CoChat

Agreement between muscle oxygen saturation from two commercially available systems in endurance running: Moxy Monitor versus Humon Hex

Open access
Jaén-Carrillo, Diego, Roche-Seruendo, Luis E, Cartón-Llorente, Antonio, García-Pinillos, Felipe · 2022 · Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

Abstract

Analysis of changes in muscle oxygen saturation (SmO2) in sport settings has become common due to its precise, continuous and non-invasive ability to provide measurements of a particular muscle using near-infrared spectroscopy (NIRS). Therefore, this study aims to determine level of agreement between two affordable NIRS-based oximeter wearable systems for measuring SmO2 level in the vastus lateralis in endurance runners. Seventeen trained endurance male runners (age: 34.2 ± 8.1 years; body mass: 70.5 ± 6.1 kg; height: 1.75 ± 0.04 m; BMI: 23 ± 1.7) completed a submaximal 60-min run-to-exhaustion treadmill running protocol trying to cover the longest possible distance. The SmO2 rates of the vastus lateralis were co-registered and continually obtained from two separate NIRS-based oximeter wearable systems over the running trial. The between-system means comparison reveals no significant differences in SmO2 at any point of the running protocol ( p > 0.217) with trivial-to-small ES (ES 0.624). Additionally, substantial and almost perfect ICCs were obtained (ICC > 0.729). Bland-Altman plots exposed homoscedasticity ( r2 < 0.1) for all the periods analysed during the running protocol, with mean differences lower than 3.2% over the time trial. The results found here show the level of agreement between two economical NIRS-based oximeter wearable systems. Notwithstanding their level of agreement, their interchangeable use is not recommended due to the variation shown for SmO2 levels.

Overview

Integrity signals

Registry

Crossref · 10.1177/17543371211015764

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 28 references

Cited by

See all 13

Metadata

Authors
Jaén-Carrillo, D., Roche-Seruendo, L. E., Cartón-Llorente, A., & García-Pinillos, F.
Affiliations
  • Universidad San Jorge, Zaragoza, Spain
  • Universidad San Jorge (ES)
  • Department of Physical Education and Sport, University of Granada, Granada, Spain
Corresponding author
Cartón-Llorente, Antonio
Venue
Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology
Published
2021-05-05
Volume
236
Issue
3
Pages
231-237
ISSN
  • 1754-3371 (ISSN-L)
  • 1754-338X
OpenAlex
W3163201870
Cited by
6
References
28
Citations by year
2026: 1 · 2025: 3 · 2023: 1 · 2022: 1
FWCI
0.56
Type
journal article
Language
en
Open access
Licence
  • cc-by-nc-nd
  • journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
Locations
  • Proceedings of the Institution of Mechanical Engineers Part P Journal of Sports Engineering and Technology (publishedVersion)
  • Omeka S (Universidad de La Frontera) (submittedVersion, cc-by-nc-nd)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
Keywords
muscle oxygen saturation, near-infrared spectroscopy, endurance running, vastus lateralis, device interchangeability

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Agreement between muscle oxygen saturation from two commercially available systems in endurance running: Moxy Monitor versus Humon Hex. https://app.cochat.ai/papers/10.1177/17543371211015764
The paper
Jaén-Carrillo, D., Roche-Seruendo, L. E., Cartón-Llorente, A., & García-Pinillos, F. (2022). Agreement between muscle oxygen saturation from two commercially available systems in endurance running: Moxy Monitor versus Humon Hex. Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology. https://doi.org/10.1177/17543371211015764

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.