CoChat

Evaluation of Linearity and Interference Effect on SMBG and POCT Devices, Showing Drastic High Values, Low Values, or Error Messages

Open access
Sai, Shizuki, Urata, Mitsunori, Ogawa, Iwao · 2019 · Journal of Diabetes Science and Technology

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Background: When a patient with diabetes measures blood glucose levels using a simple blood glucose meter, an error message or abnormal value may be displayed because of interfering substances, potentially leading to unnecessary medical treatment. Methods: Here, we tested 10 self-monitoring of blood glucose (SMBG) and point-of-care testing (POCT) devices to investigate under what conditions they fail to measure blood glucose levels or display abnormal values instead. We also evaluated the influence and linearity of several well-known interfering substances and hematocrit (Ht). Each adjusted sample was measured by each device twice and the values compared with the reference values. Results: Linearity was favorable in all but one model. The impact of the interfering substances and Ht has been confirmed in many SMBG and POCT devices. In particular, some models showed significant pseudo-high or -low levels for samples that contained ascorbic acid, which is used widely in infusion solutions. Three devices showed error messages to avoid presenting a false value. Conclusions: Since pseudo-high levels may result in the excessive administration of insulin and lead to adverse events, this report serves as a critical reminder of the importance of device choice for specific indications. Three new devices have safety functions that prevent the showing of false values.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/1932296818821664

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Research works printed but not linked: 14

  1. American Diabetes Association, 2015, Diabetes Care, 38
  2. Kawashima H., 2016, J Med Pharm Sci, 73, 211
  3. Usami M, 2013, J Clin Lab Instr Reag, 36, 207
  4. Nagatomo R, 2013, Practice, 30, 103
  5. Tsuchida K, 2017, Jap J Med Tech, 66, 110
  6. Fujisaki N, 2013, J Jap Diabet Soc, 56, 666
  7. Miura F, 2009, J Jap Diabet Soc, 52, 865
  8. Yamazaki, 2009, J Clin Lab Instr Reag, 32, 707
  9. David B., 2013, POCT12-A3 Point-of-Care Blood Glucose Testing in Acute and Chronic Care Facilities; Approved Guideline
  10. Mitsui T, 2013, J New Remed Clin, 62, 2194
  11. Yoshikawa Y, 2006, J Clin Lab Instr Reag, 29, 573
  12. Koide K, 2017, Diabetes, 66, A183
  13. Miura F, 2009, Diabetes Japan, 52, 865
  14. Sano S, 2005, J Clin Lab Instr Reag, 28, 349

Cited by

See all 21

Metadata

Authors
Sai, S., Urata, M., & Ogawa, I.
Affiliations
PL Hospital (JP)
Corresponding author
Sai, Shizuki
Venue
Journal of Diabetes Science and Technology
Published
2019-01-19
Volume
13
Issue
4
Pages
734-743
ISSN
1932-2968 (ISSN-L)
OpenAlex
W2910826564
Cited by
20
References
7
Citations by year
2026: 2 · 2025: 3 · 2024: 5 · 2023: 4 · 2022: 1 · 2021: 3 · 2020: 1 · 2019: 1
FWCI
1.03
Type
journal article
Language
en
Open access
Licence
journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
Locations
  • Journal of Diabetes Science and Technology (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Patient Safety and Medication Errors
Keywords
self-monitoring of blood glucose, point-of-care testing, blood glucose meters, measurement linearity, interfering substances, vitamin C, hematocrit, error messages, diabetes mellitus
MeSH terms
Blood Glucose, Hematocrit, Humans, Blood Glucose Self-Monitoring, Point-of-Care Systems

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of Linearity and Interference Effect on SMBG and POCT Devices, Showing Drastic High Values, Low Values, or Error Messages. https://app.cochat.ai/papers/10.1177/1932296818821664
The paper
Sai, S., Urata, M., & Ogawa, I. (2019). Evaluation of Linearity and Interference Effect on SMBG and POCT Devices, Showing Drastic High Values, Low Values, or Error Messages. Journal of Diabetes Science and Technology. https://doi.org/10.1177/1932296818821664

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.