CoChat

Treatment Satisfaction and Quality of Life for an Integrated Continuous Glucose Monitoring/Insulin Pump System Compared to Self-Monitoring plus an Insulin Pump

Open access
Rubin, Richard R., Peyrot, Mark · 2009 · Journal of Diabetes Science and Technology
Cited by 54

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background: Little is known about how the most advanced technology affects treatment satisfaction and health-related quality of life (HRQOL) in adults with diabetes. This study was designed to assess treatment satisfaction and HRQOL among users of an integrated real-time (RT) continuous glucose monitoring (CGM)/continuous subcutaneous insulin infusion (CSII) system compared with those using self-monitoring of blood glucose (SMBG) with CSII. Methods: Participants were 311 adult respondents to an Internet survey, 162 using RT-CGM/CSII, 149 using SMBG + CSII (median age 43 years; type 1 diabetes 94%; diabetes duration >15 years 61%; median insulin use 15 years). Respondents completed instruments assessing glucose monitoring system and insulin delivery system convenience, interference, burden, glucose control efficacy, cost satisfaction, overall satisfaction, and treatment preference, as well as quality of life (diabetes-related worries, social burden, and psychological well-being). Real-time CGM/CSII users also assessed specific elements of the RT-CGM/CSII system. Group differences were assessed using analysis of covariance controlling for respondent characteristics. Results: The RT-CGM/CSII group gave significantly better ratings than the SMBG + CSII group for their glucose monitoring system's glucose control efficacy, overall satisfaction, desire to switch, and willingness to recommend, and significantly worse ratings for interference with daily activities. The RT-CGM/CSII group gave significantly better ratings than the SMBG + CSII group for their insulin delivery system's convenience and glucose control efficacy, overall satisfaction, desire to switch, and willingness to recommend. Real-time CGM/CSII users gave positive ratings of all system features. Conclusions: Users of the integrated RT-CGM/CSII system reported more benefits of treatment, higher treatment satisfaction and quality of life, and greater preference for this system than SMBG + CSII users.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/193229680900300621

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 54

Metadata

Authors
Rubin, R. R., & Peyrot, M.
Venue
Journal of Diabetes Science and Technology
Published
2009-11
Volume
3
Issue
6
Pages
1402-1410
ISSN
1932-2968 (ISSN-L)
OpenAlex
W1970862766
Cited by
54
References
2
FWCI
2.17
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Treatment Satisfaction and Quality of Life for an Integrated Continuous Glucose Monitoring/Insulin Pump System Compared to Self-Monitoring plus an Insulin Pump. https://app.cochat.ai/papers/10.1177/193229680900300621
The paper
Rubin, R. R., & Peyrot, M. (2009). Treatment Satisfaction and Quality of Life for an Integrated Continuous Glucose Monitoring/Insulin Pump System Compared to Self-Monitoring plus an Insulin Pump. Journal of Diabetes Science and Technology. https://doi.org/10.1177/193229680900300621

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.