X-ray microtomography of materials
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
X-ray microtomography allows imaging of the interior microstructure of materials non- destructively and with spatial resolution which can approach that of optical microscopy (typically, no better than 1 μm in samples whose cross-sectional diameter is on the order of 1 mm, and 10 &µm for 10 mm specimens). First, X-ray microtomography's origin in medical imaging and the physics behind computed tomography are reviewed. Summaries of apparatus, radiation sources, data collection schemes, and of materials applications follow. To date, most materials applications fall into one of four areas: inorganic matrix composites, transport in porous media, calcified tissue, and fatigue crack closure. Details of studies in each area highlight the advantages X-ray microtomography brings, and the final section focuses on future directions suggested by recent work using imaging modalities other than X-ray attenuation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cullity, B. D., & Weymouth, J. W. (1957) · American Journal of Physics · doi:10.1119/1.1934486 · Cited by 17,935
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
Representation of a Function by Its Line Integrals, with Some Radiological Applications
Cormack, A. M. (1963) · Journal of Applied Physics · doi:10.1063/1.1729798 · Cited by 1,399
The direct examination of three-dimensional bone architecture in vitro by computed tomography
Feldkamp, L. A., Goldstein, S. A., Parfitt, M. A., Jesion, G., & Kleerekoper, M. (1989) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650040103 · Cited by 1,071
The relationship between the structural and orthogonal compressive properties of trabecular bone
Goulet, R. W., Goldstein, S. A., Ciarelli, M. J., Kuhn, J. L., Brown, M. B., & Feldkamp, L. A. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90014-0 · Cited by 741
Quantification of connectivity in cancellous bone, with special emphasis on 3-D reconstructions
Odgaard, A., & Gundersen, H. J. G. (1993) · Bone · doi:10.1016/8756-3282(93)90245-6 · Cited by 680
Suresh, S., Zamiski, G. F., & Ritchie, D. (1981) · Metallurgical Transactions A · doi:10.1007/bf02643688 · Cited by 581
A geometric model for fatigue crack closure induced by fracture surface roughness
Suresh, S., & Ritchie, R. O. (1982) · Metallurgical Transactions A · doi:10.1007/bf02644803 · Cited by 499
Evaluation of a microcomputed tomography system to study trabecular bone structure
Kuhn, J. L., Goldstein, S. A., Feldkamp, L. A., Goulet, R. W., & Jesion, G. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080608 · Cited by 336
X-ray computed microtomography (μCT) using synchrotron radiation (SR)
Bonse, U., & Busch, F. (1996) · Progress in Biophysics and Molecular Biology · doi:10.1016/s0079-6107(96)00011-9 · Cited by 304
Cited by
Maire, E., & Withers, P. J. (2014) · International Materials Reviews · doi:10.1179/1743280413y.0000000023 · Cited by 1,374
Withers, P. J., Bouman, C., Carmignato, S., Cnudde, V., Grimaldi, D., Hagen, C. K., Maire, E., Manley, M., Du Plessis, A., & Stock, S. R. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00015-4 · Cited by 1,079
Self-citationX-ray computed tomography of polymer composites
Garcea, S. C., Wang, Y., & Withers, P. J. (2018) · Composites Science and Technology · doi:10.1016/j.compscitech.2017.10.023 · Cited by 719
Iassonov, P., Gebrenegus, T., & Tuller, M. (2009) · Water Resources Research · doi:10.1029/2009wr008087 · Cited by 628
Using X-ray computed tomography in hydrology: systems, resolutions, and limitations
Wildenschild, D., Vaz, C. M. P., Rivers, M. L., Rikard, D., & Christensen, B. S. B. (2002) · Journal of Hydrology · doi:10.1016/s0022-1694(02)00157-9 · Cited by 528
Recent advances in X-ray microtomography applied to materials
Stock, S. R. (2008) · International Materials Reviews · doi:10.1179/174328008x277803 · Cited by 517
Self-citationIn Situ Experiments with X ray Tomography: an Attractive Tool for Experimental Mechanics
Buffiere, J. Y., Maire, E., Adrien, J., Masse, J. P., & Boller, E. (2010) · Experimental Mechanics · doi:10.1007/s11340-010-9333-7 · Cited by 500
Cracks, microcracks and fracture in polymer structures: Formation, detection, autonomic repair
Awaja, F., Zhang, S., Tripathi, M., Nikiforov, A., & Pugno, N. (2016) · Progress in Materials Science · doi:10.1016/j.pmatsci.2016.07.007 · Cited by 402
NMR cryoporometry: Principles, applications and potential
Petrov, O. V., & Furó, I. (2009) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2008.06.001 · Cited by 348
Choo, H., Sham, K.-L., Bohling, J., Ngo, A., Xiao, X., Ren, Y., Depond, P. J., Matthews, M. J., & Garlea, E. (2019) · Materials & Design · doi:10.1016/j.matdes.2018.12.006 · Cited by 333
Peth, S., Horn, R., Beckmann, F., Donath, T., Fischer, J., & Smucker, A. J. M. (2008) · Soil Science Society of America Journal · doi:10.2136/sssaj2007.0130 · Cited by 316
Sinha, P. K., Halleck, P., & Wang, C. Y. (2006) · Electrochemical and Solid-State Letters · doi:10.1149/1.2203307 · Cited by 244
The imaging of failure in structural materials by synchrotron radiation X-ray microtomography
Wu, S. C., Xiao, T. Q., & Withers, P. J. (2017) · Engineering Fracture Mechanics · doi:10.1016/j.engfracmech.2017.07.027 · Cited by 225
Scharf, J., Chouchane, M., Finegan, D. P., Lu, B., Redquest, C., Kim, M.-C., Yao, W., Franco, A. A., Gostovic, D., Liu, Z., et al. (2022) · Nature Nanotechnology · doi:10.1038/s41565-022-01081-9 · Cited by 219
Evolution of fracture permeability through fluid–rock reaction under hydrothermal conditions
YASUHARA, H., POLAK, A., MITANI, Y., GRADER, A., HALLECK, P., & ELSWORTH, D. (2006) · Earth and Planetary Science Letters · doi:10.1016/j.epsl.2006.01.046 · Cited by 197
“A more detailed description on the capability and limitations of X-ray CT in core analysis may be found in Stock [34], Ketcham and Carlson [35], and Wildenschild et al. [36].”
BackgroundIn-vitro tomography and non-destructive imaging at depth of pharmaceutical solid dosage forms
ZEITLER, J., & GLADDEN, L. (2009) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2008.08.012 · Cited by 177
Fatigue and Damage in Structural Materials Studied by X-Ray Tomography
Withers, P. J., & Preuss, M. (2012) · Annual Review of Materials Research · doi:10.1146/annurev-matsci-070511-155111 · Cited by 171
Metadata
- Authors
- Stock, S. R.
- Venue
- International Materials Reviews
- Publisher
- SAGE Publications
- Published
- 1999-04
- Volume
- 44
- Issue
- 4
- Pages
- 141-164
- ISSN
- 0950-6608 (ISSN-L)
- 1743-2804
- OpenAlex
- W2065433592
- Cited by
- 366
- References
- 23
- FWCI
- 4.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.