The Current Status of Bolus Calculator Decision-Support Software
Open accessThe DOI matches its Crossref record.
Abstract
The purpose of self-monitoring of blood glucose is to take action based on the results of the tests. The three actions that must be taken by insulin-using diabetes patients in response to blood glucose self-testing are, first, to record the blood glucose level, second, to calculate an appropriate dose of insulin, and, third, to administer the dose of insulin. A low-technology solution exists for each of these three actions. In addition, a commonly used high-technology solution exists for the first and third of these three actions (recording the blood glucose level and administering the insulin dose), but no high-technology product is currently approved by the Food and Drug Administration (FDA) for calculating an insulin dose (Figure 1). The currently unavailable high-technology approach to glucose-directed insulin dosing is approved software for calculating a bolus dose of insulin. Figure 1 Technology to apply to blood glucose data for administering an appropriate dose of insulin. In the first article to report a premeal bolus calculator was a system that was intended for use by insulin pump users.1 The bolus formula in that article incorporated five elements: (1) the carbohydrate/insulin ratio (carbo-hydrate bolus dose); (2) the insulin/carbohydrate ratio (correction bolus dose); (3) the target postprandial blood glucose; (4) the current blood glucose level; and (5) the carbohydrate content of the planned meal. The first four of these elements were known in advance and could be preprogrammed. Only the meal content would need to be entered at the time of the meal. Four factors that could affect the dose calculation, but were not accounted for, were as follows: (1) any correction bolus insulin onboard from a recently administered correction bolus insulin dose; (2) any carbohydrate bolus insulin onboard from a recently administered correction bolus insulin dose; (3) exercise either recently since the last dose of insulin or planned soon; or (4) any food onboard since the last dose of insulin. Accounting for these four factors could make for a more accurate bolus calculator to match a lifestyle, food, or physical activity choice with a correct dose.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Peters, A. L., Ahmann, A. J., Battelino, T., Evert, A., Hirsch, I. B., Murad, M. H., Winter, W. E., & Wolpert, H. (2016) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2016-2534 · Cited by 250
Schmidt, S., & Nørgaard, K. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814532906 · Cited by 170
Cappon, G., Vettoretti, M., Marturano, F., Facchinetti, A., & Sparacino, G. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818759558 · Cited by 62
Herrero, P., Pesl, P., Bondia, J., Reddy, M., Oliver, N., Georgiou, P., & Toumazou, C. (2015) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2015.02.003 · Cited by 43
Cappon, G., Marturano, F., Vettoretti, M., Facchinetti, A., & Sparacino, G. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818777524 · Cited by 18
Metadata
- Authors
- Klonof, D. C.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2012-09
- Volume
- 6
- Issue
- 5
- Pages
- 990-994
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2121605809
- Cited by
- 32
- References
- 0
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Current Status of Bolus Calculator Decision-Support Software. https://app.cochat.ai/papers/10.1177/193229681200600501
- The paper
- Klonof, D. C. (2012). The Current Status of Bolus Calculator Decision-Support Software. Journal of Diabetes Science and Technology. https://doi.org/10.1177/193229681200600501
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.