B iocompatibility of D ental C asting A lloys
The DOI matches its Crossref record; 185 of the 185 references it cites were found in a registry or an index.
Abstract
Most cast dental restorations are made from alloys or commercially pure titanium (cpTi). Many orthodontic appliances are also fabricated from metallic materials. It has been documented in vitro and in vivo that metallic dental devices release metal ions, mainly due to corrosion. Those metallic components may be locally and systemically distributed and could play a role in the etiology of oral and systemic pathological conditions. The quality and quantity of the released cations depend upon the type of alloy and various corrosion parameters. No general correlation has been observed between alloy nobility and corrosion. However, it has been documented that some Ni-based alloys, such as beryllium-containing Ni alloys, exhibit increased corrosion, specifically at low pH. Further, microparticles are abraded from metallic restorations due to wear. In sufficient quantities, released metal ions—particularly Cu, Ni, Be, and abraded microparticles—can also induce inflammation of the adjacent periodontal tissues and the oral mucosa. While there is also some in vitro evidence that the immune response can be altered by various metal ions, the role of these ions in oral inflammatory diseases such as gingivitis and periodontitis is unknown. Allergic reactions due to metallic dental restorations have been documented. Ni has especially been identified as being highly allergenic. Interestingly, from 34% to 65.5% of the patients who are allergic to Ni are also allergic to Pd. Further, Pd allergy always occurrs with Ni sensitivity. In contrast, no study has been published which supports the hypothesis that dental metallic materials are mutagenic/genotoxic or might be a carcinogenic hazard to man. Taken together, very contradictory data have been documented regarding the local and systemic effects of dental casting alloys and metallic ions released from them. Therefore, it is of critical importance to elucidate the release of cations from metallic dental restorations in the oral environment and to determine the biological interactions of released metal components with oral and systemic tissues.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Phillips' Science of Dental Materials
Anusavice, K. J. (2013) · Cited by 2,337
(1961) · American Journal of Orthodontics · doi:10.1016/0002-9416(61)90226-3 · Cited by 1,788
Open pore biodegradable matrices formed with gas foaming
Harris, L. D., Kim, B.-S., & Mooney, D. J. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19981205)42:3<396::aid-jbm7>3.0.co;2-e · Cited by 824
Cytotoxicity evaluation of 43 metal salts using murine fibroblasts and osteoblastic cells
Yamamoto, A., Honma, R., & Sumita, M. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199802)39:2<331::aid-jbm22>3.0.co;2-e · Cited by 569
The corrosion behaviour of Ti–6Al–4V, Ti–6Al–7Nb and Ti–13Nb–13Zr in protein solutions
Khan, M. A., Williams, R. L., & Williams, D. F. (1999) · Biomaterials · doi:10.1016/s0142-9612(98)00217-8 · Cited by 485
The carcinogenicity of metals in humans
Hayes, R. B. (1997) · Cancer Causes & Control · doi:10.1023/a:1018457305212 · Cited by 419
Macrophage/particle interactions: Effect of size, composition and surface area
Shanbhag, A. S., Jacobs, J. J., Black, J., Galante, J. O., & Glant, T. T. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820280111 · Cited by 410
Cytotoxic, allergic and genotoxic activity of a nickel-titanium alloy
Wever, D. J., Veldhuizen, A. G., Sanders, M. M., Schakenraad, J. M., & van Horn, J. R. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00041-0 · Cited by 373
Bone resorption activity of particulate-stimulated macrophages
Glant, T. T., Jacobs, J. J., Molnár, G., Shanbhag, A. S., Valyon, M., & Galante, J. O. (1993) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650080907 · Cited by 309
Biological interactions of dental cast alloys with oral tissues
Schmalz, G. (2002) · Dental Materials · doi:10.1016/s0109-5641(01)00063-x · Cited by 308
Current aspects in metal genotoxicity
Hartwig, A. (1995) · Biometals · doi:10.1007/bf00156151 · Cited by 253
Effects of metal ions on osteoblast-like cell metabolism and differentiation
Sun, Z. L., Wataha, J. C., & Hanks, C. T. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199701)34:1<29::aid-jbm5>3.0.co;2-p · Cited by 230
Biological effects of palladium and risk of using palladium in dental casting alloys
WATAHA, J. C., & HANKS, C. T. (1996) · Journal of Oral Rehabilitation · doi:10.1111/j.1365-2842.1996.tb00858.x · Cited by 220
Conjoint corrosion and wear in titanium alloys
Khan, M. (1999) · Biomaterials · doi:10.1016/s0142-9612(98)00229-4 · Cited by 211
Wang, J. (1996) · Biomaterials · doi:10.1016/0142-9612(96)00072-5 · Cited by 210
Acute toxicity of metal ions in cultures of osteogenic cells derived from bone marrow stromal cells
Puleo, D. A., & Huh, W. W. (1995) · Journal of Applied Biomaterials · doi:10.1002/jab.770060205 · Cited by 193
Metal release from dental biomaterials
Brune, D. (1986) · Biomaterials · doi:10.1016/0142-9612(86)90097-9 · Cited by 192
Are metals dietary carcinogens?
