Further Evidence of Severe Allergic Contact Dermatitis From Isobornyl Acrylate While Using a Continuous Glucose Monitoring System
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
In the past decade, new diabetes technologies, including continuous glucose monitoring (CGM) systems, support patients with diabetes in their daily struggle with achieving a good glucose control. However, shortly after the first CGM systems appeared on the market, also the first concerns about adverse skin reactions were raised. Most patients claimed to suffer from (sometimes severe) skin irritation, or even allergy, which they related to the (acrylate-based) adhesive part of the device. For a long time the actual substance that caused these skin reactions with, for example, the Flash Glucose Monitoring system (iscCGM; Freestyle® Libre) could not be identified; however, recently Belgian and Swedish dermatologists reported that the majority of their patients that have developed a contact-allergic while using iscCGM react sensitively to a specific acrylate, that is, isobornyl acrylate (IBOA). Subsequently they showed by means of gas chromatography-mass spectrometry that this substance is present in the case of the glucose sensor attached by an adhesive to the skin. We report three additional cases from Germany, including a 10-year-old boy, suffering from severe allergic contact dermatitis to IBOA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In some cases, this has been linked to the presence of isobornyl acrylate, a skin sensitizer that can cause an additional spreading allergic reaction (119-121).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [119]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Herman, A., Aerts, O., Baeck, M., Bruze, M., De Block, C., Goossens, A., Hamnerius, N., Huygens, S., Maiter, D., Tennstedt, D., et al. (2017) · Contact Dermatitis · doi:10.1111/cod.12866 · Cited by 192
Self-citationAdhesives Used for Diabetes Medical Devices: A Neglected Risk With Serious Consequences?
Heinemann, L., & Kamann, S. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816662949 · Cited by 74 · cited 1×
“Until recently there were only a few reports on skin allergy caused by components of devices used for diabetes therapy.(2) In 1995, two young women, who showed a contact-allergic skin reaction to two different insulin pumps were described and the authors revealed that one of the culprit allergens was IBOA.”
Self-citationSchwensen, J. F. B., Friis, U. F., Zachariae, C. O. C., & Johansen, J. D. (2016) · Contact Dermatitis · doi:10.1111/cod.12503 · Cited by 62 · cited 1×
“A case of sensitization to cyanoacrylate, caused by exposure to a CGM system in another child with diabetes, was recently described.(4) In this particular case cyanoacrylate was shown to be a component of the thin layer glue that binds the sensor to the adhesive.”
Contact allergy to components of glue in insulin pump infusion sets
Busschots, A. M., Meuleman, V., Poesen, N., & Dooms‐Goossens, A. (1995) · Contact Dermatitis · doi:10.1111/j.1600-0536.1995.tb00554.x · Cited by 61
Two decades of occupational (meth)acrylate patch test results and focus on isobornyl acrylate
Christoffers, W. A., Coenraads, P., & Schuttelaar, M. A. (2013) · Contact Dermatitis · doi:10.1111/cod.12023 · Cited by 46 · cited 1×
“In a recent study Christoffers et al published an analysis of two decades of occupational patch testing with acrylates in 151 patients.(6) The authors also described one case of occupational ACD to IBOA caused by uncured UV ink and acrylate coating.”
Isobornyl acrylate: an impurity in alkyl glucosides
Foti, C., Romita, P., Rigano, L., Zimerson, E., Sicilia, M., Ballini, A., Ghizzoni, O., Antelmi, A., Angelini, G., Bonamonte, D., et al. (2015) · Cutaneous and Ocular Toxicology · doi:10.3109/15569527.2015.1055495 · Cited by 45 · cited 1×
“IBOA can also be easily released into materials flowing over surfaces made from it.(5) After recontacting the adhesive manufacturer itself, they once again confirmed that IBOA is not contained in the adhesive part, nor in the layer glue between the adhesive and the sensor.”
Cited by
7. Diabetes Technology: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s007 · Cited by 358
7. Diabetes Technology: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s007 · Cited by 348
7. Diabetes Technology: Standards of Care in Diabetes — 2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s007 · Cited by 301
7. Diabetes Technology: Standards of Care in Diabetes—2024
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Hilliard, M. E., Johnson, E. L., Khunti, K., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s007 · Cited by 281
7. Diabetes Technology: Standards of Medical Care in Diabetes—2020
American Diabetes Association (2020) · Diabetes Care · doi:10.2337/dc20-s007 · Cited by 250
Metadata
- Authors
- Kamann, S., Aerts, O., & Heinemann, L.
- Affiliations
- Pöcking, Germany
- University of Antwerp (BE)
- Science & Co, Düsseldorf, Deutschland, Germany
- Corresponding author
- Kamann, Stefanie
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2018-03-15
- Volume
- 12
- Issue
- 3
- Pages
- 630-633
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC6154227
- OpenAlex
- W2793234916
- Cited by
- 85
- References
- 6
- Citations by year
- 2026: 2 · 2025: 5 · 2024: 7 · 2023: 4 · 2022: 11 · 2021: 13 · 2020: 19 · 2019: 17 · 2018: 6
- FWCI
- 14.88
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Dermatology › Contact Dermatitis and Allergies
- Health Sciences › Medicine › Pharmacology (medical) › Drug-Induced Adverse Reactions
- Health Sciences › Medicine › Dermatology › Skin Diseases and Diabetes
- Keywords
- allergic contact dermatitis, isobornyl acrylate, continuous glucose monitoring, skin irritation, diabetes technology, pediatric patients
- MeSH terms
- Acrylates, Adhesives, Camphanes, Child, Diabetes Mellitus, Type 1, Humans, Male, Blood Glucose Self-Monitoring, Dermatitis, Allergic Contact
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.