CoChat

Evidence-Based Evaluation of Diagnostic Accuracy of Resting EEG in Dementia and Mild Cognitive Impairment

Jelic, Vesna, Kowalski, Jan · 2009 · Clinical EEG and Neuroscience
Cited by 105

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

Cognitive impairment is the most frequent chronic condition in the elderly, and dementia is the most disabling form of cognitive impairment in elderly. In the absence of specific and reliable markers of etiologically different dementia syndromes and their preclinical stages, diagnosis in living patients is probabilistic and based on standardized clinical diagnostic criteria. There is still not enough information on the validity of the EEG method in dementia work-up, and an updated evidence-based consensus on appropriateness of this method in the initial evaluation of patients with suspected cognitive disorder and dementia is missing. Using an evidence-based technique we searched for articles on diagnostic accuracy of spontaneous EEG in dementia disorders published from 1980 until June 2008. Inclusion criteria were: original article published in English with 10 or more subjects per diagnostic group, diagnosed according to the established consensus clinical diagnostic criteria used as a “gold standard.” In addition, it should have been possible to calculate from the reported results indexes of diagnostic test accuracy: sensitivity, specificity, likelihood ratios and diagnostic odds ratios. Forty-six articles were retrieved that satisfied eligibility criteria. Thirty-four (74%) studies employed case-control design where study population was recruited from consecutive patients at specialist clinic settings, 12 (26%) were prospective in terms of reported clinical follow-up of study population. Four (9%) studies used population-based samples and 5 (11%) studies stated in methods the recruitment procedures for patients and healthy subjects. Number of patients included in diagnostic groups and healthy subjects varied in included studies between 10 and 180 and 10 and 171, respectively. Figures on sensitivity and specificity across the studies varied widely. Positive likelihood ratio in studies reporting classification accuracies between Alzheimer's disease and controls ranged between 2.3 and 38.5, and diagnostic odds ratios consequently showed large variations between 7 and 219. In conclusion, despite the wealth of published research and reported high indexes of diagnostic accuracy of EEG, and qEEG in particular, in individual studies, evidence of diagnostic utility of resting EEG in dementia and mild cognitive impairment (MCI) is still not sufficient to establish this method for the initial evaluation of subjects with cognitive impairment in the routine clinical practice. Joint effort of preferably multicenter studies using uniform standards should develop optimized methods, investigate added diagnostic value of EEG in clinically established dementia diagnosis and predictive utility of EEG in MCI and questionable dementia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/155005940904000211

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 105

Metadata

Authors
Jelic, V., & Kowalski, J.
Venue
Clinical EEG and Neuroscience
Published
2009-04
Volume
40
Issue
2
Pages
129-142
ISSN
  • 1550-0594 (ISSN-L)
  • 2169-5202
OpenAlex
W2042110902
Cited by
105
References
14
FWCI
5.91
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.