Rojas, E., Herrera, L. A., Poirier, L. A., & Ostrosky-Wegman, P. (1999) · Mutation Research/Genetic Toxicology and Environmental Mutagenesis · doi:10.1016/s1383-5742(99)00018-6 · Cited by 171
The Release of Elements of Dental Casting Alloys into Cell-culture Medium
Wataha, J. C., Craig, R. G., & Hanks, C. T. (1991) · Journal of Dental Research · doi:10.1177/00220345910700060301 · Cited by 167
Taylor, R. L., Maryan, C. J., & Verran, J. (1998) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(98)70037-x · Cited by 163
Effect of cell line on in vitro metal ion cytotoxicity
Wataha, J. C., Hanks, C. T., & Sun, Z. (1994) · Dental Materials · doi:10.1016/0109-5641(94)90025-6 · Cited by 156
Ability of Ni-containing biomedical alloys to activate monocytes and endothelial cellsin vitro
Wataha, J. C., Lockwood, P. E., Marek, M., & Ghazi, M. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19990605)45:3<251::aid-jbm13>3.0.co;2-5 · Cited by 156
Suppression of Osteoblast Function by Titanium Particles* **
Yao, J., Cs-Szabo, G., Jacobs, J. J., & Kuettner, K. E. (1997) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-199701000-00011 · Cited by 154
Salivary nickel and chromium in subjects with different types of fixed orthodontic appliances
Kerosuo, H., b, G. M., & Hensten‐Pettersen, A. (1997) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/s0889-5406(97)70310-x · Cited by 153
Plasma protein adsorption and platelet adhesion onto comb-like PEO gradient surfaces
Lee, J. H., Jeong, B. J., & Lee, H. B. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199701)34:1<105::aid-jbm14>3.0.co;2-j · Cited by 152
The in vitro effects of metal cations on eukaryotic cell metabolism
Wataha, J. C., Hanks, C. T., & Craig, R. G. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250907 · Cited by 152
A mortality study of workers at seven beryllium processing plants
Ward, E., Okun, A. H., Ruder, A. M., Fingerhut, M. A., & Steenland, K. (1992) · American Journal of Industrial Medicine · doi:10.1002/ajim.4700220610 · Cited by 142
Cellular Response to Metallic Ions Released from Nickel-Chromium Dental Alloys
Bumgardner, J. D., & Lucas, L. C. (1995) · Journal of Dental Research · doi:10.1177/00220345950740081401 · Cited by 134
Genotoxicity of platinum and palladium compounds in human and bacterial cells
Gebel, T., Lantzsch, H., Pleßow, K., & Dunkelberg, H. (1997) · Mutation Research/Genetic Toxicology and Environmental Mutagenesis · doi:10.1016/s1383-5718(96)00145-3 · Cited by 133
Release of elements from dental casting alloys into cell-culture medium over 10 months
Wataha, J. C., & Lockwood, P. E. (1998) · Dental Materials · doi:10.1016/s0109-5641(98)00023-2 · Cited by 132
Transmission electron microscopy of early plaque formation on dental materials in vivo
Hannig, M. (1999) · European Journal of Oral Sciences · doi:10.1046/j.0909-8836.1999.eos107109.x · Cited by 129
Cytotoxicity of Experimental Casting Alloys Evaluated by Cell Culture Tests
Craig, R. G., & Hanks, C. T. (1990) · Journal of Dental Research · doi:10.1177/00220345900690081801 · Cited by 129
Oral manifestations of gold allergy
Laeijendecker, R., & van Joost, T. (1994) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(94)70018-4 · Cited by 128
Hensten‐Pettersen, A. (1992) · Advances in Dental Research · doi:10.1177/08959374920060011401 · Cited by 123
Effect of pH on element release from dental casting alloys
Wataha, J. C., Lockwood, P. E., KHAJOTIA, S. S., & d, R. T. (1998) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(98)70057-5 · Cited by 123
Palladium in dental alloys – the dermatologists’responsibility to warn?
Aberer, W., Holub, H., Strohal, R., & Slavicek, R. (1993) · Contact Dermatitis · doi:10.1111/j.1600-0536.1993.tb03379.x · Cited by 119
Genotoxicity of beryllium, gallium and antimony in short-term assays
Kuroda, K., Endo, G., Okamoto, A., Yoo, Y. S., & Horiguchi, S.-I. (1991) · Mutation Research Letters · doi:10.1016/0165-7992(91)90072-c · Cited by 119
Schroeder, H. A., & Mitchener, M. (1971) · Journal of Nutrition · doi:10.1093/jn/101.10.1431 · Cited by 119
Pacemaker contact sensitivity: Clinical recognition and management
Abdallah, H. I., Balsara, R. K., & O'Riordan, A. C. (1994) · The Annals of Thoracic Surgery · doi:10.1016/0003-4975(94)90228-3 · Cited by 111
Quantization of nickel and beryllium leakage from base metal casting alloys
Covington, J. S., McBride, M. A., Slagle, W. F., & Disney, A. L. (1985) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(85)80087-1 · Cited by 110
Correlation between cytotoxicity and the elements released by dental casting alloys.
