The Effect of Continuous Glucose Monitoring in Preventing Inpatient Hypoglycemia in General Wards: The Glucose Telemetry System
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Background: Few studies have examined the use of continuous glucose monitoring (CGM) devices in the general wards. The aim of this pilot study was to examine whether CGM readings can be successfully transmitted from the bedside to a central monitoring device in the nursing station, and whether a glucose telemetry system can prevent hypoglycemic events. Methods: We present pilot data on 5 consecutive insulin treated general medicine patients with type 2 diabetes (T2DM) whose glucose values were observed with CGM (DEXCOM) and the results were transmitted to a central nursing station monitoring system using DEXCOM Follow and Share 2 software. CGM alarms were set-up at glucose <85 mg/dl. Results: Duration of CGM observation was 4.0 ± 1.6 days (mean ± SD). During CGM, the overall time spent within blood glucose (BG) target of 70-179 mg/dl was 64.68 ± 15% (mean ± SD), on hypoglycemia (<70 mg/dl) was 0.30% ± 0.39, and time spent on hyperglycemia (≥180 mg/dl) was 35.02% ± 15.5. Two patients had 3 actions of prevention of potential hypoglycemia (CGM BG <70 mg/dl for >20 minutes) captured by alarm. No patients had CGM glucose value <54 mg/dl. Conclusions: This pilot study indicates that the use of CGM values in hospitalized patients can be successfully transmitted to a monitoring device in the nursing station, improving patient surveillance in insulin treated patients with diabetes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hyperglycemia: an independent marker of in-hospital mortality in patients with undiagnosed diabetes
Umpierrez, G. E., Isaacs, S. D., Bazargan, N., You, X., Thaler, L. M., & Kitabchi, A. E. (2002) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.87.3.8341 · Cited by 2,195 · cited 1×
“non–intensive care unit (non-ICU) setting have history of diabetes mellitus (DM).(1) Inpatient hyperglycemia is associ-”
BackgroundSelf-citationUmpierrez, G. E., Hellman, R., Korytkowski, M. T., Kosiborod, M., Maynard, G. A., Montori, V. M., Seley, J. J., & Van den Berghe, G. (2012) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2011-2098 · Cited by 1,126
Self-citationUmpierrez, G. E., Smiley, D., Jacobs, S., Peng, L., Temponi, A., Mulligan, P., Umpierrez, D., Newton, C., Olson, D., & Rizzo, M. (2011) · Diabetes Care · doi:10.2337/dc10-1407 · Cited by 720
Self-citationUmpierrez, G. E., Smiley, D., Zisman, A., Prieto, L. M., Palacio, A., Ceron, M., Puig, A., & Mejia, R. (2007) · Diabetes Care · doi:10.2337/dc07-0295 · Cited by 671
Self-citationInternational Hypoglycaemia Study Group (2017) · Diabetes Care · doi:10.2337/dc16-2215 · Cited by 608
Hypoglycemia and clinical outcomes in patients with diabetes hospitalized in the general ward
Turchin, A., Matheny, M. E., Shubina, M., Scanlon, J. V., Greenwood, B., & Pendergrass, M. L. (2009) · Diabetes Care · doi:10.2337/dc08-2127 · Cited by 453 · cited 1×
“pital have been associated with adverse outcomes such as increased mortality and prolonged length of stay.(15) Medical centers have implemented protocols designed to prevent and treat inpatient hypoglycemia and its potentially serious complications.”
BackgroundChow, E., Bernjak, A., Williams, S., Fawdry, R. A., Hibbert, S., Freeman, J., Sheridan, P. J., & Heller, S. R. (2014) · Diabetes · doi:10.2337/db13-0468 · Cited by 403
Continuous glucose monitoring: an Endocrine Society Clinical Practice Guideline
Klonoff, D. C., Buckingham, B., Christiansen, J. S., Montori, V. M., Tamborlane, W. V., Vigersky, R. A., & Wolpert, H. (2011) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-2756 · Cited by 211
Hypoglycemia-associated mortality is not drug-associated but linked to comorbidities
Boucai, L., Southern, W. N., & Zonszein, J. (2011) · The American Journal of Medicine · doi:10.1016/j.amjmed.2011.07.011 · Cited by 175
Stahn, A., Pistrosch, F., Ganz, X., Teige, M., Koehler, C., Bornstein, S., & Hanefeld, M. (2014) · Diabetes Care · doi:10.2337/dc13-0600 · Cited by 173
Cited by
Blonde, L., Umpierrez, G. E., Reddy, S. S., McGill, J. B., Berga, S. L., Bush, M., Chandrasekaran, S., DeFronzo, R. A., Einhorn, D., Galindo, R. J., et al. (2022) · Endocrine Practice · doi:10.1016/j.eprac.2022.08.002 · Cited by 507
Self-citationDiabetes Technology Update: Use of Insulin Pumps and Continuous Glucose Monitoring in the Hospital
Umpierrez, G. E., & Klonoff, D. C. (2018) · Diabetes Care · doi:10.2337/dci18-0002 · Cited by 251
“5-fold higher (94) compared with capillary POC glucose testing in general medicine patients with T2D treated with a basal-bolus insulin regimen for $3 days.”
