Coffey, Sean, Lewandowski, Adam J, Garratt, Steve, Meijer, Rudy, Lynum, Steven, Bedi, Ram, Paterson, James, Yaqub, Mohammad, Noble, J Alison, Neubauer, Stefan, Petersen, Steffen E, Allen, Naomi, Sudlow, Cathie, Collins, Rory, Matthews, Paul M, Leeson, Paul · 2017 · European Journal of Preventive Cardiology
Cited by 48

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Background Ultrasound imaging is able to quantify carotid arterial wall structure for the assessment of cerebral and cardiovascular disease risks. We describe a protocol and quality assurance process to enable carotid imaging at large scale that has been developed for the UK Biobank Imaging Enhancement Study of 100,000 individuals. Design An imaging protocol was developed to allow measurement of carotid intima-media thickness from the far wall of both common carotid arteries. Six quality assurance criteria were defined and a web-based interface (Intelligent Ultrasound) was developed to facilitate rapid assessment of images against each criterion. Results and conclusions Excellent inter and intra-observer agreements were obtained for image quality evaluations on a test dataset from 100 individuals. The image quality criteria then were applied in the UK Biobank Imaging Enhancement Study. Data from 2560 participants were evaluated. Feedback of results to the imaging team led to improvement in quality assurance, with quality assurance failures falling from 16.2% in the first two-month period examined to 6.4% in the last. Eighty per cent had all carotid intima-media thickness images graded as of acceptable quality, with at least one image acceptable for 98% of participants. Carotid intima-media thickness measures showed expected associations with increasing age and gender. Carotid imaging can be performed consistently, with semi-automated quality assurance of all scans, in a limited timeframe within a large scale multimodality imaging assessment. Routine feedback of quality control metrics to operators can improve the quality of the data collection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/2047487317732273

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 48

Metadata

Authors
Coffey, S., Lewandowski, A. J., Garratt, S., Meijer, R., Lynum, S., Bedi, R., Paterson, J., Yaqub, M., Noble, J. A., Neubauer, S., Petersen, S. E., Allen, N., Sudlow, C., Collins, R., Matthews, P. M., & Leeson, P.
Venue
European Journal of Preventive Cardiology
Published
2017-09-19
Volume
24
Issue
17
Pages
1799-1806
ISSN
  • 2047-4873 (ISSN-L)
  • 2047-4881
OpenAlex
W2756379568
Cited by
48
References
5
FWCI
2.36
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.