Wataha, J. C., MALCOLM, C. T., & Hanks, C. T. (1995) · PubMed · Cited by 107
Streptococcal Adherence on Various Restorative Materials
Satou, J., Fukunaga, A., Satou, N., Shintani, H., & Okuda, K. (1988) · Journal of Dental Research · doi:10.1177/00220345880670031301 · Cited by 103
Thompson, G. J., & Puleo, D. A. (1995) · Journal of Applied Biomaterials · doi:10.1002/jab.770060406 · Cited by 96
Influence of metals on IL-6 release in vitro
Schmalz, G., Schuster, U., & Schweikl, H. (1998) · Biomaterials · doi:10.1016/s0142-9612(98)00075-1 · Cited by 94
Prosthetic Metals Interfere With the Functions of Human Osteoblast Cells In Vitro
Wang, J., Wicklund, B., Gustilo, R. B., & Tsukayama, D. T. (1997) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199706000-00030 · Cited by 91
Mechanisms of cell activation by heavy metal ions
Wagner, M., Klein, C. L., van Kooten, T. G., & Kirkpatrick, C. J. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19981205)42:3<443::aid-jbm14>3.0.co;2-h · Cited by 91
Fishbein, L. (1984) · International Journal of Environmental Analytical Chemistry · doi:10.1080/03067318408079924 · Cited by 89
Effect of dental amalgam and nickel alloys on T-lymphocytes: Preliminary report
Eggleston, D. W. (1984) · Journal of Prosthetic Dentistry · doi:10.1016/0022-3913(84)90404-9 · Cited by 87
Cytotoxicity of Dental Alloy Extracts and Corresponding Metal Salt Solutions
Schmalz, G., Langer, H., & Schweikl, H. (1998) · Journal of Dental Research · doi:10.1177/00220345980770100401 · Cited by 86
Chou, L. L., Firth, J. D., Uitto, V.-J., & Brunette, D. M. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19980305)39:3<437::aid-jbm13>3.0.co;2-7 · Cited by 86
A surface plasmon resonance study of albumin adsorption to PEO-PPO-PEO triblock copolymers
Green, R. J., Davies, M. C., Roberts, C. J., & Tendler, S. J. B. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199811)42:2<165::aid-jbm1>3.0.co;2-n · Cited by 84
In vitro reaction of macrophages to metal ions from dental biomaterials
Wataha, J. C., Hanks, C. T., & Sun, Z. (1995) · Dental Materials · doi:10.1016/0109-5641(95)80056-5 · Cited by 83
Pneumoconiosis and exposures of dental laboratory technicians.
Rom, W. N., Lockey, J. E., Lee, J. S., Kimball, A. C., Bang, K. M., Leaman, H., Johns, R. E., Perrota, D., & Hl, G. (1984) · American Journal of Public Health · doi:10.2105/ajph.74.11.1252 · Cited by 82
Evans, E. J. (1994) · Biomaterials · doi:10.1016/0142-9612(94)90170-8 · Cited by 81
Exposure to cobalt chromium dust and lung disorders in dental technicians.
Seldén, A. I., Persson, B., Bornberger-Dankvardt, S. I., Winstrom, L. E., & Bodin, L. (1995) · Thorax · doi:10.1136/thx.50.7.769 · Cited by 79
Saito, N., Okada, T., Toba, S., Miyamoto, S., & Takaoka, K. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199910)47:1<104::aid-jbm15>3.0.co;2-7 · Cited by 78
Naji, A., & Harmand, M. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820240706 · Cited by 76
Bone-resorbing cytokines in serum of patients with aseptic loosening of hip prostheses
Granchi, D., Verri, E., Ciapetti, G., Stea, S., Savarino, L., Sudanese, A., Mieti, M., Rotini, R., Dallari, D., Zinghi, G., et al. (1998) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.80b5.0800912 · Cited by 76
Toxicity Assessment of 16 Inorganic Environmental Pollutants by Six Bioassays
Sauvant‐Rochat, M., Pépin, D., Bohatier, J., Groliere, C. A., & Guillot, J. (1997) · Ecotoxicology and Environmental Safety · doi:10.1006/eesa.1997.1519 · Cited by 74
Contact sensitivity to nickel and other metals in jewelry reactors
Gawkrodger, D. J., Lewis, F., & Shah, M. (2000) · Journal of the American Academy of Dermatology · doi:10.1067/mjd.2000.107235 · Cited by 73
Messer, R. L. W., & Lucas, L. C. (1999) · Dental Materials · doi:10.1016/s0109-5641(99)90023-4 · Cited by 73
Dental technician's pneumoconiosis. A report of two cases.
Vuyst, P. D., Weyer, R. V., Coster, A. D., Marchandise, F. X., Dumortier, P., Ketelbant, P., Jedwab, J., & Yernault, J. C. (1986) · American Review of Respiratory Disease · doi:10.1164/arrd.1986.133.2.316 · Cited by 69
Effect of titanium on selected oral bacterial species in vitro
Leonhardt, Å., & Dahlén, G. (1995) · European Journal of Oral Sciences · doi:10.1111/j.1600-0722.1995.tb01861.x · Cited by 69
Allergy to palladium in dental alloys
van Ketel, W. G., & Ntebber, C. (1981) · Contact Dermatitis · doi:10.1111/j.1600-0536.1981.tb04092.x · Cited by 69
Epithelium‐fibroblast co‐culture for assessing mucosal irritancy of metals used in dentistry
