CoChat

Design of the Health Monitoring System for the Artificial Pancreas: Low Glucose Prediction Module

Open access
Harvey, Rebecca A., Dassau, Eyal, Zisser, Howard, Seborg, Dale E., Jovanovič, Lois, Doyle, Francis J. · 2012 · Journal of Diabetes Science and Technology
Cited by 52

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Background: The purpose of this study was to design and evaluate a safety system for the artificial pancreas device system (APDS). Safe operation of the APDS is a critical task, where the safety system is engaged only as needed to ensure reliable operation without positive feedback to the controller. Methods: The Health Monitoring System (HMS) was designed as a modular system to ensure the safety of the APDS and the user. It was designed using a large set of ambulatory data and evaluated in silico by inducing hypoglycemia with a missed meal [bolus for a 65 g carbohydrate (CHO) meal] and administering rescue CHOs per HMS alerting. The HMS was validated in-clinic with a real-life challenge of a subject who overdosed insulin prior to admission. Results: The HMS was evaluated for clinical use with a 15 min prediction horizon. Retrospectively, 93.5% of episodes were detected with 2.9 false alarms per day. During in silico evaluation, the HMS reduced the time spent <70 mg/dl from 15% to 3%. When the HMS was first tested in-clinic, the subject overdosed ∼3 U of insulin prior to her arrival to a closed-loop session (against protocol). The controller reduced insulin delivery, and the HMS gave four alerts that were successfully received via clinical software and text and multimedia messages. Even with insulin reduction and CHO supplements, hypoglycemia was unavoidable but manageable due to the HMS, confirming that a safety system to detect adverse events is an essential part of the APDS. Conclusions: The ability of the HMS to be an effective alert system that provides a safety layer to the APDS controller has been demonstrated in a clinical setting.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/193229681200600613

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 52

Metadata

Authors
Harvey, R. A., Dassau, E., Zisser, H., Seborg, D. E., Jovanovič, L., & Doyle, F. J.
Venue
Journal of Diabetes Science and Technology
Published
2012-11
Volume
6
Issue
6
Pages
1345-1354
ISSN
1932-2968 (ISSN-L)
OpenAlex
W1988792776
Cited by
52
References
6
FWCI
3.68
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.