Recent advances in X-ray microtomography applied to materials
The DOI matches its Crossref record; 162 of the 162 references it cites were found in a registry or an index.
Abstract
This review highlights recent advances in X-ray microcomputed tomography (microCT) as applied to materials, specifically advances made since the first materials microCT review appeared in International Materials Reviews . Improvements in instrumentation are covered, and one focus is microCT using phase (as opposed to absorption) contrast. Instead of grouping studies by disciplines, the reviewed reports are organised by type of application, specifically the study of the spatial distribution of phases, of cellular solids (including static and temporally evolving structures, fibrous network solids, mineralised tissues and biomedical applications), of channel structures, of deformation, fatigue and fracture, of processing and of corrosion and environmental interactions. Metrology applications are covered briefly, and several applications where microCT is combined with position resolved X-ray scattering are described in more detail. The accuracy of microCT reconstructions is discussed before data handling challenges are outlined. The review closes with speculations on the future directions of materials microCT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cellular solids structure and properties
Gibson, L. J., Ashby, M. F., et al. (1997) · Cited by 9,172
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
Caselles, V., Kimmel, R., & Sapiro, G. (1997) · International Journal of Computer Vision · doi:10.1023/a:1007979827043 · Cited by 5,244
Solso, R., & Chase, W. G. (1974) · The American Journal of Psychology · doi:10.2307/1421395 · Cited by 2,124
Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources
Pfeiffer, F., Weitkamp, T., Bunk, O., & David, C. (2006) · Nature Physics · doi:10.1038/nphys265 · Cited by 1,855
A new method for the model‐independent assessment of thickness in three‐dimensional images
Hildebrand, T., & Rüegsegger, P. (1997) · Journal of Microscopy · doi:10.1046/j.1365-2818.1997.1340694.x · Cited by 1,818
Snigirev, A., Snigireva, I., Kohn, V., Kuznetsov, S., & Schelokov, I. (1995) · Review of Scientific Instruments · doi:10.1063/1.1146073 · Cited by 1,493
(2001) · CRC Press eBooks · doi:10.1201/b14263 · Cited by 1,451
Hildebrand, T., Laib, A., Müller, R., Dequeker, J., & Rüegsegger, P. (1999) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1999.14.7.1167 · Cited by 1,303
X-ray phase imaging with a grating interferometer
Weitkamp, T., Diaz, A., David, C., Pfeiffer, F., Stampanoni, M., Cloetens, P., & Ziegler, E. (2005) · Optics Express · doi:10.1364/opex.13.006296 · Cited by 1,211
Cited by
Maire, E., & Withers, P. J. (2014) · International Materials Reviews · doi:10.1179/1743280413y.0000000023 · Cited by 1,374
In-operando high-speed tomography of lithium-ion batteries during thermal runaway
Finegan, D. P., Scheel, M., Robinson, J. B., Tjaden, B., Hunt, I., Mason, T. J., Millichamp, J., Di Michiel, M., Offer, G. J., Hinds, G., et al. (2015) · Nature Communications · doi:10.1038/ncomms7924 · Cited by 844
X-ray computed tomography of polymer composites
Garcea, S. C., Wang, Y., & Withers, P. J. (2018) · Composites Science and Technology · doi:10.1016/j.compscitech.2017.10.023 · Cited by 719
Landis, E. N., & Keane, D. T. (2010) · Materials Characterization · doi:10.1016/j.matchar.2010.09.012 · Cited by 608
Tammas-Williams, S., Zhao, H., Léonard, F., Derguti, F., Todd, I., & Prangnell, P. B. (2015) · Materials Characterization · doi:10.1016/j.matchar.2015.02.008 · Cited by 590
X-ray microtomography shows pore structure and tortuosity in alkali-activated binders
Provis, J. L., Myers, R. J., White, C. E., Rose, V., & van Deventer, J. S. J. (2012) · Cement and Concrete Research · doi:10.1016/j.cemconres.2012.03.004 · Cited by 572
