk, F. N., & Sabet, M. E. (2026) · Dental and Medical Problems · doi:10.17219/dmp/177931
CAD/CAM法による硬質レジンクラウンの大臼歯への応用の検討
原田, 章. (2015) · Institutional Repositories DataBase (IRDB)
Vaillant‐Corroy, A. (2019) · theses.fr (ABES) · doi:10.70675/be7018dbzb92ez4b32z9455z46264a16b393
Evaluation of Chronic Gingivitis in Response to Nickel Chromium and Gold Alloy Crown
Mohammadullah, Islam, M. N., Zaki, M., Rahman, T., Rashid, M. I., & Ali, M. I. (2026) · Journal of Paediatric Surgeons of Bangladesh · doi:10.3329/jpsb.v14i1.88461
Pede, D. (2026) · FreiDok plus (Universitätsbibliothek Freiburg) · doi:10.6094/unifr/281612
The physical properties and the antimicrobial activities of boron doped NiMnCoSb shape memory alloys
Abboosh, O., Soyer, P., Kiliç, G., Aydoğdu, A., Tunalı, Y., & Aydogdu, Y. (2026) · Functional Materials Letters · doi:10.1142/s1793604726510252
Effect of diffusion bonding process parameters on microstructure of Ti–Au joint
Likar, P. (2026) · Repository of the University of Ljubljana (University of Ljubljana)
Corrosion and degradation of metals and alloys in dentistry
Hany, R. A., & Rizk, S. (2022) · Biomaterials Journal
Biocompatibility of Orthodontic Materials. A Comprehensive Review
Konda, P., Bangi, S. L., Hridhi Krishna, B., Hussain, M. A., Jain, P., & Mullatti, R. (2026) · Innovative Journal of Medical and Healthcare Research. · doi:10.61808/ijmhr.v3i5.20260008
Dental and protestic factors related to periodontal disease
Rojas, T., Lugo, G., Dávila, L., Yibrín, C., Gimenéz, X., Romero, I., Arteaga, S., Palacios, M., Gutiérrez, R., Infante, J., et al. (2020) · Revista Odontológica de Los Andes
Specialisms and contributions of knowledge to the field
Williams, R. (2012) · Cardiff Metropolitan Research Repository (Cardiff Metropolitan University)
Metadata
- Authors
- Geurtsen, W.
- Affiliations
- Medizinische Hochschule Hannover (DE)
- Corresponding author
- Geurtsen, Werner
- Venue
- Critical Reviews in Oral Biology & Medicine
- Publisher
- SAGE Publications
- Published
- 2002-01
- Volume
- 13
- Issue
- 1
- Pages
- 71-84
- ISSN
- 1045-4411 (ISSN-L)
- 1544-1113
- OpenAlex
- W2024157774
- Cited by
- 221
- References
- 178
- Citations by year
- 2026: 1 · 2025: 6 · 2024: 8 · 2023: 6 · 2022: 8 · 2021: 18 · 2020: 10 · 2019: 5 · 2018: 9 · 2017: 10 · 2016: 12 · 2015: 21 · 2014: 13 · 2013: 14 · 2012: 13
- FWCI
- 3.38
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Critical Reviews in Oral Biology & Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Dentistry › General Dentistry › Dental materials and restorations
- Physical Sciences › Materials Science › Materials Chemistry › Titanium Alloys Microstructure and Properties
- Health Sciences › Medicine › Dermatology › Contact Dermatitis and Allergies
- Keywords
- dental casting alloys, biocompatibility, metal ion release, corrosion, orthodontic appliances, nickel allergy, palladium allergy, periodontal inflammation, gingivitis, periodontitis, genotoxicity, carcinogenicity, commercially pure titanium
- MeSH terms
- Animals, Biocompatible Materials, Cations, Cells, Cultured, Corrosion, Dental Alloys, Dental Casting Technique, DNA Damage, Fibroblasts, Humans, Hypersensitivity, Metals, Neoplasms, Salts, Occupational Exposure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.