BackgroundInfluentialSelf-citationContinuous glucose monitors and automated insulin dosing systems in the hospital consensus guideline
Galindo, R. J., Umpierrez, G. E., Rushakoff, R. J., Basu, A., Lohnes, S., Nichols, J. H., Spanakis, E. K., Espinoza, J., Palermo, N. E., Awadjie, D. G., et al. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820954163 · Cited by 170
Self-citationGalindo, R. J., Aleppo, G., Klonoff, D. C., Spanakis, E. K., Agarwal, S., Vellanki, P., Olson, D. E., Umpierrez, G. E., Davis, G. M., & Pasquel, F. J. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820932903 · Cited by 155
“Consider that transmission of patient CGM data to both the individual provider smartphone and a GTS may help prevent gaps in CGM data review or alert notifications in the setting of high patient care demands.”
Self-citationSingh, L. G., Satyarengga, M., Marcano, I., Scott, W. H., Pinault, L. F., Feng, Z., Sorkin, J. D., Umpierrez, G. E., & Spanakis, E. K. (2020) · Diabetes Care · doi:10.2337/dc20-0840 · Cited by 154
Self-citationSpanakis, E. K., Urrutia, A., Galindo, R. J., Vellanki, P., Migdal, A. L., Davis, G., Fayfman, M., Idrees, T., Pasquel, F. J., Coronado, W. Z., et al. (2022) · Diabetes Care · doi:10.2337/dc22-0716 · Cited by 153
Self-citationType 2 Diabetes and the Use of Real-Time Continuous Glucose Monitoring
Jackson, M. A., Ahmann, A., & Shah, V. N. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0007 · Cited by 106
Davis, G. M., Faulds, E., Walker, T., Vigliotti, D., Rabinovich, M., Hester, J., Peng, L., McLean, B., Hannon, P., Poindexter, N., et al. (2021) · Diabetes Care · doi:10.2337/dc20-2085 · Cited by 94
“glucose telemetry (tablet) at the nursing station (15).”
BackgroundSelf-citationDiabetes technology in the inpatient setting for management of hyperglycemia
Davis, G. M., Galindo, R. J., Migdal, A. L., & Umpierrez, G. E. (2020) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2019.11.002 · Cited by 62
Self-citationAccuracy of continuous glucose monitors for inpatient diabetes management
Wright, J. J., Williams, A. J., Friedman, S. B., Weaver, R. G., Williams, J. M., Hodge, E., Fowler, M., & Bao, S. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221076562 · Cited by 49
“1254 Journal of Diabetes Science and Technology 17(5)”
BackgroundBaker, M., Musselman, M. E., Rogers, R., & Hellman, R. (2022) · American Journal of Health-System Pharmacy · doi:10.1093/ajhp/zxab456 · Cited by 27
“Sensor location and condition of the skin around the insertion site was documented in the EMR An rtCGM telemetry system for remote patient monitoring in a non-ICU setting has been described previously by Spanakis et al.(22) Similarly, the rtCGM telemetry system in our project consisted of a body-worn sensor/transmitte…”
MethodHirsch, I. B., Draznin, B., Buse, J. B., Raghinaru, D., Spanbauer, C., Umpierrez, G. E., Ullal, J., Jones, M. S., Low Wang, C. C., Spanakis, E. K., et al. (2025) · Diabetes Care · doi:10.2337/dc24-1779 · Cited by 26
Self-citation
Metadata
- Authors
- Spanakis, E. K., Levitt, D. L., Siddiqui, T., Singh, L. G., Pinault, L., Sorkin, J., Umpierrez, G. E., & Fink, J. C.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2017-12-13
- Volume
- 12
- Issue
- 1
- Pages
- 20-25
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2773772558
- Cited by
- 66
- References
- 11
- FWCI
- 4.45
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.