Optimal Use of Z -Scores to Preserve the Pulmonary Valve Annulus During Repair of Tetralogy of Fallot
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Objective: The size of the pulmonary annulus measured as a z-score is often used to determine when to insert a transannular patch (TAP). Multiple “cutoffs” are quoted in the literature; this could lead to inappropriate insertion. We aimed to determine whether the use of z-scores derived from different populations may have contributed to the varied “cutoffs” quoted. Methods: PubMed was searched using the terms: “tetralogy,” “Fallot,” “transannular,” “patch,” “mortality,” and “death.” Studies published between January 1, 2005, and October 5, 2017, were included; studies without participants under the age of 18 years and studies that did not describe the operative procedure were excluded. Results: Of 52 papers retrieved, 19 were included representing 2,500 repaired patients; 1,371 (54.8%) had a TAP. Five (26.3%) papers representing 638 patients (25.5%) quoted a z-score “cutoff” and what data set was used; “cutoffs” ranged from −2 to −4 and were derived from 2 different data sets. Three studies quoted a data set that has been shown in previous work to be problematic; the only quoted “cutoffs” of −4 were from two of these studies. Conclusions: Surprisingly few (26.3%) studies mention what pulmonary annulus size “cutoff” was used to decide when to insert a TAP. Z-scores derived from different populations were used by different studies and it is possible that this may have contributed to the varied “cutoffs’ quoted. Recommendations to perform valve-sparing surgery in pulmonary annuli as small as −4 may not be warranted. Future papers should record “cutoffs” employing recommended z-score data set.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Gatzoulis, M. A., Balaji, S., Webber, S. A., Siu, S. C., Hokanson, J. S., Poile, C., Rosenthal, M., Nakazawa, M., Moller, J. H., Gillette, P. C., et al. (2000) · The Lancet · doi:10.1016/s0140-6736(00)02714-8 · Cited by 1,779
Pettersen, M. D., Du, W., Skeens, M. E., & Humes, R. A. (2008) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.02.006 · Cited by 794
The Quantitative Anatomy of the Normal Child's Heart
Rowlatt, U. F., Rimoldi, H. J. A., & Lev, M. (1963) · Pediatric Clinics of North America · doi:10.1016/s0031-3955(16)31414-6 · Cited by 387
Daubeney, P. E. F., Blackstone, E. H., Weintraub, R. G., Slavik, Z., Scanlon, J., & Webber, S. A. (1999) · Cardiology in the Young · doi:10.1017/s1047951100005217 · Cited by 257
Cuypers, J. A. A. E., Menting, M. E., Konings, E. E. M., Opić, P., Utens, E. M. W. J., Helbing, W. A., Witsenburg, M., van den Bosch, A. E., Ouhlous, M., van Domburg, R. T., et al. (2014) · Circulation · doi:10.1161/circulationaha.114.009454 · Cited by 232
Tetralogy of Fallot: Results of a Pulmonary Valve-Sparing Strategy
Stewart, R. D., Backer, C. L., Young, L., & Mavroudis, C. (2005) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2005.04.016 · Cited by 215
Kirklin, J., Blackstone, E., Jonas, R., Shimazaki, Y., Kirklin, J., Mayer, J., Pacifico, A., & Castañeda, A. R. (1992) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)34954-2 · Cited by 132
Early Primary Repair of Tetralogy of Fallot in Neonates and Infants Less Than Four Months of Age
Tamesberger, M. I., Lechner, E., Mair, R., Hofer, A., Sames-Dolzer, E., & Tulzer, G. (2008) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2008.07.019 · Cited by 124
Symptomatic neonatal tetralogy of Fallot: repair or shunt?
Kanter, K. R., Kogon, B. E., Kirshbom, P. M., & Carlock, P. R. (2010) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2009.12.060 · Cited by 110
Zilberman, M. V., Khoury, P. R., & Kimball, R. T. (2004) · Pediatric Cardiology · doi:10.1007/s00246-004-0736-z · Cited by 106
Kolcz, J., & Pizarro, C. (2005) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2005.05.014 · Cited by 84
Chiu, S.-N., Wang, J.-K., Chen, H.-C., Lin, M.-T., Wu, E.-T., Chen, C.-A., Huang, S.-C., Chang, C.-I., Chen, Y.-S., Chiu, I.-S., et al. (2012) · Circulation: Cardiovascular Quality and Outcomes · doi:10.1161/circoutcomes.111.963603 · Cited by 82
Boni, L., García, E., Galletti, L., Pérez, A., Herrera, D., Ramos, V., Marianeschi, S. M., & Comas, J. V. (2009) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2009.01.016 · Cited by 81
Long-term outcomes of transatrial-transpulmonary repair of tetralogy of Fallot.
