Patellar Tracking during the Gait Cycle
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index; none of the 17 sources its claims cite is checked for support yet.
Abstract
PURPOSE: To assess normal patellar tracking during walking using the 9-camera infrared system. METHODS: Four men and 6 women aged 25 to 33 (mean, 29) years each performed 16 walking trials on one occasion. They had prominent patellae with minimal soft tissues (minimising skin artefacts), and their knees and lower limbs were normal and symmetrical. 12 retro-reflective markers (2.5 cm in diameter) were taped to anatomic landmarks of the lower body. Two additional markers (1.4 cm in diameter) were first placed on the medial and lateral points and then proximal and distal points of the patella. Patellar motion relative to the centre of the knee joint was defined as angles between the centre of the knee joint and the 2 sets of patellar markers (medial-lateral and proximal-distal). The mean, maximum, and minimum values of these angles in a standing position were recorded, as was patellar tracking during walking. The X, Y, and Z coordinates for each marker were smoothed out throughout the capturing time. A single gait cycle per trial was chosen for analysis. RESULTS: During walking, the centre of the knee joint and the patella did not move in unison, and the extent of separation was subject dependent. In 70% of the participants, the maximum angle between the centre of the knee joint and each set of markers occurred in the swing phase (0-43%) of the gait cycle. When analysing both sets of markers together, the percentage of participants became 60%. The extent of knee flexion was subject dependent. There was more medial-lateral motion (shift) of the patella than proximal-distal (tilt) motion during the gait cycle. These indicated that the maximum amount of patellar shift and tilt occurred in the swing and early stance phases of the gait cycle and that abnormal patellar motion can be detected if excessive shift or tilt occurs outside of these phases. CONCLUSION: Patella mal-tracking could be attributed to the position of the lower body segments rather than the absorption or generation of forces.
Overview
CoChat Summary
TL;DR
This study used a 9-camera infrared system to assess normal patellar tracking during barefoot walking in 10 healthy adults. The patella and knee-joint centre did not move in unison; maximum patellar shift/tilt occurred mainly in swing and early stance, with more medial-lateral shift than proximal-distal tilt.
Key findings
- During walking, the centre of the knee joint and the patella did not move in unison, and the extent of separation was subject dependent.
- In 70% of participants, the maximum angle between the centre of the knee joint and each set of patellar markers occurred in the swing phase (0–43% of gait cycle); when both marker sets were analysed together, this was 60%.
- There was more medial-lateral motion (shift) than proximal-distal motion (tilt) of the patella during the gait cycle; maximum patellar shift and tilt occurred in the swing and early stance phases.
- At times of maximum and minimum angles, knee flexion was >20º in 60–70% of participants and <15º in 80% (<24º in all), respectively. The authors concluded patella mal-tracking could be attributed to lower-body segment position rather than force absorption/generation.
Methods
- Pilot reliability study: one 31-year-old man (86 kg, 1.8 m) performed 10 walking trials on each of 8 separate occasions; coefficient of variation for patellar motion relative to the knee-joint centre within and between sessions was <1%.
- Main study: 4 men and 6 women aged 25–33 (mean 29) years, mean weight 64 (SD 14) kg and height 1.73 (SD 0.11) m, each performed 16 barefoot walking trials on one occasion; participants had prominent patellae with minimal soft tissues and normal, symmetrical knees/lower limbs.
- 12 retro-reflective markers (2.5 cm) were placed on lower-body landmarks; two additional markers (1.4 cm) were placed on medial/lateral and proximal/distal patellar points. A 9-camera infrared system (Vicon 612) recorded patellar motion relative to the knee-joint centre as angles between the centre and the two marker sets; coordinates were smoothed with Woltring’s spline, joint centres generated with PluginGait, and one gait cycle per trial analysed.
Limitations
- The paper states further research is required to separate patellar tracking into two planes for assessing tilt and shift.
- The authors state they should have considered both walking speed and gender when analysing patella mal-tracking during walking.
- Evident from the text: the main sample was small (10 healthy young adults) and selected for prominent patellae with minimal soft tissues; only one gait cycle per trial was analysed, and findings may not generalize to patients with patellofemoral pain syndrome or other populations.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 17 Not checked · 20 Own results and interpretations
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“During walking, the centre of the knee joint and the patella did not move in unison”
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on an assumption not shown here.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“During the gait cycle, there was more medial-lateral motion (shift) of the patella than proximal-distal (tilt) motion.”
§ Patellar Tracking during the Gait Cycle > results
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on an assumption not shown here.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“In 70% of the participants, the maximum angle between the centre of the knee joint and each set of markers occurred in the swing phase (0-43%) of the gait cycle.”
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on an assumption not shown here.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“the extent of separation was subject dependent”
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on an assumption not shown here.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The extent of knee flexion was subject dependent.”
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
19 more claims
Create a free account to see all 37 claims and to verify the 15 references still open.
- The quote only partly states this claim. 1
- It may state two separate claims as one. 8
- Probably not a substantial claim. 6
Citations
Cites
A gait analysis data collection and reduction technique
Davis, R. B., Õunpuu, S., Tyburski, D., & Gage, J. R. (1991) · Human Movement Science · doi:10.1016/0167-9457(91)90046-z · Cited by 3,086
The biomechanics and motor control of human gait : normal, elderly and pathological
Winter, D. A. (1991) · University of Waterloo Press eBooks · Cited by 1,428
The biomechanics and motor control of human gait: Normal, elderly, and pathological
Brand, R. A. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90236-t · Cited by 1,103
Basic gait parameters: reference data for normal subjects, 10-79 years of age.
