Cited by 166Intramuscular injections and effectsAdvancements in Transdermal Drug DeliveryIntravenous Infusion Technology and Safety

The DOI matches its Crossref record; 28 of the 29 references it cites were found in a registry or an index.

Does Needle Size Matter?

Open access
Gill, Harvinder S., Prausnitz, Mark R.·2007·Journal of Diabetes Science and Technology

Abstract

Hypodermic needles are in widespread use, but patients are unhappy with the pain, anxiety, and difficulty of using them. To increase patient acceptance, smaller needle diameters and lower insertion forces have been shown to reduce the frequency of painful injections. Guided by these observations, fine needles and microneedles have been developed to minimize pain and have found the greatest utility for delivery of vaccines and biopharmaceuticals such as insulin. However, pain reduction must be balanced against limitations of injection depth, volume, and formulations introduced by reduced needle dimensions. In some cases, needle-free delivery methods provide useful alternatives.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/193229680700100517

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 29 references

Research works printed but not linked: 3

  1. Kroger A, MMWR Recomm Rep, 55
  2. Schneider LW, Peck LS, Melvin JW. Penetration characteristics of hypodermic needles in skin and muscle tissue. Phase I (Appendices B-E). Final report. Highway Safety Research Institute, Ann Arbor, MI; 1978. Persistent URL http://hdl.handle.net/2027.42/614.
  3. Gupta J, Felner E, Prausnitz MR. Microneedles for minimally invasive transdermal insulin delivery: An in vivo study in human diabetic subjects. Proceedings of the 6th Annual Diabetes Technology Meeting; 2006.

Cited by

Sorted by citations

Items 101–166 of 166

Metadata

Authors
Gill, H. S., & Prausnitz, M. R.
Affiliations
Georgia Institute of Technology (US)
Corresponding author
Prausnitz, Mark R.
Venue
Journal of Diabetes Science and Technology
Published
2007-09
Volume
1
Issue
5
Pages
725-729
ISSN
1932-2968 (ISSN-L)
OpenAlex
W2148727825
Cited by
164
References
29
Citations by year
2026: 10 · 2025: 10 · 2024: 11 · 2023: 16 · 2022: 14 · 2021: 16 · 2020: 16 · 2019: 13 · 2018: 5 · 2017: 10 · 2016: 8 · 2015: 13 · 2014: 3 · 2013: 7 · 2012: 3
FWCI
0.72
Type
journal article
Language
en
Open access
Locations
  • Journal of Diabetes Science and Technology (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
Pfizer
Topics
  • Health Sciences › Medicine › Emergency Medicine › Intramuscular injections and effects
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Advancements in Transdermal Drug Delivery
  • Physical Sciences › Engineering › Biomedical Engineering › Intravenous Infusion Technology and Safety
Keywords
needle size, hypodermic needle, injection pain, microneedles, fine needle, insulin delivery, vaccine delivery, biopharmaceutical delivery, injection depth, patient acceptance

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review