Wearable Performance Devices in Sports Medicine
Open accessThe DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Abstract
Context: Wearable performance devices and sensors are becoming more readily available to the general population and athletic teams. Advances in technology have allowed individual endurance athletes, sports teams, and physicians to monitor functional movements, workloads, and biometric markers to maximize performance and minimize injury. Movement sensors include pedometers, accelerometers/gyroscopes, and global positioning satellite (GPS) devices. Physiologic sensors include heart rate monitors, sleep monitors, temperature sensors, and integrated sensors. The purpose of this review is to familiarize health care professionals and team physicians with the various available types of wearable sensors, discuss their current utilization, and present future applications in sports medicine. Evidence Acquisition: Data were obtained from peer-reviewed literature through a search of the PubMed database. Included studies searched development, outcomes, and validation of wearable performance devices such as GPS, accelerometers, and physiologic monitors in sports. Study Design: Clinical review. Level of Evidence: Level 4. Results: Wearable sensors provide a method of monitoring real-time physiologic and movement parameters during training and competitive sports. These parameters can be used to detect position-specific patterns in movement, design more efficient sports-specific training programs for performance optimization, and screen for potential causes of injury. More recent advances in movement sensors have improved accuracy in detecting high-acceleration movements during competitive sports. Conclusion: Wearable devices are valuable instruments for the improvement of sports performance. Evidence for use of these devices in professional sports is still limited. Future developments are needed to establish training protocols using data from wearable devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
‘Small Changes' to Diet and Physical Activity Behaviors for Weight Management
Hills, A. P., Byrne, N. M., Lindstrom, R., & Hill, J. O. (2013) · Obesity Facts · doi:10.1159/000345030 · Cited by 9,493
Physical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638 · cited 1×
“These applications are diverse and range from ambulatory monitoring in the elderly population for falls, development of exercise programs to combat childhood obesity, and monitoring of military personnel on the battlefield.(3,21,22,26,35,46,55) Athletes present a growing niche for the use of wearable sensor technology.”
Background(1992) · Applied Ergonomics · doi:10.1016/0003-6870(92)90338-v · Cited by 7,112
Physical activity and reduced occurrence of non–insulin-dependent diabetes mellitus
Helmrich, S. P., Ragland, D. R., Leung, R. W., & Paffenbarger, R. S. (1991) · New England Journal of Medicine · doi:10.1056/nejm199107183250302 · Cited by 1,634 · cited 1×
“These applications are diverse and range from ambulatory monitoring in the elderly population for falls, development of exercise programs to combat childhood obesity, and monitoring of military personnel on the battlefield.(3,21,22,26,35,46,55) Athletes present a growing niche for the use of wearable sensor technology.”
BackgroundNon-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247 · cited 1×
“These applications are diverse and range from ambulatory monitoring in the elderly population for falls, development of exercise programs to combat childhood obesity, and monitoring of military personnel on the battlefield.(3,21,22,26,35,46,55) Athletes present a growing niche for the use of wearable sensor technology.”
BackgroundHu, F. B., Sigal, R. J., Rich-Edwards, J. W., Colditz, G. A., Solomon, C. G., Willett, W. C., Speizer, F. E., & Manson, J. E. (1999) · JAMA · doi:10.1001/jama.282.15.1433 · Cited by 914 · cited 1×
“These applications are diverse and range from ambulatory monitoring in the elderly population for falls, development of exercise programs to combat childhood obesity, and monitoring of military personnel on the battlefield.(3,21,22,26,35,46,55) Athletes present a growing niche for the use of wearable sensor technology.”
BackgroundIntroduction to GPS: The Global Positioning System
El‐Rabbany, A. (2002) · Cited by 909
Validity of 10 Electronic Pedometers for Measuring Steps, Distance, and Energy Cost
CROUTER, S. E., SCHNEIDER, P. L., KARABULUT, M., & BASSETT, D. R. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000078932.61440.a2 · Cited by 899
Rampinini, E., Impellizzeri, F. M., Castagna, C., Coutts, A. J., & Wisløff, U. (2009) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2007.10.002 · Cited by 812
Varley, M. C., Fairweather, I. H., & Aughey, R. J. (2012) · Journal of Sports Sciences · doi:10.1080/02640414.2011.627941 · Cited by 646
Cited by
Skin-Interfaced Wearable Sweat Sensors for Precision Medicine
Min, J., Tu, J., Xu, C., Lukas, H., Shin, S., Yang, Y., Solomon, S. A., Mukasa, D., & Gao, W. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00823 · Cited by 712
Camomilla, V., Bergamini, E., Fantozzi, S., & Vannozzi, G. (2018) · Sensors · doi:10.3390/s18030873 · Cited by 591
Wearable sensors for monitoring the internal and external workload of the athlete
Seshadri, D. R., Li, R. T., Voos, J. E., Rowbottom, J. R., Alfes, C. M., Zorman, C. A., & Drummond, C. K. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0149-2 · Cited by 330
Self-citationReview on Wearable Technology in Sports: Concepts, Challenges and Opportunities
Seçkin, A. Ç., Ateş, B., & Seçkin, M. (2023) · Applied Sciences · doi:10.3390/app131810399 · Cited by 279
Sensors and Functionalities of Non-Invasive Wrist-Wearable Devices: A Review
Kamišalić, A., Fister, I., Turkanović, M., & Karakatič, S. (2018) · Sensors · doi:10.3390/s18061714 · Cited by 272
Wearable Biofuel Cells: A Review
Bandodkar, A. J., & Wang, J. (2016) · Electroanalysis · doi:10.1002/elan.201600019 · Cited by 193
Wei, K., Zhang, L., Guo, Y., & Jiang, X. (2020) · IEEE Access · doi:10.1109/access.2020.2971654 · Cited by 107
Varma, N., Cygankiewicz, I., Turakhia, M. P., Heidbuchel, H., Hu, Y.-F., Chen, L. Y., Couderc, J.-P., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.120.009204 · Cited by 74
Jaén-Carrillo, D., Roche-Seruendo, L. E., Cartón-Llorente, A., & García-Pinillos, F. (2022) · Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology · doi:10.1177/17543371211015764 · Cited by 6
Metadata
- Authors
- Li, R. T., Kling, S. R., Salata, M. J., Cupp, S. A., Sheehan, J., & Voos, J. E.
- Venue
- Sports Health: A Multidisciplinary Approach
- Publisher
- SAGE Publications
- Published
- 2015-11-11
- Volume
- 8
- Issue
- 1
- Pages
- 74-78
- ISSN
- 1941-0921 (ISSN-L)
- 1941-7381
- OpenAlex
- W2221465426
- Cited by
- 348
- References
- 50
- FWCI
- 11.08
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.