Schmalz, G., Arenholt‐Bindslev, D., Hiller, K., & Schweikl, H. (1997) · European Journal Of Oral Sciences · doi:10.1111/j.1600-0722.1997.tb00185.x · Cited by 69
In vitro IL-1β and TNF-α release from THP-1 monocytes in response to metal ions
Wataha, J. C., Ratanasathien, S., Hanks, C. T., & Sun, Z. (1996) · Dental Materials · doi:10.1016/s0109-5641(96)80041-8 · Cited by 68
Mechanisms in nickel genotoxicity: the significance of interactions with DNA repair
Hartwig, A., Krüger, I., & Beyersmann, D. (1994) · Toxicology Letters · doi:10.1016/0378-4274(94)90048-5 · Cited by 68
Wataha, J. C., Hanks, C. T., & Craig, R. G. (1992) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820261004 · Cited by 66
Antimicrobial activity of amalgams, alloys and their elements and phases
Morrier, J.-J., Suchett-Kaye, G., Nguyen, V.-D., Rocca, J., Blanc-Benon, J., & Barsotti, O. (1998) · Dental Materials · doi:10.1016/s0109-5641(98)00022-0 · Cited by 66
Spiechowicz, E., Glantz, P. ‐., Axéll, T., & Chmielewski, W. (1984) · Contact Dermatitis · doi:10.1111/j.1600-0536.1984.tb00101.x · Cited by 65
Reaction of fibroblasts to various dental casting alloys
Craig, R. G., & Hanks, C. T. (1988) · Journal of Oral Pathology and Medicine · doi:10.1111/j.1600-0714.1988.tb01547.x · Cited by 65
Occupational lung diseases among dental technicians
Choudat, D. (1994) · Tubercle and Lung Disease · doi:10.1016/0962-8479(94)90037-x · Cited by 63
Penetration of metallic ions from restorations into teeth
Söremark, R., Wing, K. R., Olsson, K. Å., & Goldin, J. (1968) · Journal of Prosthetic Dentistry · doi:10.1016/0022-3913(68)90192-3 · Cited by 63
Corrosion of surgical implants
Traisnel, M., Maguer, D. L., Hildebrand, H. F., & Iost, A. (1990) · Clinical Materials · doi:10.1016/0267-6605(90)90030-y · Cited by 62
Anticoagulant activity of dextran derivatives
de Raucourt, E., Mauray, S., Chaubet, F., Maiga-Revel, O., Jozefowicz, M., & Fischer, A. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199807)41:1<95::aid-jbm12>3.0.co;2-g · Cited by 62
Decreased neutrophil respiratory burst on exposure to cobalt‐chrome alloy and polystyrene in vitro
Shanbhag, A. S., Yang, J. M., Lilien, J. E., & Black, J. (1992) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820260205 · Cited by 61
Labow, R. S., Meek, E., & Santerre, J. P. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19980305)39:3<469::aid-jbm18>3.0.co;2-5 · Cited by 59
Genotoxicity of selected metal compounds in the SOS chromotest
Lantzsch, H., & Gebel, T. (1997) · Mutation Research/Genetic Toxicology and Environmental Mutagenesis · doi:10.1016/s1383-5718(96)00146-5 · Cited by 59
Nickel cobalt and chromium sensitivity in patients with pompholyx (dyshidrotic eczema)
Vien, N. K., & Kaaber, K. (1979) · Contact Dermatitis · doi:10.1111/j.1600-0536.1979.tb04907.x · Cited by 59
Begerow, J., Sensen, U., Wiesmüller, G. A., & Dunemann, L. (1999) · Zentralblatt für Hygiene und Umweltmedizin · doi:10.1016/s0934-8859(99)80006-6 · Cited by 58
Adhesion of periodontal bacteria to titanium, and titanium alloy powders
Steinberg, D., Sela, M. N., Klinger, A., & Kohavi, D. (1998) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.1998.090201.x · Cited by 57
Release of elements from some gold alloys and amalgams in corrosion
Lappalainen, R., & Yli‐Urpo, A. (1987) · European Journal Of Oral Sciences · doi:10.1111/j.1600-0722.1987.tb01854.x · Cited by 57
Cytotoxic effects of cobalt‐chromium alloys on fibroblasts derived from human gingiva
Arvidson, K., Cottler‐Fox, M., HAMMARLUND, E., & Friberg, U. (1987) · European Journal Of Oral Sciences · doi:10.1111/j.1600-0722.1987.tb01853.x · Cited by 56
Bone-resorbing cytokines in serum of patients with aseptic loosening of hip prostheses
Granchi, D., Verri, E., Ciapetti, G., et al. (1998) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.80b5.8513 · Cited by 56
Assad, M., Yahia, L., Rivard, C., & Lemieux, N. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199807)41:1<154::aid-jbm18>3.0.co;2-n · Cited by 56
Wataha, J. C., Nakajima, H., Hanks, C. T., & Okabe, T. H. (1994) · Dental Materials · doi:10.1016/0109-5641(94)90037-x · Cited by 55
Gettleman, L., Cocks, F. H., Darmiento, L., Levine, P. A., Wright, S., & Nathanson, D. (1980) · Journal of Dental Research · doi:10.1177/00220345800590040601 · Cited by 55
Effect of Ni ions on expression of intercellular adhesion molecule 1 by endothelial cells
Wataha, J. C., Sun, Z. L., Hanks, C. T., & Fang, D. N. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199708)36:2<145::aid-jbm2>3.0.co;2-k · Cited by 55
Evaluation of the biocompatibility of various dental alloys: Part I--Toxic potentials.
