Use of Continuous Glucose Monitoring in the Detection and Prevention of Hypoglycemia
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Intensive diabetes therapy is complicated by an increased rate of hypoglycemia and the development of hypoglycemia unawareness. This presentation focuses on the potential role of real-time continuous glucose monitoring (CGM) in preventing hypoglycemia, and in overcoming this barrier to the implementation of intensive therapy. Issues to be discussed include the differences between capillary blood and interstitial glucose levels, the impact of lag times on sensor calibration and accuracy, and the importance of patient education in minimizing the risk for hypoglycemia from uncontrolled postprandial bolusing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hypoglycemia in Type 2 Diabetes
Zammitt, N. N., & Frier, B. M. (2005) · Diabetes Care · doi:10.2337/diacare.28.12.2948 · Cited by 435
Fanelli, C. G., Epifano, L., Rambotti, A. M., Pampanelli, S., Di Vincenzo, A., Modarelli, F., Lepore, M., Annibale, B., Ciofetta, M., Bottini, P., et al. (1993) · Diabetes · doi:10.2337/diab.42.11.1683 · Cited by 398
Cited by
Fokkert, M. J., van Dijk, P. R., Edens, M. A., Abbes, S., de Jong, D., Slingerland, R. J., & Bilo, H. J. G. (2017) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2016-000320 · Cited by 209
The importance of hypoglycemia in diabetic patients
Shafiee, G., Mohajeri-Tehrani, M., Pajouhi, M., & Larijani, B. (2012) · Journal of Diabetes & Metabolic Disorders · doi:10.1186/2251-6581-11-17 · Cited by 163
“CGM may be particularly important for patients with hypoglycemia unawareness and/or patients experiencing frequent episodes of hypoglycemia [72].”
BackgroundCichosz, S. L., Johansen, M. D., & Hejlesen, O. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815611680 · Cited by 101
“However, using CGM for prediction of hypoglycemia involves accepting a certain proportion of false positive alarms.(95-98) Hypoglycemia affects the entire autonomic nervous system, including the heart, the brain, and perspiration.”
MethodCichosz, S. L., Frystyk, J., Hejlesen, O. K., Tarnow, L., & Fleischer, J. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814528838 · Cited by 88
“This comes with a trade-off partly because of the 10-minute lag time from changes in blood glucose and partly because of poor accuracy of the CGM systems in measuring glucose values within the hypoglycemic range.(36,37) The result is an increased number of false alarms or even false security.”
BackgroundBurnett, D. R., Huyett, L. M., Zisser, H. C., Doyle, F. J., & Mensh, B. D. (2014) · Diabetes · doi:10.2337/db13-1649 · Cited by 52
“Thirdly, subcutaneous kinetics have been variably reported to be moderately slow (17–25) and likely worsen with implantation time as the encapsulation develops (26,27).”
Background
Metadata
- Authors
- Wolpert, H. A.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2007-01
- Volume
- 1
- Issue
- 1
- Pages
- 146-150
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2077641110
- Cited by
- 41
- References
- 2
- Type
- conference abstract
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.