Öberg, T., Karsznia, A., & Öberg, K. (1993) · PubMed · Cited by 832
The influence of muscles on knee flexion during the swing phase of gait
Piazza, S. J., & Delp, S. L. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00144-1 · Cited by 333
Three–Dimensional Lower Extremity Joint Kinetics in Normal Pediatric Gait
Ounpuu, S., Gage, J. R., & Davis, R. B. (1991) · Journal of Pediatric Orthopaedics · doi:10.1097/01241398-199105000-00012 · Cited by 289
Measurement of Patellar Tracking: Assessment and Analysis of the Literature
Katchburian, M. V., Bull, A. M. J., Shih, Y.-F., Heatley, F. W., & Amis, A. A. (2003) · Clinical Orthopaedics & Related Research · doi:10.1097/01.blo.0000068767.86536.9a · Cited by 273
The three‐dimensional tracking pattern of the human patella
van Kampen, A., & Huiskes, R. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080309 · Cited by 228
The biomechanics of the human patella during passive knee flexion
Heegaard, J., Leyvraz, P. F., Curnier, A., Rakotomanana, L., & Huiskes, R. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00059-q · Cited by 180
Joint angle parameters in gait: reference data for normal subjects, 10-79 years of age.
Öberg, T., Karsznia, A., & Öberg, K. (1994) · PubMed · Cited by 178
Applied Biomechanics of the Patella
Grelsamer, R. P., & Weinstein, C. H. (2001) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200108000-00003 · Cited by 169 · cited 1×
“uk Journal of Orthopaedic Surgery 2011;19(3):288-91”
In vivo tracking of the human patella
Koh, T. J., Grabiner, M. D., & De Swart, R. J. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90105-a · Cited by 98
Gait study of patients with patellofemoral pain syndrome
Nadeau, S., Gravel, D., Hébert, L. J., Arsenault, A. B., & Lepage, Y. (1997) · Gait & Posture · doi:10.1016/s0966-6362(96)01078-8 · Cited by 74
Patellofemoral complications in symmetrical total knee arthroplasty
Harwin, S. F. (1998) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(98)90026-2 · Cited by 62
Real-time measurement of patellofemoral kinematics in asymptomatic subjects
Laprade, J., & Lee, R. (2004) · The Knee · doi:10.1016/j.knee.2004.02.004 · Cited by 57
Clinical biomechanics of the patellofemoral joint
Garth, W. P. (2001) · Operative Techniques in Sports Medicine · doi:10.1053/otsm.2001.25160 · Cited by 4
Cited by
Watari, R., Kobsar, D., Phinyomark, A., Osis, S. T., & Ferber, R. (2016) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2016.08.003 · Cited by 47
Carnesecchi, O., Philippot, R., Boyer, B., Farizon, F., & Édouard, P. (2014) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-014-3347-0 · Cited by 15
“In a study on patellar tracking during the gait cycle, Abbas and Diss [1] found there was more medial–lateral motion (shift) of the patella than proximal–distal (tilt) motion during running especially in the early degrees of knee flexion up to the patella engagement in the femoral trochlea and corresponding to the mot…”
BackgroundMansfield, P. J., & Neumann, D. A. (2018) · Elsevier eBooks · doi:10.1016/b978-0-323-54498-6.00012-6 · Cited by 7
Rath, B., Asseln, M., Betsch, M., Prescher, A., Tingart, M., & Eschweiler, J. (2018) · BioMed Research International · doi:10.1155/2018/7189714 · Cited by 2
“Limitations of cadaveric studies are associated with the difficulty in simulating physiological muscle forces of activemotion [7].”
BackgroundStabile, R. (2018) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.71.2018.tde-03012018-141151 · Cited by 9
Metadata
- Authors
- Abbas, G., & Diss, C.
- Affiliations
- Royal Cornwall Hospital Trust (GB)
- University of Roehampton (GB)
- Corresponding author
- Abbas, Ghulam
- ORCID
- Diss, Ceri
- Venue
- Journal of orthopaedic surgery
- Publisher
- SAGE Publications
- Published
- 2011-12
- Volume
- 19
- Issue
- 3
- Pages
- 288-291
- ISSN
- 1022-5536 (ISSN-L)
- 2309-4990
- OpenAlex
- W2137827036
- Cited by
- 9
- References
- 16
- Citations by year
- 2026: 2 · 2022: 1 · 2021: 1 · 2018: 3 · 2016: 1 · 2014: 1
- FWCI
- 0.17
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of orthopaedic surgery (publishedVersion)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- University of Roehampton
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
- Health Sciences › Medicine › Surgery › Knee injuries and reconstruction techniques
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- patellar tracking, patellar shift, patellar tilt, gait cycle, knee joint, walking, patellar maltracking, swing phase, knee flexion
- MeSH terms
- Adult, Biomechanical Phenomena, Female, Gait, Humans, Knee Joint, Male, Patella, Walking
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.