CoChat

Adaptive design of a clinical decision support tool: What the impact on utilization rates means for future CDS research

Open access
Mann, Devin, Hess, Rachel, McGinn, Thomas, Mishuris, Rebecca, Chokshi, Sara, McCullagh, Lauren, Smith, Paul D., Palmisano, Joseph, Richardson, Safiya, Feldstein, David A. · 2019 · DIGITAL HEALTH
Cited by 29

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: We employed an agile, user-centered approach to the design of a clinical decision support tool in our prior integrated clinical prediction rule study, which achieved high adoption rates. To understand if applying this user-centered process to adapt clinical decision support tools is effective in improving the use of clinical prediction rules, we examined utilization rates of a clinical decision support tool adapted from the original integrated clinical prediction rule study tool to determine if applying this user-centered process to design yields enhanced utilization rates similar to the integrated clinical prediction rule study. MATERIALS & METHODS: We conducted pre-deployment usability testing and semi-structured group interviews at 6 months post-deployment with 75 providers at 14 intervention clinics across the two sites to collect user feedback. Qualitative data analysis is bifurcated into immediate and delayed stages; we reported on immediate-stage findings from real-time field notes used to generate a set of rapid, pragmatic recommendations for iterative refinement. Monthly utilization rates were calculated and examined over 12 months. RESULTS: We hypothesized a well-validated, user-centered clinical decision support tool would lead to relatively high adoption rates. Then 6 months post-deployment, integrated clinical prediction rule study tool utilization rates were substantially lower than anticipated based on the original integrated clinical prediction rule study trial (68%) at 17% (Health System A) and 5% (Health System B). User feedback at 6 months resulted in recommendations for tool refinement, which were incorporated when possible into tool design; however, utilization rates at 12 months post-deployment remained low at 14% and 4% respectively. DISCUSSION: Although valuable, findings demonstrate the limitations of a user-centered approach given the complexity of clinical decision support. CONCLUSION: Strategies for addressing persistent external factors impacting clinical decision support adoption should be considered in addition to the user-centered design and implementation of clinical decision support.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/2055207619827716

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 29

Metadata

Authors
Mann, D., Hess, R., McGinn, T., Mishuris, R., Chokshi, S., McCullagh, L., Smith, P. D., Palmisano, J., Richardson, S., & Feldstein, D. A.
Venue
DIGITAL HEALTH
Published
2019-01
Volume
5
Pages
2055207619827716-2055207619827716
ISSN
2055-2076 (ISSN-L)
OpenAlex
W2911510949
Cited by
29
References
7
FWCI
2.82
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Adaptive design of a clinical decision support tool: What the impact on utilization rates means for future CDS research. https://app.cochat.ai/papers/10.1177/2055207619827716
The paper
Mann, D., Hess, R., McGinn, T., Mishuris, R., Chokshi, S., McCullagh, L., Smith, P. D., Palmisano, J., Richardson, S., & Feldstein, D. A. (2019). Adaptive design of a clinical decision support tool: What the impact on utilization rates means for future CDS research. DIGITAL HEALTH. https://doi.org/10.1177/2055207619827716

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.