Kansu, G., & Aydin, A. K. (1996) · PubMed · Cited by 54
Evaluation of titanium in oral conditions and its electrochemical corrosion behaviour
Canay, S., Hersek, N., Çulha, A., & Bilgiç, S. (1998) · Journal of Oral Rehabilitation · doi:10.1046/j.1365-2842.1998.00302.x · Cited by 54
Seldén, A. I., Sahle, W., Johansson, L., Sörenson, S., & Persson, B. (1996) · CHEST Journal · doi:10.1378/chest.109.3.837 · Cited by 54
In vitro investigation into the biological assessment of orthodontic wires
Rose, E. C., Jonas, I. E., & Kappert, H. F. (1998) · Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie · doi:10.1007/bf01321792 · Cited by 54
Corrosion and cell culture evaluations of nickel‐chromium dental casting alloys
Bumgardner, J. D., & Lucas, L. C. (1994) · Journal of Applied Biomaterials · doi:10.1002/jab.770050305 · Cited by 53
Begerow, J. (1999) · Biomarkers · doi:10.1080/135475099230976 · Cited by 52
Cytotoxicity of Metal Cations used in Dental Cast Alloys
Schmalz, G., Arenholt‐Bindslev, D., Pfüller, S., & Schweikl, H. (1997) · Alternatives to Laboratory Animals · doi:10.1177/026119299702500313 · Cited by 52
Prabhu, A., Shelburne, C. E., & Gibbons, D. F. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19981215)42:4<517::aid-jbm6>3.0.co;2-u · Cited by 51
Tomakidi, P., Koke, U., Kern, R., Erdinger, L., Krüger, H., Kohl, A., & Komposch, G. (2000) · Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie · doi:10.1007/bf02340928 · Cited by 51
Prabhu, A., Shelburne, C. E., & Gibbons, D. F. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19981215)42:4<655::aid-jbm23>3.0.co;2-b · Cited by 51
In vitro evaluation of biocompatibility of experimental titanium alloys for dental restorations
Wang, R. R., & Li, Y. (1998) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(98)70018-6 · Cited by 50
Fluorescent microplate assay for respiratory burst of PMNs challengedin vitro with orthopedic metals
Ciapetti, G., Granchi, D., Verri, E., Savarino, L., Cenni, E., Savioli, F., & Pizzoferrato, A. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19980905)41:3<455::aid-jbm15>3.0.co;2-h · Cited by 50
Lipopolysaccharide affinity for titanium implant biomaterials
Nelson, S. K., Knoernschild, K. L., Robinson, F. G., & Schuster, G. S. (1997) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(97)70210-5 · Cited by 49
Human cell culture studies with dental metallic materials
Berstein, A., Bemauer, I., Marx, R., & Geurtsen, W. (1992) · Biomaterials · doi:10.1016/0142-9612(92)90002-6 · Cited by 48
Self-citationBumgardner, J. D., Doeller, J. E., & Lucas, L. C. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820290508 · Cited by 47
Bumgardner, J. D., Lucas, L. C., & Tilden, A. B. (1989) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820231002 · Cited by 47
Klein, C. L., Nieder, P., Wagner, M., K�hler, H., Bittinger, F., Kirkpatrick, C. J., & Lewis, J. C. (1994) · Journal of Materials Science Materials in Medicine · doi:10.1007/bf00213138 · Cited by 47
Cancer hazards caused by nickel and chromium exposure
Norseth, T. (1980) · Journal of Toxicology and Environmental Health · doi:10.1080/15287398009529940 · Cited by 45
Effect of alloy surface composition on release of elements from dental casting alloys
Wataha, J. C., & MALCOLM, C. T. (1996) · Journal of Oral Rehabilitation · doi:10.1046/j.1365-2842.1996.d01-204.x · Cited by 45
Effect of prosthetic titanium wear debris on mitogen-induced monocyte and lymphoid activation
Kohilas, K., Lyons, M., Lofthouse, R. A., Frondoza, C. G., Jinnah, R. H., & Hungerford, D. S. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199910)47:1<95::aid-jbm14>3.0.co;2-8 · Cited by 44
Mutagenicity, carcinogenicity and teratogenicity of beryllium
Léonard, A., & Lauwerys, R. (1987) · Mutation Research/Reviews in Genetic Toxicology · doi:10.1016/0165-1110(87)90013-3 · Cited by 43
The effect of metals on IL-2-related lymphocyte proliferation
Warner, G. L., & Lawrence, D. A. (1988) · International Journal of Immunopharmacology · doi:10.1016/0192-0561(88)90082-3 · Cited by 43
Accelerated toxicity testing of casting alloys and reduction of intraoral release of elements
Nelson, S. K., Wataha, J. C., & Lockwoodc, P. E. (1999) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(99)70112-5 · Cited by 43
Pneumoconiosis among Cretan Dental Technicians
Froudarakis, Μ. E., Voloudaki, A. E., Bouros, D. E., Drakonakis, G., Hatzakis, K., & Siafakas, N. M. (1999) · Respiration · doi:10.1159/000029404 · Cited by 42
Test battery for metal allergy in dentistry
van Loon, L. A. J., van Elsas, P. W., van Joost, T., & Davidson, C. L. (1986) · Contact Dermatitis · doi:10.1111/j.1600-0536.1986.tb01196.x · Cited by 42
Morais, S., Sousa, J. P., Fernandes, M. H., de Carvalho, G. S., de Bruijn, J. D., & van Blitterswijk, C. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199811)42:2<199::aid-jbm5>3.0.co;2-k · Cited by 42
Geis‐Gerstorfer, J., & Pässler, K. (1993) · Dental Materials · doi:10.1016/0109-5641(93)90117-9 · Cited by 41
Cytotoxic and antibacterial effects of orthodontic appliances
Grímsdóttir, M. R., & Hensten‐Pettersen, A. (1993) · European Journal Of Oral Sciences · doi:10.1111/j.1600-0722.1993.tb01110.x · Cited by 41
Indium and iridium allergy in patients exposed to dental alloys
Marcusson, J. A., Cederbrant, K., & Heilborn, J. D. (1998) · Contact Dermatitis · doi:10.1111/j.1600-0536.1998.tb05758.x · Cited by 41
The prevalence of sensitivity to constituents of dental alloys
Namikoshi, T., Yoshimatsu, T., SUGA, K., Fujii, H., & Yasuda, K. (1990) · Journal of Oral Rehabilitation · doi:10.1111/j.1365-2842.1990.tb00022.x · Cited by 41
In vitro cytotoxicity of Ag‐Pd‐Cu‐based casting alloys
Niemi, L., & Hensten‐Pettersen, A. (1985) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820190507 · Cited by 41
Immunomodulation of in vitro antigen presentation by cations
Smith, K. L., & Lawrence, D. A. (1988) · Toxicology and Applied Pharmacology · doi:10.1016/0041-008x(88)90007-5 · Cited by 39
Cytotoxicity of dental casting alloys pretreated with biologic solutions
Nelson, S. K., Wataha, J. C., Neme, A.-M. L., Cibirka, R., & Lockwood, P. E. (1999) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(99)70215-5 · Cited by 39
Initial versus subsequent release of elements from dental casting alloys
Wataha, J. C., Lockwood, P. E., & Nelson, S. K. (1999) · Journal of Oral Rehabilitation · doi:10.1046/j.1365-2842.1999.00455.x · Cited by 39
[Crown and restoration margins].