An overview of tailoring strain delocalization for strength-ductility synergy
Wu, H., & Fan, G. (2020) · Progress in Materials Science · doi:10.1016/j.pmatsci.2020.100675 · Cited by 536
In Situ Experiments with X ray Tomography: an Attractive Tool for Experimental Mechanics
Buffiere, J. Y., Maire, E., Adrien, J., Masse, J. P., & Boller, E. (2010) · Experimental Mechanics · doi:10.1007/s11340-010-9333-7 · Cited by 500
Defects and anomalies in powder bed fusion metal additive manufacturing
Mostafaei, A., Zhao, C., He, Y., Reza Ghiaasiaan, S., Shi, B., Shao, S., Shamsaei, N., Wu, Z., Kouraytem, N., Sun, T., et al. (2022) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2021.100974 · Cited by 491
Developing X-ray Computed Tomography to non-invasively image 3-D root systems architecture in soil
Mooney, S. J., Pridmore, T. P., Helliwell, J., & Bennett, M. J. (2012) · Plant and Soil · doi:10.1007/s11104-011-1039-9 · Cited by 454
An investigation of single sand particle fracture using X-ray micro-tomography
Zhao, B., Wang, J., Coop, M. R., Viggiani, G., & JIANG, M. (2015) · Géotechnique · doi:10.1680/geot.4.p.157 · Cited by 360
Bale, H. A., Haboub, A., MacDowell, A. A., Nasiatka, J. R., Parkinson, D. Y., Cox, B. N., Marshall, D. B., & Ritchie, R. O. (2013) · Nature Materials · doi:10.1038/nmat3497 · Cited by 335
Choo, H., Sham, K.-L., Bohling, J., Ngo, A., Xiao, X., Ren, Y., Depond, P. J., Matthews, M. J., & Garlea, E. (2019) · Materials & Design · doi:10.1016/j.matdes.2018.12.006 · Cited by 333
Finegan, D. P., Darcy, E., Keyser, M., Tjaden, B., Heenan, T. M. M., Jervis, R., Bailey, J. J., Malik, R., Vo, N. T., Magdysyuk, O. V., et al. (2017) · Energy & Environmental Science · doi:10.1039/c7ee00385d · Cited by 326
Maskery, I., Aboulkhair, N. T., Corfield, M. R., Tuck, C., Clare, A. T., Leach, R. K., Wildman, R. D., Ashcroft, I. A., & Hague, R. J. M. (2016) · Materials Characterization · doi:10.1016/j.matchar.2015.12.001 · Cited by 317
Digital Volume Correlation: Review of Progress and Challenges
Buljac, A., Jailin, C., Mendoza, A., Neggers, J., Taillandier-Thomas, T., Bouterf, A., Smaniotto, B., Hild, F., & Roux, S. (2018) · Experimental Mechanics · doi:10.1007/s11340-018-0390-7 · Cited by 305
Tortuosity in electrochemical devices: a review of calculation approaches
Tjaden, B., Brett, D. J. L., & Shearing, P. R. (2018) · International Materials Reviews · doi:10.1080/09506608.2016.1249995 · Cited by 278
Tammas-Williams, S., Withers, P. J., Todd, I., & Prangnell, P. B. (2016) · Metallurgical and Materials Transactions A · doi:10.1007/s11661-016-3429-3 · Cited by 269
X-Ray Tomography for Lithium Ion Battery Research: A Practical Guide
Pietsch, P., & Wood, V. (2017) · Annual Review of Materials Research · doi:10.1146/annurev-matsci-070616-123957 · Cited by 255
Helliwell, J. R., Sturrock, C. J., Grayling, K. M., Tracy, S. R., Flavel, R. J., Young, I. M., Whalley, W. R., & Mooney, S. J. (2013) · European Journal of Soil Science · doi:10.1111/ejss.12028 · Cited by 225
The imaging of failure in structural materials by synchrotron radiation X-ray microtomography
Wu, S. C., Xiao, T. Q., & Withers, P. J. (2017) · Engineering Fracture Mechanics · doi:10.1016/j.engfracmech.2017.07.027 · Cited by 225
Imaging Catalysts at Work: A Hierarchical Approach from the Macro‐ to the Meso‐ and Nano‐scale
Grunwaldt, J., Wagner, J. B., & Dunin‐Borkowski, R. E. (2013) · ChemCatChem · doi:10.1002/cctc.201200356 · Cited by 164
Voxel-Scale Digital Volume Correlation
Leclerc, H., Périé, J.-N., Roux, S., & Hild, F. (2011) · Experimental Mechanics · doi:10.1007/s11340-010-9407-6 · Cited by 161
Metadata
- Authors
- Stock, S. R.
- Venue
- International Materials Reviews
- Publisher
- SAGE Publications
- Published
- 2008-05
- Volume
- 53
- Issue
- 3
- Pages
- 129-181
- ISSN
- 0950-6608 (ISSN-L)
- 1743-2804
- OpenAlex
- W2021674156
- Cited by
- 517
- References
- 162
- FWCI
- 24.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.