An On-Chip Small Intestine–Liver Model for Pharmacokinetic Studies
Open accessAbstract
Testing of drug effects and cytotoxicity by using cultured cells has been widely performed as an alternative to animal testing. However, the estimation of pharmacokinetics by conventional cell-based assay methods is difficult because of the inability to evaluate multiorgan effects. An important challenge in the field is to mimic the organ-to-organ network in the human body by using a microfluidic network connecting small-scale tissues based on recently emerging MicroTAS (Micro Total Analysis Systems) technology for prediction of pharmacokinetics. Here, we describe an on-chip small intestine-liver coupled model for pharmacokinetic studies. To construct an in vitro pharmacokinetic model that appropriately models in vivo conditions, physiological parameters such as the structure of internal circulation, volume ratios of each organ, and blood flow ratio of the portal vein to the hepatic artery were mimicked using microfluidic networks. To demonstrate interactions between organs in vitro in pharmacokinetic studies, Caco-2, HepG2, and A549 cell cultures were used as organ models of the small intestine, liver, and lung, respectively, and connected to each other through a microporous membrane and microchannels to prepare a simple model of a physiological organ-to-organ network. The on-chip organ model assay using three types of substrate-epirubicine (EPI), irinotecan (CPT-11), and cyclophosphamide (CPA)-were conducted to model the effects of orally administered or biologically active anticancer drugs. The result suggested that the device can replicate physiological phenomena such as activity of the anticancer drugs on the target cells. This microfluidic device can thus be used as an in vitro organ model to predict the pharmacokinetics of drugs in the human body and may thus provide not only an alternative to animal testing but also a method of obtaining parameters for in silico models of physiologically based pharmacokinetics.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Some microfluidic devices integrated multiple chambers with different types of cells to measure PK and PD properties of drug compounds in vitro.
“Some devices integrated multiple chambers with different types of cells to measure PK and pharmacodynamics (PD) properties of drug compounds in vitro.35, 36, 37”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [35]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Baker, M. (2011) · Nature · doi:10.1038/471661a · Cited by 188 · see citing works
Imura, Y., Sato, K., & Yoshimura, E. (2010) · Analytical Chemistry · doi:10.1021/ac100806x · Cited by 172 · see citing works
Flagged first, then by citations
Research works printed but not linked: 39
- Yanagita, T. Some Methodological Problems in Assessing Dependence-Producing Properties of Drugs in Animals. Pharmacol. Rev. 1975, 27, 503-509.
- Eisenbrand, G.; Pool-Zobel, B.; Baker, V.; et al. Methods of In Vitro Toxicology. Food Chem. Toxicol. 2002, 40, 193-236.
- Inamdar, N. K.; Borenstein, J. T. Microfluidic Cell Culture Models for Tissue Engineering. Curr. Opin. Biotechnol. 2011, 22, 681-689.
- Huh, D.; Torisawa, Y. S.; Hamilton, G. A.; et al. Microengineered Physiological Biomimicry: Organs-on- Chips. Lab Chip 2012, 12, 2156-2164.
- Kane, B. J.; Zinner, M. J.; Yarmush, M. L.; et al. Liver- Specific Functional Studies in a Microfluidic Array of Primary Mammalian Hepatocytes. Anal. Chem. 2006, 78, 4291-4298.
- Lee, P. J.; Hung, P. J.; Lee, L. P. An Artificial Liver Sinusoid with a Microfluidic Endothelial-Like Barrier for Primary Hepatocyte Culture. Biotechnol. Bioeng. 2007, 97, 1340-1346.
- Nakao, Y.; Kimura, H.; Sakai, Y.; et al. Bile Canaliculi Formation by Aligning Rat Primary Hepatocytes in a Microfluidic Device. Biomicrofluidics 2011, 5, 22212.
- Huh, D.; Fujioka, H.; Tung, N.; et al. Acoustically Detectable Cellular-Level Lung Injury Induced by Fluid Mechanical Stresses in Microfluidic Airway Systems. Proc. Natl. Acad. Sci. U. S. A. 2007, 104, 18886-18891.
- Huh, D.; Matthews, B. D.; Mammoto, A.; et al. Reconstituting Organ-Level Lung Functions on a Chip. Science 2010, 328, 1662-1668.
- Jang, K. J.; Suh, K. Y. A Multi-Layer Microfluidic Device for Efficient Culture and Analysis of Renal Tubular Cells. Lab Chip 2010, 10, 36-42.
- Imura, Y.; Yoshimura, E.; Sato, K. Microcirculation System with a Dialysis Part for Bioassays Evaluating Anticancer Activity and Retention. Anal. Chem. 2013, 85, 1683-1638.
- Kimura, H.; Yamamoto, T.; Sakai, H.; et al. An Integrated Microfluidic System for Long-Term Perfusion Culture and On-Line Monitoring of Intestinal Tissue Models. Lab Chip 2008, 8, 741-746.
- Imura, Y.; Asano, Y.; Sato, K.; et al. A Microfluidic System to Evaluate Intestinal Absorption. Anal. Sci. 2009, 25, 1403-1407.
