A Randomized Controlled Trial of EEG-Based Motor Imagery Brain-Computer Interface Robotic Rehabilitation for Stroke
The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
Electroencephalography (EEG)–based motor imagery (MI) brain-computer interface (BCI) technology has the potential to restore motor function by inducing activity-dependent brain plasticity. The purpose of this study was to investigate the efficacy of an EEG-based MI BCI system coupled with MIT-Manus shoulder-elbow robotic feedback (BCI-Manus) for subjects with chronic stroke with upper-limb hemiparesis. In this single-blind, randomized trial, 26 hemiplegic subjects (Fugl-Meyer Assessment of Motor Recovery After Stroke [FMMA] score, 4-40; 16 men; mean age, 51.4 years; mean stroke duration, 297.4 days), prescreened with the ability to use the MI BCI, were randomly allocated to BCI-Manus or Manus therapy, lasting 18 hours over 4 weeks. Efficacy was measured using upper-extremity FMMA scores at weeks 0, 2, 4 and 12. ElEG data from subjects allocated to BCI-Manus were quantified using the revised brain symmetry index (rBSI) and analyzed for correlation with the improvements in FMMA score. Eleven and 15 subjects underwent BCI-Manus and Manus therapy, respectively. One subject in the Manus group dropped out. Mean total FMMA scores at weeks 0, 2, 4, and 12 weeks improved for both groups: 26.3 ± 10.3, 27.4 ± 12.0, 30.8 ± 13.8, and 31.5 ± 13.5 for BCI-Manus and 26.6 ± 18.9, 29.9 ± 20.6, 32.9 ± 21.4, and 33.9 ± 20.2 for Manus, with no intergroup differences ( P = .51). More subjects attained further gains in FMMA scores at week 12 from BCI-Manus (7 of 11 [63.6%]) than Manus (5 of 14 [35.7%]). A negative correlation was found between the rBSI and FMMA score improvement ( P = .044). BCI-Manus therapy was well tolerated and not associated with adverse events. In conclusion, BCI-Manus therapy is effective and safe for arm rehabilitation after severe poststroke hemiparesis. Motor gains were comparable to those attained with intensive robotic therapy (1,040 repetitions/session) despite reduced arm exercise repetitions using EEG-based MI-triggered robotic feedback (136 repetitions/session). The correlation of rBSI with motor improvements suggests that the rBSI can be used as a prognostic measure for BCI-based stroke rehabilitation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The post-stroke hemiplegic patient. 1. a method for evaluation of physical performance
Fugl-Meyer, A., Jääskö, L., Leyman, I., Olsson, S., & Steglind, S. (1975) · Journal of Rehabilitation Medicine · doi:10.2340/1650197771331 · Cited by 5,564
Interrater Reliability of a Modified Ashworth Scale of Muscle Spasticity
Bohannon, R. W., & Smith, M. B. (1987) · Physical Therapy · doi:10.1093/ptj/67.2.206 · Cited by 5,424
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Optimal spatial filtering of single trial EEG during imagined hand movement
Ramoser, H., Muller-Gerking, J., & Pfurtscheller, G. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.895946 · Cited by 2,457
Motor recovery after stroke: a systematic review
Langhorne, P., Coupar, F., & Pollock, A. (2009) · The Lancet Neurology · doi:10.1016/s1474-4422(09)70150-4 · Cited by 2,319
Mu rhythm (de)synchronization and EEG single-trial classification of different motor imagery tasks
Pfurtscheller, G., Brunner, C., Schlögl, A., & Lopes da Silva, F. H. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.12.003 · Cited by 1,587
Robot-aided neurorehabilitation
Krebs, H. I., Hogan, N., Aisen, M. L., & Volpe, B. T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.662623 · Cited by 1,425
Robot-Assisted Therapy for Long-Term Upper-Limb Impairment after Stroke
Lo, A. C., Guarino, P. D., Richards, L. G., Haselkorn, J. K., Wittenberg, G. F., Federman, D. G., Ringer, R. J., Wagner, T. H., Krebs, H. I., Volpe, B. T., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa0911341 · Cited by 1,397 · cited 1×
“88 points after 36 weeks.(35) This study yielded FMMA score increases of approximately +6.”
BackgroundFilter Bank Common Spatial Pattern Algorithm on BCI Competition IV Datasets 2a and 2b
Ang, K. K., Chin, Z. Y., Wang, C., Guan, C., & Zhang, H. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00039 · Cited by 1,264
Self-citationBrain–computer interfaces in neurological rehabilitation
Daly, J. J., & Wolpaw, J. R. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70223-0 · Cited by 1,149 · cited 1×
“(ERS), which are detectable on EEG during MI in healthy subjects.(4,10-13) Recent studies have also revealed that ERD and ERS can be enhanced using BCI with proprioceptive feedback(14) or haptic feedback by closing the sensorimotor loop.”