Geurtsen, W. (1990) · PubMed · Cited by 38
Self-citationMineralogy of Lung Tissue in Dental Laboratory Technicians' Pneumoconiosis
Nayebzadeh, A., Dufresne, A., Harvie, S., & Begin, R. O. (1999) · American Industrial Hygiene Association Journal · doi:10.1080/00028899908984452 · Cited by 38
In vitro plaque formation on commonly used dental materials
DUMMER, P. M. H., & HARRISON, K. A. (1982) · Journal of Oral Rehabilitation · doi:10.1111/j.1365-2842.1982.tb01030.x · Cited by 38
Joshi, R., & Eley, A. (1988) · Journal of Medical Microbiology · doi:10.1099/00222615-27-2-105 · Cited by 38
Studies on the genotoxicity of beryllium sulphate in vitro and in vivo
Ashby, J., Ishidate, M., Stoner, G. D., Morgan, M. A. M., Ratpan, F., & Callander, R. D. (1990) · Mutation Research/Genetic Toxicology · doi:10.1016/0165-1218(90)90061-6 · Cited by 37
Apparent Cytotoxicity of Base Metal Casting Alloys
Woody, R. D., Huget, E. F., & Horton, J. E. (1977) · Journal of Dental Research · doi:10.1177/00220345770560070601 · Cited by 36
Morris, H. F. (1987) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(87)80132-4 · Cited by 35
Evaluation of the biocompatibility of various dental alloys: Part 2--Allergenical potentials.
Kansu, G., & Aydin, A. K. (1996) · PubMed · Cited by 35
Long-term cytotoxicity of dental casting alloys.
Wataha, J. C., Lockwood, P. E., Nelson, S. K., & Bouillaguet, S. (1999) · PubMed · Cited by 35
Proliferation of nickel-sensitive human lymphocytes by corrosion products of orthodontic appliances
Grímsdóttir, M. R., Hensten‐Pettersen, A., & Kullmann, A. (1994) · Biomaterials · doi:10.1016/0142-9612(94)90236-4 · Cited by 34
Rebandel, P., & RUDZKI, E. (1990) · Contact Dermatitis · doi:10.1111/j.1600-0536.1990.tb03241.x · Cited by 32
Hanssen, H. H. L., Wetzels, G. M. R., Benzina, A., van der Veen, F. H., Lindhout, T., & Koole, L. H. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(1999)48:6<797::aid-jbm6>3.0.co;2-4 · Cited by 32
Nordlind, K. (2009) · International Archives of Allergy and Applied Immunology · doi:10.1159/000233947 · Cited by 32
Allergic contact gingivostomatitis due to gold
Izumi, A. K. (1982) · Archives of Dermatological Research · doi:10.1007/bf00509070 · Cited by 31
Klein, C. L., Köhler, H., & Kirkpatrick, C. J. (2008) · Pathobiology · doi:10.1159/000163883 · Cited by 31
Takei, I., Takagi, M., Santavirta, S. S., Ida, H., Hamasaki, M., Ishii, M., Fukushima, S., Ogino, T., & Konttinen, Y. T. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19990605)45:3<175::aid-jbm3>3.0.co;2-9 · Cited by 30
Carcinogenicity of beryllium hydroxide and alloys
Groth, D. H., Kommineni, C., & Mackay, G. R. (1980) · Environmental Research · doi:10.1016/0013-9351(80)90009-2 · Cited by 30
Thin sol-gel-derived silica coatings on dental pure titanium casting
Yoshida, K., Kamada, K., Sato, K., Hatada, R., Baba, K., & Atsuta, M. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(1999)48:6<778::aid-jbm3>3.0.co;2-c · Cited by 29
Bumgardner, J. D., Lucas, L. C., Alverson, M. W., & Tilden, A. B. (1993) · Dental Materials · doi:10.1016/0109-5641(93)90080-a · Cited by 28
Locci, P., Becchetti, E., Pugliese, M., Rossi, L., Lilli, C., Calvitti, M., & Staffolani, N. (1996) · Journal of Periodontology · doi:10.1902/jop.1996.67.12.1260 · Cited by 27
A long-term follow-up of allergy to nickel among fixed prostheses wearers.
Spiechowicz, E., Glantz, P. ‐., Axéll, T., & Grochowski, P. (1999) · PubMed · Cited by 27
In vitro cytotoxicity of dental casting alloys over 8 months
Wataha, J. C., Lockwood, P. E., Nelson, S. K., & Rakich, D. R. (1999) · Journal of Oral Rehabilitation · doi:10.1046/j.1365-2842.1999.00398.x · Cited by 25
Reuling, N., Wisser, W., Jung, A., & Denschlag, H. O. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820240802 · Cited by 24
Contact allergy to dental materials in patients with orofacial complaints
Yontchev, E., Meding, B., & HEDEGÅRD, B. (1986) · Journal of Oral Rehabilitation · doi:10.1111/j.1365-2842.1986.tb00650.x · Cited by 24
Epple, M., & Herzberg, O. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199822)43:2<153::aid-jbm9>3.0.co;2-n · Cited by 24
The biocompatibility of a dental Ag‐Pd‐Cu‐Au‐based casting alloy and its structural components
Niemi, L., Syrjänen, S., & Hensten‐Pettersen, A. (1985) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820190506 · Cited by 24
[Studies on the allergenic potential of palladium alloys].