- You, L.; Temiyasathit, S.; Lee, P.; et al. Osteocytes as Mechanosensors in the Inhibition of Bone Resorption Due to Mechanical Loading. Bone 2008, 42, 172-179.
- Puleo, C. M.; McIntosh Ambrose, W.; Takezawa, T.; et al. Integration and Application of Vitrified Collagen in Multilayered Microfluidic Devices for Corneal Microtissue Culture. Lab Chip 2009, 9, 3221-3227.
- Song, J. W.; Cavnar, S. P.; Walker, A. C.; et al. Microfluidic Endothelium for Studying the Intravascular Adhesion of Metastatic Breast Cancer Cells. PLoS One 2009, 4, e5756.
- Baudoin, R.; Corlu, A.; Griscom, L.; et al. Trends in the Development of Microfluidic Cell Biochips for In Vitro Hepatotoxicity. Toxicol. In Vitro 2007, 21, 535-544.
- Sung, J. H.; Shuler, M. L. A Micro Cell Culture Analog (microCCA) with 3-D Hydrogel Culture of Multiple Cell Lines to Assess Metabolism-Dependent Cytotoxicity of Anti- Cancer Drugs. Lab Chip 2009, 9, 1385-1394.
- Sung, J. H.; Kam, C.; Shuler, M. L. A Microfluidic Device for a Pharmacokinetic-Pharmacodynamic (PK-PD) Model on a Chip. Lab Chip 2010, 10, 446-455.
- Sung, J. H.; Esch, M. B.; Prot, J. M.; et al. Microfabricated Mammalian Organ Systems and Their Integration into Models of Whole Animals and Humans. Lab Chip 2013, 13, 1201-1212.
- Roig-Pérez, S.; Moretó, M.; Ferrer, R. Transepithelial Taurine Transport in Caco-2 Cell Monolayers. J. Membrane Biol. 2005, 204, 85-92.
- Barthe, L.; Woodley, J.; Houin, G. Gastrointestinal Absorption of Drugs: Methods and Studies. Fundamental Clin. Pharmacol. 1999, 13, 154-168.
- Wynne, H. A.; Cope, L. H.; Mutch, E.; et al. The Effect of Age upon Liver Volume and Apparent Liver Blood Flow in Healthy Man. Hepatology 1989, 9, 297-301.
- Twelves, C. J.; Dobbs, N. A.; Michael, Y.; et al. Clinical Pharmacokinetics of Epirubicin: The Importance of Liver Biochemistry Tests. Br. J. Cancer 1992, 66, 765-769.
- Humerickhouse, R.; Lohrbach, K.; Li, L.; et al. Characterization of CPT-11 Hydrolysis by Human Liver Carboxylesterase Isoforms hCE-1 and hCE-2. Cancer Res. 2000, 60, 1189-1192.
- Mirkes, P. E. Cyclophosphamide Teratogenesis: A Review. Teratog. Carcinog. Mutagen. 1985, 5, 75-88.
- Powers, M. J.; Domansky, K.; Kaazempur-Mofrad, M. R.; et al. A Microfabricated Array Bioreactor for Perfused 3D Liver Culture. Biotechnol. Bioeng. 2002, 78, 257-269.
- Tilles, A. W.; Baskaran, H.; Roy, P.; et al. Effects of Oxygenation and Flow on the Viability and Function of Rat Hepatocytes Cocultured in a Microchannel Flat-Plate Bioreactor. Biotechnol. Bioeng. 2001, 73, 379-389.
- Xu, H.; Wu, J.; Chu, C. C.; et al. Development of Disposable PDMS Micro Cell Culture Analog Devices with Photopolymerizable Hydrogel Encapsulating Living Cells. Biomed. Microdevices 2012, 14, 409-418.
- Choi, S. H.; Nishikawa, M.; Sakoda, A.; et al. Feasibility of a Simple Double-Layered Coculture System Incorporating Metabolic Processes of the Intestine and Liver Tissue: Application to the Analysis of Benzo[A]Pyrene Toxicity. Toxicol. In Vitro 2004, 18, 393-402.
- Leclerc, E.; Sakai, Y.; Fujii, T. Perfusion Culture of Fetal Human Hepatocytes in Microfluidic Environments. Biochem. Eng. J. 2004, 20, 143-148.
- Kimura, H.; Nishikawa, M.; Yamamoto, T.; Sakai, Y.; Fujii, T. Microfluidic Perfusion Culture of Human Hepatocytes. J. Robot. Mechatronics 2007, 19, 550-556.
- Maruichi, T.; Fukami, T.; Nakajima, M.; et al. Transcriptional Regulation of Human Carboxylesterase 1A1 by Nuclear Factor-Erythroid 2 Related Factor 2 (Nrf2). Biochem. Pharmacol. 2010, 79, 288-295.
- Ocker, M.; Alajati, A.; Ganslmayer, M.; et al. The Histone- Deacetylase Inhibitor SAHA Potentiates Proapoptotic Effects of 5-Fluorouracil and Irinotecan in Hepatoma Cells. J. Cancer Res. Clin. Oncol. 2005, 131, 385-394.