Background
Cited by
A review of feature selection methods in medical applications
Remeseiro, B., & Bolon-Canedo, V. (2019) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2019.103375 · Cited by 804
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
EEG-Based Brain-Computer Interfaces Using Motor-Imagery: Techniques and Challenges
Padfield, N., Zabalza, J., Zhao, H., Masero, V., & Ren, J. (2019) · Sensors · doi:10.3390/s19061423 · Cited by 596
Brain‐computer interfaces for post‐stroke motor rehabilitation: a meta‐analysis
Cervera, M. A., Soekadar, S. R., Ushiba, J., Millán, J. D. R., Liu, M., Birbaumer, N., & Garipelli, G. (2018) · Annals of Clinical and Translational Neurology · doi:10.1002/acn3.544 · Cited by 572
A decade retrospective of medical robotics research from 2010 to 2020
Dupont, P. E., Nelson, B. J., Goldfarb, M., Hannaford, B., Menciassi, A., O’Malley, M. K., Simaan, N., Valdastri, P., & Yang, G.-Z. (2021) · Science Robotics · doi:10.1126/scirobotics.abi8017 · Cited by 516
BCI for stroke rehabilitation: motor and beyond
Mane, R., Chouhan, T., & Guan, C. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/aba162 · Cited by 466
Self-citationFrolov, A. A., Mokienko, O., Lyukmanov, R., Biryukova, E., Kotov, S., Turbina, L., Nadareyshvily, G., & Bushkova, Y. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00400 · Cited by 396
Novel Stroke Therapeutics: Unraveling Stroke Pathophysiology and Its Impact on Clinical Treatments
George, P. M., & Steinberg, G. K. (2015) · Neuron · doi:10.1016/j.neuron.2015.05.041 · Cited by 393
Ang, K. K., Guan, C., Phua, K. S., Wang, C., Zhou, L., Tang, K. Y., Ephraim Joseph, G. J., Kuah, C. W. K., & Chua, K. S. G. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00030 · Cited by 361
Self-citationBrain–machine interfaces in neurorehabilitation of stroke
Soekadar, S. R., Birbaumer, N., Slutzky, M. W., & Cohen, L. G. (2015) · Neurobiology of Disease · doi:10.1016/j.nbd.2014.11.025 · Cited by 335
Bundy, D. T., Souders, L., Baranyai, K., Leonard, L., Schalk, G., Coker, R., Moran, D. W., Huskey, T., & Leuthardt, E. C. (2017) · Stroke · doi:10.1161/strokeaha.116.016304 · Cited by 242
“This included (1) donning the exoskeleton and EEG cap, (2) examining the EEG readouts to verify that physiological signals were collected, (3) software operation, and (4) system maintenance.”
MethodFoong, R., Ang, K. K., Quek, C., Guan, C., Phua, K. S., Kuah, C. W. K., Deshmukh, V. A., Yam, L. H. L., Rajeswaran, D. K., Tang, N., et al. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2921198 · Cited by 196
Self-citationHand Rehabilitation Robotics on Poststroke Motor Recovery
Yue, Z., Zhang, X., & Wang, J. (2017) · Behavioural Neurology · doi:10.1155/2017/3908135 · Cited by 195
“conducted many experiments and verified that there are great possibilities for stroke patients to evoke the MI-BCI, thus making the application of MI-BCI possible [141, 142].”
BackgroundEEG-based BCI and video games: a progress report
Kerous, B., Skola, F., & Liarokapis, F. (2018) · Virtual Reality · doi:10.1007/s10055-017-0328-x · Cited by 179
“Indeed, one of the main roles for games controlled by MI-BCIs nowadays is providing restoration of movement in patients suffering from neurological conditions such as post-stroke state (Ang et al. 2015). Effectiveness of the demanding training that MI-BCIs incorporate can be improved by using protocols that are contex…”
BackgroundInfluentialBhagat, N. A., Venkatakrishnan, A., Abibullaev, B., Artz, E. J., Yozbatiran, N., Blank, A. A., French, J., Karmonik, C., Grossman, R. G., O'Malley, M. K., et al. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00122 · Cited by 174
“…proposed a neurorehabilitation regimen that augments existing robot-assisted therapy with closed-loop EEG-based BMI (Daly et al., 2008; Gomez-Rodriguez et al., 2011; Ramos-murguialday et al., 2014; Xu et al., 2014b; Ang et al., 2015) or magnetoencephalography (MEG)-based BMI (Buch et al., 2008).”
BackgroundImplementation of a Brain-Computer Interface on a Lower-Limb Exoskeleton
Wang, C., Wu, X., Wang, Z., & Ma, Y. (2018) · IEEE Access · doi:10.1109/access.2018.2853628 · Cited by 89
“In addition, there are also some similar works [17]–[19] which we do not mention too much.”
BackgroundSelf-citationNeuroengineering challenges of fusing robotics and neuroscience
Cheng, G., Ehrlich, S. K., Lebedev, M., & Nicolelis, M. A. L. (2020) · Science Robotics · doi:10.1126/scirobotics.abd1911 · Cited by 55
Wei, W., Qiu, S., Zhang, Y., Mao, J., & He, H. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac5eb7 · Cited by 24
“BCI systems can provide basic communication and control capabilities for paralyzed patients [2, 3], or promote functional recovery for patients with stroke [4, 5].”
Qin, Y., Xu, Q., Kujala, T., Wang, X., & Cong, F. (2026) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2026.109535 · Cited by 1
Metadata
- Authors
- Ang, K. K., Chua, K. S. G., Phua, K. S., Wang, C., Chin, Z. Y., Kuah, C. W. K., Low, W., & Guan, C.
- Venue
- Clinical EEG and Neuroscience
- Publisher
- SAGE Publications
- Published
- 2014-04-21
- Volume
- 46
- Issue
- 4
- Pages
- 310-320
- ISSN
- 1550-0594 (ISSN-L)
- 2169-5202
- OpenAlex
- W1971140534
- Cited by
- 539
- References
- 48
- FWCI
- 25.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.