Augthun, M., Lichtenstein, M., & Kammerer, G. (1990) · PubMed · Cited by 23
In vitro Toxicity of Cobalt and Hard Metal Dust in Rat and Human Type II Pneumocytes
Roesems, G., Hoet, P., DEMEDTS, M. G., & Nemery, B. (1997) · Pharmacology & Toxicology · doi:10.1111/j.1600-0773.1997.tb00034.x · Cited by 22
A new method for intraoral patch testing
Axéll, T., Spiechowicz, E., Glantz, P. ‐., Andersson, G., & Larsson, A. (1986) · Contact Dermatitis · doi:10.1111/j.1600-0536.1986.tb01276.x · Cited by 21
Soft tissue response to implants of gallium alloys and silver amalgam alloys
Lyon, H. W., Waterstrat, R. M., & Paffenbarger, G. C. (1966) · The Journal of the American Dental Association · doi:10.14219/jada.archive.1966.0075 · Cited by 19
Endotoxin adherence to and elution from two casting alloys.
Knoernschild, K. L., Lefebvre, C. A., Schuster, G. S., Payant, L., & Gagnon, F. (1994) · PubMed · Cited by 19
Human brain tumors and exposure to metal and non-metal elements: a case-control study.
Hadfield, M. G., Adera, T., Smith, B., Fortner-Burton, C. A., Gibb, R., & Mumaw, V. R. (1998) · PubMed · Cited by 18
Use of low fusing alloy in dentistry
Wee, A. G., Schneider, R. L., & Aquilino, S. A. (1998) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(98)70029-0 · Cited by 17
IgA Nephropathy Associated with Dental Nickel Alloy Sensitization
Strauss, F. G., & Eggleston, D. W. (2008) · American Journal of Nephrology · doi:10.1159/000166973 · Cited by 17
Effect of treatment concentration on lipopolysaccharide affinity for two alloys
Knoernschild, K. L., Tompkins, G. R., Schuster, G. S., Lefebvre, C. A., & Russell, C. M. (1997) · Dental Materials · doi:10.1016/s0109-5641(97)80020-6 · Cited by 16
Latinwo, L. M., Ikediobi, C. O., Singh, N. P., Sponholtz, G., Fasanya-Odewumi, C., & Riley, L. (1997) · PubMed · Cited by 16
The clinical significance of beryllium.
Aj, A. (1990) · Journal of trace elements and electrolytes in health and disease · Cited by 16
Effects of titanium-dental restorative alloy galvanic couples on cultured cells
Bumgardner, J. D., & Johansson, B. I. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199822)43:2<184::aid-jbm13>3.0.co;2-i · Cited by 16
[Non-precious metal dental alloys and allergy].
Hildebrand, H. F., Veron, C., & de Martin, P. (1989) · PubMed · Cited by 15
Mutagenicity of cadmium, platinum and rhodium compounds in cultured mammalian cells.
Kanematsu, N., Nakamine, H., Fukuta, Y., Yasuda, J., Kurenuma, S., & Shibata, K. I. (1990) · PubMed · Cited by 15
Evaluation of tissue response to dental alloys by subcutaneous implantation
Bessing, C., & Kallus, T. (1987) · Acta Odontologica Scandinavica · doi:10.3109/00016358709097537 · Cited by 15
Biocompatibility evaluation of casting alloys in hamsters
Piliero, S. J., Carson, S., LiCalzi, M., Pentel, L., Piliero, J. A., Kaufman, E. G., Schulman, A., & Willigan, D. A. (1979) · Journal of Prosthetic Dentistry · doi:10.1016/0022-3913(79)90311-1 · Cited by 14
ARIKAN, A. (1992) · Journal of Oral Rehabilitation · doi:10.1111/j.1365-2842.1992.tb01576.x · Cited by 14
[Complex pneumoconiosis in dental laboratory technicians].
Carlès, P., Fabre, J.-B., Pujol, M., Duprez, A., & Bollinelli, R. (1978) · PubMed · Cited by 14
Dental-technicians Pneumoconiosis - a Report of 2 Cases
Devuyst, P., Vandeweyer, R., Decoster, A., et al. (1986) · Digital Access to Libraries · Cited by 14
Human neutrophil response to short‐term exposure to F‐75 cobalt‐based alloy
Yang, J. M., Shanbhag, A. S., Lilien, J. E., & Black, J. (1992) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820260911 · Cited by 13
Effect of dental base metal alloys on IgE levels and some blood parameters
KULAK, Y., & ARIKAN, A. (1997) · Journal of Oral Rehabilitation · doi:10.1046/j.1365-2842.1997.00549.x · Cited by 10
Preferential affinity of oral bacteria for homologous salivary films on dental materials
Ósrstavik, J., Ósrstavik, D., & Kommisar, J. (1982) · Acta Odontologica Scandinavica · doi:10.3109/00016358209019809 · Cited by 10
Kouamé, P., Bellis, G., Tebbi, A., Gaimard, M., Dilumbu, I., Assouan, A. D., Roux, F., Mayer, G., Chastin, I., Diarra, N., et al. (1998) · PubMed · Cited by 10
[Solubility of dental alloys].
Schwickerath, H. (1988) · PubMed · Cited by 8
[Solubility of dental alloys in saliva].
Pfeiffer, P., & Schwickerath, H. (1989) · PubMed · Cited by 8
Porphyromonas gingivalis lipopolysaccharide affinity for two casting alloys
Knoernschild, K. L., Tompkins, G. R., Lefebvre, C. A., & Schuster, G. S. (1995) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(05)80225-2 · Cited by 7
[Histomorphometrical studies on the histocompatibility of dental alloys].
