Increasing the medium-term clinical benefits of hospital-based cardiac rehabilitation by physical activity telemonitoring in coronary artery disease patients
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The purpose of this study was to evaluate the effect of a physical activity telemonitoring program on daily physical activity level, oxygen uptake capacity (VO(2peak)), and cardiovascular risk profile in coronary artery disease (CAD) patients who completed phase II cardiac rehabilitation (CR). METHODS: Eighty CAD patients who completed phase II CR were randomly assigned to an additional telemonitoring intervention or standard CR. The patients in the intervention group (n = 40) wore a motion sensor continuously for 18 weeks. Each week these patients received a step count goal, with the aim to gradually increase the patients' physical activity level. In the control group (n = 40), the patients wore an unreadable motion sensor for seven days for measurement purposes only (at start of follow-up, and after six and 18 weeks). At start of follow-up and after 18 weeks blood lipid profile, glycemic control, waist circumference and body mass index was assessed. VO(2peak) was assessed at start of follow-up, and after six and 18 weeks. Re-hospitalisation rate was followed during this timeframe. RESULTS: In the intervention group, VO(2peak) increased significantly during follow-up (P = 0.001), in the control group it did not (P = 0.273). A significant correlation was found between daily aerobic step count and improvement in VO(2peak) (P = 0.030, r = 0.47). Kaplan-Meier curve analysis showed a trend towards fewer re-hospitalisations for patients in the telemonitoring group (P = 0.09). CONCLUSIONS: The study showed that, to maintain exercise tolerance and lower re-hospitalisation rate after hospital-based CR in CAD patients, a physical activity telemonitoring program might be an effective intervention.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fletcher, G. F., Balady, G. J., Amsterdam, E. A., Chaitman, B., Eckel, R., Fleg, J., Froelicher, V. F., Leon, A. S., Piña, I. L., Rodney, R., et al. (2001) · Circulation · doi:10.1161/hc3901.095960 · Cited by 1,923
Lawler, P. R., Filion, K. B., & Eisenberg, M. J. (2011) · American Heart Journal · doi:10.1016/j.ahj.2011.07.017 · Cited by 701 · cited 1×
“Moreover, meta-analyses indicate that CR significantly lowers cardiac mortality, all-cause mortality and improves cardiovascular risk factors, including blood pressure, body weight and lipid profile.(3) Unfortunately, despite the clinical effectiveness of hospital-based CR, long-term clinical effectiveness of”
Giannuzzi, P. (2008) · Archives of Internal Medicine · doi:10.1001/archinte.168.20.2194 · Cited by 411
Piotrowicz, E., Baranowski, R., Bilinska, M., Stepnowska, M., Piotrowska, M., Wójcik, A., Korewicki, J., Chojnowska, L., Malek, L. A., Klopotowski, M., et al. (2010) · European Journal of Heart Failure · doi:10.1093/eurjhf/hfp181 · Cited by 231
Clinical Trial of an Internet-based Case Management System for Secondary Prevention of Heart Disease
Southard, B. H., Southard, D. R., & Nuckolls, J. (2003) · Journal of Cardiopulmonary Rehabilitation · doi:10.1097/00008483-200309000-00003 · Cited by 216
Utilization of the internet to deliver cardiac rehabilitation at a distance: A pilot study
Zutz, A., Ignaszewski, A., Bates, J., & Lear, S. A. (2007) · Telemedicine and e-Health · doi:10.1089/tmj.2006.0051 · Cited by 115
Cited by
Widmer, R. J., Collins, N. M., Collins, C. S., West, C. P., Lerman, L. O., & Lerman, A. (2015) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2014.12.026 · Cited by 416
Participation and adherence to cardiac rehabilitation programs. A systematic review
Ruano-Ravina, A., Pena-Gil, C., Abu-Assi, E., Raposeiras, S., van 't Hof, A., Meindersma, E., Bossano Prescott, E. I., & González-Juanatey, J. R. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2016.08.120 · Cited by 413
Telehealth exercise-based cardiac rehabilitation: a systematic review and meta-analysis
Rawstorn, J. C., Gant, N., Direito, A., Beckmann, C., & Maddison, R. (2016) · Heart · doi:10.1136/heartjnl-2015-308966 · Cited by 370
Wearable Devices in Cardiovascular Medicine
Hughes, A., Shandhi, M. M. H., Master, H., Dunn, J., & Brittain, E. (2023) · Circulation Research · doi:10.1161/circresaha.122.322389 · Cited by 291
Frederix, I., Hansen, D., Coninx, K., Vandervoort, P., Vandijck, D., Hens, N., Van Craenenbroeck, E., Van Driessche, N., & Dendale, P. (2015) · Journal of Medical Internet Research · doi:10.2196/jmir.4799 · Cited by 185
“A priori sample size calculation yielded 140 necessary patients to detect a 20% effect size of the primary outcome measure (VO 2 peak) [14] between groups (intervention group vs control group) with a statistical power of 95% at a 2-sided type I error level of .05 and a dropout rate of 30%.”