Luijten, L. W. G., van den Bosch, E., Duppen, N., Tanke, R., Roos-Hesselink, J., Nijveld, A., van Dijk, A., Bogers, A. J. J. C., van Domburg, R., & Helbing, W. A. (2015) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezu182 · Cited by 72
Early Primary Repair of Tetralogy of Fallot
Jonas, R. A. (2009) · Seminars in Thoracic and Cardiovascular Surgery: Pediatric Cardiac Surgery Annual · doi:10.1053/j.pcsu.2009.01.021 · Cited by 70
Kim, H., Sung, S. C., Kim, S.-H., Chang, Y. H., Lee, H. D., Park, J. A., & Lee, Y. S. (2013) · Interactive CardioVascular and Thoracic Surgery · doi:10.1093/icvts/ivt361 · Cited by 59
Sen, D. G., Najjar, M., Yimaz, B., Levasseur, S. M., Kalessan, B., Quaegebeur, J. M., & BACHA, E. A. (2016) · Pediatric Cardiology · doi:10.1007/s00246-016-1355-1 · Cited by 58
d’Udekem, Y., Galati, J. C., Rolley, G. J., Konstantinov, I. E., Weintraub, R. G., Grigg, L., Ramsay, J., Wheaton, G. R., Hope, S. A., Cheung, M. M. H., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.10.011 · Cited by 53
Tetralogy of Fallot repair: optimal z-score use for transannular patch insertion
Awori, M. N., Leong, W., Artrip, J. H., & O’Donnell, C. P. (2012) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezs372 · Cited by 50
Self-citationEarly results after transatrial/transpulmonary repair of tetralogy of Fallot
Giannopoulos, N. (2002) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/s1010-7940(02)00403-7 · Cited by 45
Neither age at repair nor previous palliation affects outcome in tetralogy of Fallot repair
Mimic, B., Brown, K., Oswal, N., Simmonds, J., Hsia, T., Tsang, V. T., de Leval, M. R., & Kostolny, M. (2013) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezt307 · Cited by 40
Factors affecting perioperative mortality in tetralogy of Fallot
Saygi, M., Ergul, Y., Tola, H. T., Ozyilmaz, I., Ozturk, E., Onan, I. S., Haydin, S., Erek, E., Yeniterzi, M., Guzeltas, A., et al. (2015) · Pediatrics International · doi:10.1111/ped.12627 · Cited by 29
Optimal Z -Score Use in Surgical Decision-Making in Pulmonary Atresia With Intact Ventricular Septum
Awori, M. N., Mehta, N. P., Mitema, F. O., & Kebba, N. (2017) · World Journal for Pediatric and Congenital Heart Surgery · doi:10.1177/2150135117701407 · Cited by 28
Self-citationÖzkara, A., Mert, M., Cetin, G., Saltık, L., & Sarıoğlu, T. (2006) · Journal of Cardiac Surgery · doi:10.1111/j.1540-8191.2006.00192.x · Cited by 19
Gerling, C., Rukosujew, A., Kehl, H.-G., Tjan, T. D. T., Hoffmeier, A., Vogt, J., Scheld, H.-H., & Krasemann, T. (2009) · Herz Kardiovaskuläre Erkrankungen · doi:10.1007/s00059-009-3169-x · Cited by 15
Pulmonary cusp augmentation in repair of tetralogy of Fallot
Attanawanich, S., Ngodgnamthaweesuk, M., Kitjanon, N., & Sitthisombat, C. (2013) · Asian Cardiovascular and Thoracic Annals · doi:10.1177/0218492312444284 · Cited by 15
Tetralogy of Fallot with subarterial ventricular septal defect: Surgical outcome in the current era
Varghese, R., Devendran, V., Anjith, P., Singhi, A. K., Jesudian, V., Sheriff, E., & Sivakumar, K. (2015) · Annals of Pediatric Cardiology · doi:10.4103/0974-2069.149511 · Cited by 12
Optimal Normative Pediatric Cardiac Structure Dimensions for Clinical Use
Awori, M. N., Finucane, K. A., & Gentles, T. L. (2010) · World Journal for Pediatric and Congenital Heart Surgery · doi:10.1177/2150135110386500 · Cited by 12
Self-citationHe, G. (2008) · Journal of Cardiac Surgery · doi:10.1111/j.1540-8191.2008.00700.x · Cited by 12
Seddio, F., Migliazza, L., Borghi, A., & Crupi, G. (2007) · Journal of Cardiovascular Medicine · doi:10.2459/01.jcm.0000260214.27450.c9 · Cited by 12
Prosthetic reconstruction of bicuspid pulmonary valve in tetralogy of Fallot
Sasikumar, N., Ramanan, S., Rema, K. M. S., Kumar, R. S., Subramanyan, R., & Cherian, K. M. (2013) · Asian Cardiovascular and Thoracic Annals · doi:10.1177/0218492313496416 · Cited by 11
Risk factors for QRS prolongation after repaired tetralogy of Fallot.