Reuling, N., Pohl-Reuling, B., & Keil, M. (1991) · PubMed · Cited by 7
[Use of titanium in conservative dentistry].
Geurtsen, W., & Marx, R. (1990) · PubMed · Cited by 7
Self-citationBataille, L., Judas, D., Rocher, P., Laffargue, P., Lecomte-Houcke, M., Iost, A., Lefèvre, A., & Hildebrand, H. F. (1997) · PubMed · Cited by 6
[In vivo corrosion studies of gold-containing alloys].
Kratzenstein, B., Sauer, K., Weber, H., & Geis‐Gerstorfer, J. (1986) · PubMed · Cited by 6
Prevalence of Gold Sensitivity in Asymptomatic Individuals with Gold Dental Restorations
Schaffran, R. M., Storrs, F. J., & Schalock, P. C. (1999) · Dermatitis · doi:10.1097/01206501-199912000-00004 · Cited by 6
Cytotoxicity of Au-based dental solders alone and on a substrate alloy
Wataha, J. C., Lockwood, P. E., Vuill�me, M. N., & Z�rcher, M.-H. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(1999)48:6<786::aid-jbm4>3.0.co;2-e · Cited by 5
In vivo corrosion phenomena of cast restorations and their interactions with the oral cavity
Kratzenstein, B., Sauer, K., & Weber, H. (1989) · Journal of Dentistry · doi:10.1016/0300-5712(89)90186-3 · Cited by 4
[Nickel release of dental alloys as a function of the pH value of the corrosive solution].
Pfeiffer, P., & Schwickerath, H. (1991) · PubMed · Cited by 3
The effect of dental alloys on mouse lymphocyte subpopulations
Zalkind, Calderon, Rabinowitz, Hadar, & Schlesinger (1998) · Journal of Oral Rehabilitation · doi:10.1046/j.1365-2842.1998.00212.x · Cited by 2
(1988) · Anaesthesia · doi:10.1111/j.1365-2044.1988.tb09003.x · Cited by 1
Lu (1999) · doi:10.1002/(sici)1097-4636(199908)46:2
Research works printed but not linked: 2
- Kappert HF, Kroll M, Schwickerath H (1998). Zellkulturuntersuchungen [Cell culture studies]. In: Verträglichkeit von Dentallegierungen unter besonderer Berücksichtigung "alternativer" Verfahren zur Diagnostik [Compatibility of dental alloys with special reference to "alternative" methods in diagnosis] (in German). Schwickerath H, editor. Cologne, Germany: Deutscher Ärzteverlag, pp. 45-76.
- 10.1002/(sici)1097-4636(199908)46:2<221::aid-jbm11>3.0.co;2-t · doi:10.1002/(sici)1097-4636(199908)46:2<221::aid-jbm11>3.0.co;2-t
Cited by
In vitro corrosion and biocompatibility of binary magnesium alloys
Gu, X., Zheng, Y., Cheng, Y., Zhong, S., & Xi, T. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.10.021 · Cited by 1,343
A new look at biomedical Ti-based shape memory alloys
Biesiekierski, A., Wang, J., Gepreel, M. A.-H., & Wen, C. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.01.018 · Cited by 719
Design strategy for biodegradable Fe-based alloys for medical applications☆
Schinhammer, M., Hänzi, A. C., Löffler, J. F., & Uggowitzer, P. J. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.07.039 · Cited by 578
Ding, Y., Wen, C., Hodgson, P., & Li, Y. (2014) · J. Mater. Chem. B · doi:10.1039/c3tb21746a · Cited by 531
Mg–Zr–Sr alloys as biodegradable implant materials
Li, Y., Wen, C., Mushahary, D., Sravanthi, R., Harishankar, N., Pande, G., & Hodgson, P. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.04.028 · Cited by 309
Metadata
- Authors
- Geurtsen, W.
- Affiliations
- Medizinische Hochschule Hannover (DE)
- Corresponding author
- Geurtsen, Werner
- Venue
- Critical Reviews in Oral Biology & Medicine
- Publisher
- SAGE Publications
- Published
- 2002-01
- Volume
- 13
- Issue
- 1
- Pages
- 71-84
- ISSN
- 1045-4411 (ISSN-L)
- 1544-1113
- OpenAlex
- W2024157774
- Cited by
- 221
- References
- 178
- Citations by year
- 2026: 1 · 2025: 6 · 2024: 8 · 2023: 6 · 2022: 8 · 2021: 18 · 2020: 10 · 2019: 5 · 2018: 9 · 2017: 10 · 2016: 12 · 2015: 21 · 2014: 13 · 2013: 14 · 2012: 13
- FWCI
- 3.38
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Critical Reviews in Oral Biology & Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Dentistry › General Dentistry › Dental materials and restorations
- Physical Sciences › Materials Science › Materials Chemistry › Titanium Alloys Microstructure and Properties
- Health Sciences › Medicine › Dermatology › Contact Dermatitis and Allergies
- Keywords
- dental casting alloys, biocompatibility, metal ion release, corrosion, orthodontic appliances, nickel allergy, palladium allergy, periodontal inflammation, gingivitis, periodontitis, genotoxicity, carcinogenicity, commercially pure titanium
- MeSH terms
- Animals, Biocompatible Materials, Cations, Cells, Cultured, Corrosion, Dental Alloys, Dental Casting Technique, DNA Damage, Fibroblasts, Humans, Hypersensitivity, Metals, Neoplasms, Salts, Occupational Exposure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.