Second Insulin Pump Safety Meeting: Summary Report
Open accessThe DOI matches its Crossref record.
Abstract
Diabetes Technology Society facilitated a second meeting of insulin pump experts at Mills-Peninsula Health Services, San Mateo, California on November 4, 2009, at the request of the Food and Drug Administration, Center for Devices and Radiological Health, Office of Science and Engineering Laboratories. The first such meeting was held in Bethesda, Maryland, on November 12, 2008. The group of physicians, nurses, diabetes educators, and engineers from across the United States discussed safety issues in insulin pump therapy and recommended adjustments to current insulin pump design and use to enhance overall safety. The meeting discussed safety issues in the context of pump operation; software; hardware; physical structure; electrical, biological, and chemical considerations; use; and environment from engineering, medical, nursing, and pump/user perspectives. There was consensus among meeting participants that insulin pump designs have made great progress in improving the quality of life of people with diabetes, but much more remains to be done.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Insulin pump-associated adverse events in children and adolescents–a prospective study
Wheeler, B. J., Heels, K., Donaghue, K. C., Reith, D. M., & Ambler, G. R. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0388 · Cited by 64
A Hazard Analysis for a Generic Insulin Infusion Pump
Zhang, Y., Jones, P. L., & Jetley, R. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400207 · Cited by 61
Self-citationRobust Fault Detection System for Insulin Pump Therapy Using Continuous Glucose Monitoring
Herrero, P., Calm, R., Vehí, J., Armengol, J., Georgiou, P., Oliver, N., & Tomazou, C. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600518 · Cited by 52
Cope, J. U., Samuels-Reid, J. H., & Morrison, A. E. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600509 · Cited by 35
Family Perceptions of Insulin Pump Adverse Events in Children and Adolescents
Wheeler, B. J., Donaghue, K. C., Heels, K., & Ambler, G. R. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0315 · Cited by 31
Aleppo, G., DeSalvo, D. J., Lauand, F., Huyett, L. M., Chang, A., Vienneau, T., & Ly, T. T. (2023) · Diabetes Therapy · doi:10.1007/s13300-023-01366-9 · Cited by 19
“Many tubed pump users report disconnecting their pumps without suspending the flow of insulin [58, 59], which can waste insulin and result in an inflated TDD value not observed when initiating a tubeless pump for these users.”
BackgroundInsulin Pump Alarms During Adverse Events: A Qualitative Descriptive Study
Estock, J. L., Codario, R. A., Zupa, M. F., Keddem, S., & Rodriguez, K. L. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231209999 · Cited by 4
Metadata
- Authors
- Zhang, Y., Jones, P. L., & Klonoff, D. C.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2010-03
- Volume
- 4
- Issue
- 2
- Pages
- 488-493
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2041762240
- Cited by
- 16
- References
- 0
- Type
- conference abstract
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.