Digital Health Interventions for Cardiac Rehabilitation: Systematic Literature Review
Wongvibulsin, S., Habeos, E. E., Huynh, P. P., Xun, H., Shan, R., Porosnicu Rodriguez, K. A., Wang, J., Gandapur, Y. K., Osuji, N., Shah, L. M., et al. (2021) · Journal of Medical Internet Research · doi:10.2196/18773 · Cited by 178
“In total, 2 of the 8 studies reported an increase in high-density lipoprotein in the intervention group [31,37], 2 of the 8 reported decreased low-density lipoprotein and total cholesterol [18,32], and 2 of the 8 studies reported a decrease in triglycerides [29,30].”
InfluentialAkinosun, A. S., Polson, R., Diaz - Skeete, Y., De Kock, J. H., Carragher, L., Leslie, S., Grindle, M., & Gorely, T. (2021) · JMIR mHealth and uHealth · doi:10.2196/21061 · Cited by 159
“Unclear Low Low Low High Low Low Low Low Frederix et al, 2015 [21]”
BackgroundEvaluating the Impact of Physical Activity Apps and Wearables: Interdisciplinary Review
McCallum, C., Rooksby, J., & Gray, C. M. (2018) · JMIR mhealth and uhealth · doi:10.2196/mhealth.9054 · Cited by 126
“Overall, from the 1829 abstracts and 858 full texts read, a total of 128 articles were included in the review [39-166], representing 111 unique studies.”
BackgroundCruz-Cobo, C., Bernal-Jiménez, M. Á., Vázquez-García, R., & Santi-Cano, M. J. (2022) · JMIR mHealth and uHealth · doi:10.2196/39593 · Cited by 74
“The secondary prevention of CAD is considered essential at present [5], as it has contributed significantly to the decrease in morbidity and mortality by facilitating the adoption of and adherence to healthy behavior, promoting an active lifestyle, and increasing adherence to drug treatment [5,6].”
BackgroundBrørs, G., Pettersen, T. R., Hansen, T. B., Fridlund, B., Hølvold, L. B., Lund, H., & Norekvål, T. M. (2019) · BMC Health Services Research · doi:10.1186/s12913-019-4106-1 · Cited by 67
“Five studies reported HDL and LDL cholesterol levels [29, 33, 35, 40, 42].”
BackgroundInfluentialHodkinson, A., Kontopantelis, E., Adeniji, C., van Marwijk, H., McMillan, B., Bower, P., & Panagioti, M. (2019) · JAMA Network Open · doi:10.1001/jamanetworkopen.2019.12895 · Cited by 55
RetractedBraakhuis, H., Berger, M., & Bussmann, J. (2019) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-2522 · Cited by 51
“Effect estimates Authors were contacted when data on PA to calculate SMD post-intervention were missing (22, 24, 26, 29, 34, 35).”
BackgroundInfluentialThe Role of Wearable Technologies and Telemonitoring in Managing Vascular Disease
Chan, C., Sounderajah, V., Acharya, A., Normahani, P., Bicknell, C., & Riga, C. (2020) · Vascular and Endovascular Review · doi:10.15420/ver.2019.11 · Cited by 6
“used triaxial accelerometers (Yorbody) to monitor physical activity and set daily step-count prescriptions for patients with coronary artery disease enrolled in hospital-based cardiac rehabilitation.(13) This study found a significant improvement in lung function assessments and a trend towards fewer rehospitalisation…”
Method
Metadata
- Authors
- Frederix, I., Driessche, N. V., Hansen, D., Berger, J., Bonne, K., Alders, T., & Dendale, P.
- Venue
- European Journal of Preventive Cardiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2013-11-18
- Volume
- 22
- Issue
- 2
- Pages
- 150-158
- ISSN
- 2047-4873 (ISSN-L)
- 2047-4881
- OpenAlex
- W2331652840
- Cited by
- 106
- References
- 6
- FWCI
- 2.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.