Galea, N., Aquilina, O., & Grech, V. (2006) · PubMed · Cited by 5
Research works printed but not linked: 3
- Hua Z, 2011, Eur J Cardiothorac Surg, 40, 1221
- Hashemzadeh K, 2010, Acta Med Iran, 48, 117
- Galea N, 2006, Hellenic J Cardiol, 47, 66
Cited by
Miller, J. R., Stephens, E. H., Goldstone, A. B., Glatz, A. C., Kane, L., Arsdell, G. S. V., Stellin, G., Barron, D. J., d’Udekem, Y., Benson, L. N., et al. (2022) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2022.07.025 · Cited by 98
Blais, S., Marelli, A., Vanasse, A., Dahdah, N., Dancea, A., Drolet, C., & Dallaire, F. (2021) · JAMA Network Open · doi:10.1001/jamanetworkopen.2021.18141 · Cited by 67
Sinha, R., Gooty, V. D., Jang, S., Dodge‐Khatami, A., & Salazar, J. D. (2019) · Children · doi:10.3390/children6050067 · Cited by 16
“PV annulus Z-score correlates, derived from preoperative transthoracic echocardiography measurements, have played a vital role in this decision-making process, and a score below −2 has been commonly referenced as a “cut-off” point for the insertion of a TAP [2].”
BackgroundBlais, S., Marelli, A. J., Vanasse, A., Dahdah, N., Dancea, A., Drolet, C., & Dallaire, F. (2020) · CJC Open · doi:10.1016/j.cjco.2020.06.012 · Cited by 14
“This strategy has been associated with favourable outcomes when the pulmonary valve annulus is well developed(6,7) but could result in significant residual pulmonary stenosis in patients with an underdeveloped valve.(8-10) There have been studies on the short-term effect of both surgical strategies, but the long-term…”
BackgroundValue of pulmonary annulus index in predicting transannular patch in tetralogy of Fallot repair
Lyu, Z., Jin, M., & Yang, Y. (2021) · Journal of Cardiac Surgery · doi:10.1111/jocs.15500 · Cited by 9
“Awori et al.(21) proposed that TAP occurs when the pulmonary annulus Z score <−4.”
Background
Metadata
- Authors
- Awori, M. N., Mehta, N. P., Mitema, F. O., & Kebba, N.
- Affiliations
- University of Nairobi (KE)
- Corresponding author
- Awori, Mark Nelson
- Venue
- World Journal for Pediatric and Congenital Heart Surgery
- Publisher
- SAGE Publications
- Published
- 2018-04-25
- Volume
- 9
- Issue
- 3
- Pages
- 285-288
- ISSN
- 2150-1351 (ISSN-L)
- 2150-136X
- OpenAlex
- W2800556121
- Cited by
- 18
- References
- 32
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 2 · 2023: 3 · 2022: 2 · 2021: 3 · 2020: 2 · 2019: 1
- FWCI
- 0.21
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- World Journal for Pediatric and Congenital Heart Surgery (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Congenital Heart Disease Studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Valve Diseases and Treatments
- Health Sciences › Medicine › Surgery › Pectus Deformity Diagnosis and Treatment
- Keywords
- tetralogy of Fallot, pulmonary valve annulus, Z-score, transannular patch, pulmonary regurgitation, congenital heart surgery outcomes
- MeSH terms
- Humans, Pulmonary Valve, Retrospective Studies, Tetralogy of Fallot, Treatment Outcome
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.