CoChat

Accuracy Evaluation of Five Blood Glucose Monitoring Systems: The North American Comparator Trial

Open access
Halldorsdottir, Solveig, Warchal-Windham, Mary Ellen, Wallace, Jane F., Pardo, Scott, Parkes, Joan Lee, Simmons, David A. · 2013 · Journal of Diabetes Science and Technology
Cited by 31

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background: This study evaluated differences in accuracy between the CONTOUR® NEXT EZ (EZ) blood glucose monitoring system (BGMS) and four other BGMSs [ACCU-CHEK® Aviva (ACAP), FreeStyle Freedom Lite® (FFL), ONE TOUCH® Ultra®2 (OTU2), and TRUEtrack® (TT)]. Methods: Up to three capillary blood samples ( N = 393) were collected from 146 subjects with and without diabetes. One sample per subject was tested with fresh (natural) blood; the other samples were glycolyzed to lower blood glucose to <70 mg/dl. Meter results were compared with results from plasma from the same sample tested on a Yellow Springs Instruments (YSI) 2300 STAT Plus™ glucose analyzer. Blood glucose monitoring system accuracy was compared using mean absolute relative difference (MARD; from laboratory reference method results) and other analyses. Separate analyses on fresh (natural) samples only were conducted to determine potential effects of glycolysis on MARD values of systems utilizing glucose-oxidase-based test strip chemistry. Results: Across the tested glucose range, the EZ had the lowest MARD of 4.7%; the ACAP, FFL, OTU2, and TT had MARD values of 6.3%, 18.3%, 23.4%, and 26.2%, respectively. For samples with glucose concentrations <70 mg/dl, the EZ had the lowest MARD (0.65%), compared with the ACAP (2.5%), FFL (18.3%), OTU2 (22.4%), and TT (33.2%) systems. Conclusions: The EZ had the lowest MARD across the tested glucose ranges when compared with four other BGMSs when all samples were analyzed as well as when natural samples only were analyzed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/193229681300700520

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 31

Metadata

Authors
Halldorsdottir, S., Warchal-Windham, M. E., Wallace, J. F., Pardo, S., Parkes, J. L., & Simmons, D. A.
Venue
Journal of Diabetes Science and Technology
Published
2013-09
Volume
7
Issue
5
Pages
1294-1304
ISSN
1932-2968 (ISSN-L)
OpenAlex
W2138128534
Cited by
31
References
3
FWCI
4.48
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy Evaluation of Five Blood Glucose Monitoring Systems: The North American Comparator Trial. https://app.cochat.ai/papers/10.1177/193229681300700520
The paper
Halldorsdottir, S., Warchal-Windham, M. E., Wallace, J. F., Pardo, S., Parkes, J. L., & Simmons, D. A. (2013). Accuracy Evaluation of Five Blood Glucose Monitoring Systems: The North American Comparator Trial. Journal of Diabetes Science and Technology. https://doi.org/10.1177/193229681300700520

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.