CoChat

Investigating the Reliability of Pupillometry as a Measure of Individualized Listening Effort

Neagu, Mihaela-Beatrice, Kressner, Abigail A., Relaño-Iborra, Helia, Bækgaard, Per, Dau, Torsten, Wendt, Dorothea · 2023 · Trends in Hearing
Cited by 28

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Abstract

Recordings of the pupillary response have been used in numerous studies to assess listening effort during a speech-in-noise task. Most studies focused on averaged responses across listeners, whereas less is known about pupil dilation as an indicator of the individuals’ listening effort. The present study investigated the reliability of several pupil features as potential indicators of individual listening effort and the impact of different normalization procedures on the reliability. The pupil diameters of 31 normal-hearing listeners were recorded during multiple visits while performing a speech-in-noise task. The signal-to-noise ratios (SNRs) of the stimuli ranged from [Formula: see text]12 dB to [Formula: see text]4 dB. All listeners were measured twice at separate visits, and 11 were re-tested at a third visit. To examine the reliability of the pupil responses across visits, the intraclass correlation coefficient was applied to the peak and mean pupil dilation and to the temporal features of the pupil response, extracted using growth curve analysis. The reliability of the pupillary response was assessed in relation to SNR and different normalization procedures over multiple visits. The most reliable pupil features were the traditional mean and peak pupil dilation. The highest reliability results were obtained when the data were baseline-corrected and normalized to the individual pupil response range across all visits. Moreover, the present study results showed only a minor impact of the SNR and the number of visits on the reliability of the pupil response. Overall, the results may provide an important basis for developing a standardized test for pupillometry in the clinic.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/23312165231153288

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 37

  1. 10.1007/s10339-018-0886-1 · DOI
  2. 10.1523/JNEUROSCI.3010-18.2019 · DOI
  3. 10.1146/annurev.neuro.28.061604.135709 · DOI · Paper page
  4. 10.3758/BF03329118 · DOI
  5. 10.17265/2159-5313/2016.09.003 · DOI · Paper page
  6. 10.1007/s10286-009-0515-2 · DOI
  7. 10.1037/1040-3590.6.4.284 · DOI · Paper page
  8. Daguet I., 2019, Frontiers in Neurology, 10, 10.3389/fneur.2019.00108 · DOI
  9. 10.1097/AUD.0000000000000028 · DOI · Paper page
  10. 10.1037/0882-7974.12.3.479 · doi:10.1037/0882-7974.12.3.479 · Paper page
  11. 10.1002/wcs.1514 · DOI · Paper page
  12. Giuliani N. P., Brown C. J., Wu Y. H. (2020). Comparisons of the Sensitivity and Reliability of Multiple Measures of Listening Effort. Ear & Hearing Publish Ah: 1–10. https://doi.org/10.1097/AUD.0000000000000950. https://journals.lww.com/10.1097/AUD.0000000000000950. · DOI
  13. 10.1177/2331216520967850 · DOI
  14. 10.1080/14992027.2018.1432901 · DOI
  15. 10.1044/2015_AJA-14-0058 · DOI
  16. 10.1016/S0079-6123(03)45011-5 · DOI · Paper page
  17. Kahneman D. (1973). Attention and effort . Citesser. ISBN 0-13-050518-8. https://doi.org/10.1.1.398.5285. https://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.398.5285.
  18. 10.1155/2012/865731 · DOI · Paper page
  19. 10.1371/journal.pone.0203629 · DOI · Paper page
  20. 10.1111/psyp.12242 · DOI
  21. 10.1080/0361073X.2016.1108712 · DOI
  22. 10.1016/j.neuron.2012.09.012 · DOI · Paper page
  23. Loewenfeld I. E., 1993, The pupil: Anatomy, physiology, and clinical applications, 2
  24. MATLAB, 2018, 9.7.0.1190202 (R2019b)
  25. 10.1093/acrefore/9780190264086.013.276 · DOI
  26. 10.1121/1.4943787 · DOI
  27. 10.1016/j.jml.2007.11.006 · DOI · Paper page
  28. 10.3109/14992027.2010.524254 · DOI
  29. 10.3758/s13428-018-1134-4 · DOI
  30. 10.1044/2018_JSLHR-H-17-0257 · DOI · Paper page
  31. 10.1037/a0014802 · DOI · Paper page
  32. 10.1177/2331216518816603 · DOI
  33. Wang Y., 2016, PLoS ONE, 11, 1
  34. 10.1097/AUD.0000000000000454 · DOI · Paper page
  35. 10.1016/j.heares.2018.05.006 · DOI · Paper page
  36. 10.1016/j.biopsycho.2018.01.010 · DOI
  37. 10.1093/sleep/11.6.562 · DOI · Paper page

Cited by

See all 28

Metadata

Authors
Neagu, M.-B., Kressner, A. A., Relaño-Iborra, H., Bækgaard, P., Dau, T., & Wendt, D.
Affiliations
  • Department of Health Technology, DTU Hearing Systems, Denmark
  • Department of Applied Mathematics and Computer Science, DTU Cognitive systems, Denmark
Venue
Trends in Hearing
Published
2023-01
Volume
27
ISSN
2331-2165
Cited by
28
References
24
Language
en
Funders
William Demant Foundation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.