- Martin, P.; Riley, R.; Back, D. J.; et al. Comparison of the Induction Profile for Drug Disposition Proteins by Typical Nuclear Receptor Activators in Human Hepatic and Intestinal Cells. Br. J. Pharmacol. 2008, 153, 805-819.
- Westerink, W. M. A.; Schoonen, W. G. E. J. Cytochrome P450 Enzyme Levels in HepG2 Cells and Cryopreserved Primary Human Hepatocytes and Their Induction in HepG2 Cells. Toxicol. In Vitro 2007, 21, 1581-1591.
- Okumura, M.; Iwakiri, T.; Takagi, A.; et al. Hepatocyte Growth Factor Suppresses the Anticancer Effect of Irinotecan by Decreasing the Level of Active Metabolite in HepG2 Cells. Biochem. Pharmacol. 2011, 82, 1720-1730.
- Yanagida, A.; Ito, K.; Chikada, H.; et al. An In Vitro Expansion System for Generation of Human iPS Cell-Derived Hepatic Progenitor-Like Cells Exhibiting a Bipotent Differentiation Potential. PLoS One 2013, 8, e67541.
- Kimura, H.; Takeyama, H.; Komori, K.; Yamamoto, T.; Sakai, Y.; Fujii, T. Microfluidic Device with Integrated Glucose Sensor for Cell-Based Assay in Toxicology. J. Robot. Mechatronics 2010, 22, 594-600.
Cited by
Sorted by citations
Organs-on-a-Chip: A Fast Track for Engineered Human Tissues in Drug Development
Ronaldson-Bouchard, K., & Vunjak-Novakovic, G. (2018) · Cell Stem Cell · doi:10.1016/j.stem.2018.02.011 · Cited by 657 · see citing works
Microfluidic Organ-on-a-Chip Models of Human Intestine
Bein, A., Shin, W., Jalili-Firoozinezhad, S., Park, M. H., Sontheimer-Phelps, A., Tovaglieri, A., Chalkiadaki, A., Kim, H. J., & Ingber, D. E. (2018) · Cellular and Molecular Gastroenterology and Hepatology · doi:10.1016/j.jcmgh.2017.12.010 · Cited by 601 · see citing works
Organ/body-on-a-chip based on microfluidic technology for drug discovery
Kimura, H., Sakai, Y., & Fujii, T. (2018) · Drug Metabolism and Pharmacokinetics · doi:10.1016/j.dmpk.2017.11.003 · Cited by 435 · see citing works
Self-citationTsamandouras, N., Chen, W. L. K., Edington, C. D., Stokes, C. L., Griffith, L. G., & Cirit, M. (2017) · The AAPS Journal · doi:10.1208/s12248-017-0122-4 · Cited by 222 · see citing works
Engineered Liver Platforms for Different Phases of Drug Development
Ware, B. R., & Khetani, S. R. (2017) · Trends in Biotechnology · doi:10.1016/j.tibtech.2016.08.001 · Cited by 90 · see citing works
Microfluidic Liver-on-a-Chip for Preclinical Drug Discovery
Fu, J., Qiu, H., & Tan, C. S. (2023) · Pharmaceutics · doi:10.3390/pharmaceutics15041300 · Cited by 42 · see citing works
- Authors
- Kimura, H., Ikeda, T., Nakayama, H., Sakai, Y., & Fujii, T.
- Affiliations
- Tokai University (JP)
- Institute of Industrial Science, The University of Tokyo (JP)
- Japan Science and Technology Agency (JP)
- Corresponding author
- Fujii, Teruo
- Venue
- SLAS Technology
- Publisher
- Elsevier BV
- Published
- 2015-06
- Volume
- 20
- Issue
- 3
- Pages
- 265-273
- ISSN
- 2472-6303 (ISSN-L)
- OpenAlex
- W1985789373
- Cited by
- 136
- References
- 2
- Citations by year
- 2026: 6 · 2025: 7 · 2024: 17 · 2023: 16 · 2022: 12 · 2021: 18 · 2020: 12 · 2019: 15 · 2018: 10 · 2017: 13 · 2016: 7 · 2015: 3
- FWCI
- 3.98
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- SLAS TECHNOLOGY (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Funders
- Japan Society for the Promotion of Science (26390039, CREST)
- Core Research for Evolutional Science and Technology
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Keywords
- pharmacokinetics, organ-on-a-chip, Caco-2 cells, HepG2 cells, A549 cells, epirubicin, irinotecan, cyclophosphamide, anticancer agents, physiologically based pharmacokinetic modeling, alternatives to animal testing, drug metabolism
- MeSH terms
- Irinotecan, Animals, Camptothecin, Computer Simulation, Cyclophosphamide, Drug Screening Assays, Antitumor, Humans, Intestine, Small, Liver, Liver Neoplasms, Lung, Lung Neoplasms, Organ Culture Techniques, Stomach Neoplasms, Epirubicin, Caco-2 Cells, Lab-On-A-Chip Devices, Hep G2 Cells
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review