Investigation into depth dependence of effect of E-beam radiation on mechanical and degradation properties of polylactide
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
The aim of the present study was to determine whether electron beam (E-beam) radiation has any depth dependent effect on the mechanical and degradation properties of a typical degradable polymer used for medical applications. Any such effect could be utilised to tailor the properties of degradable polymers for a specific application. The material investigated in the present study is a form of polylactide (PLA). Thin layers of the material were compression moulded and arranged at various depths within a framework, with acrylic spacers separating them. The samples were then dosed with 40 kGy of E-beam radiation. Following irradiation the samples were subjected to accelerated aging through hydrolytic degradation in phosphate buffer solution at 70°C. Gel permeation chromatography testing showed that samples within a certain distance of the irradiated surface had consistently lower molecular weight than deeper samples throughout degradation. Corresponding to this, the shallower samples also had lower tensile and flexural strengths than the deeper samples, though no significant variation in modulus was recorded. The results of this study indicate that E-beam radiation can produce a depth dependant variation in mechanical and degradation properties of PLA. The potential therefore exists to modify the through thickness properties of a degradable polymer in such a way as to improve its suitability for a specific medical application.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The molecular weight of PLG, which is known as a candidate material for SMP synthesis, decreases after g-irradiation, and this degradation process continues on storage for 4 weeks [57,58,61].”
From Shape-memory polymers as a technology platform for biomedical applications (2010) · cites this paper as [61]
In the citing paper
“In addition, e-beam sterilization (50-200 kGy) is described to alter the degradation properties of PLG [57,61].”
From Shape-memory polymers as a technology platform for biomedical applications (2010) · cites this paper as [61]
Citations
Cites
Synthetic biodegradable polymers as orthopedic devices
Middleton, J. C., & Tipton, A. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00101-0 · Cited by 2,741
Mechanisms of polymer degradation and erosion
Göpferich, A. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85755-3 · Cited by 1,781
Late degradation tissue response to poly(?-lactide) bone plates and screws
Bergsma, J. (1995) · Biomaterials · doi:10.1016/0142-9612(95)91092-d · Cited by 799
Li, S. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(1999)48:3<246::aid-jbm7>3.0.co;2-x · Cited by 671
Li, S. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(1999)48:3<342::aid-jbm20>3.0.co;2-7 · Cited by 664
High-energy radiation and polymers: A review of commercial processes and emerging applications
Clough, R. L. (2001) · Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms · doi:10.1016/s0168-583x(01)00966-1 · Cited by 627
Loo, J. S. C., Ooi, C. P., & Boey, F. Y. C. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.05.001 · Cited by 277
Göpferich, A. (1997) · Macromolecules · doi:10.1021/ma961627y · Cited by 245
Optimizing the sterilization of PLGA scaffolds for use in tissue engineering
Holy, C. E., Cheng, C., Davies, J. E., & Shoichet, M. S. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00136-8 · Cited by 223
Schliecker, G., Schmidt, C., Fuchs, S., & Kissel, T. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00243-6 · Cited by 208
Degradation of poly-L-lactide. Part 2: increased temperature accelerated degradation
Weir, N. A., Buchanan, F. J., Orr, J. F., Farrar, D. F., & Dickson, G. R. (2004) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411041932809 · Cited by 171
Self-citationProcessing, annealing and sterilisation of poly-l-lactide
Weir, N. A., Buchanan, F. J., Orr, J. F., Farrar, D. F., & Boyd, A. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.10.076 · Cited by 160
Self-citationDegradation of polydispersed poly(l-lactic acid) to modulate lactic acid release
von Recum, H. A., Cleek, R. L., Eskin, S. G., & Mikos, A. G. (1995) · Biomaterials · doi:10.1016/0142-9612(95)98816-w · Cited by 133
Comparison of electron beam irradiation with gamma processing for medical packaging materials
Woo, L., & Sandford, C. (2002) · Radiation Physics and Chemistry · doi:10.1016/s0969-806x(01)00664-8 · Cited by 88
Nuutinen, J., Clerc, C. O., Virta, T., & Törmälä, P. (2002) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/15685620260449723 · Cited by 64
MONTANARI, L., Cilurzo, F., Selmin, F., Conti, B., Genta, I., Poletti, G., Orsini, F., & Valvo, L. (2003) · Journal of Controlled Release · doi:10.1016/s0168-3659(03)00153-6 · Cited by 63
Cytotoxicity of poly(96l/4d-lactide): the influence of degradation and sterilization
Cordewener, F. W., van Geffen, M. F., Joziasse, C. A. P., Schmitz, J. P., Bos, R. R. M., Rozema, F. R., & Pennings, A. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00111-3 · Cited by 63
Bergsma, J., Joziasse, C. A. P., Bos, R. R. M., & Pennings, A. J. (1996) · Biomaterials · doi:10.1016/s0142-9612(96)90012-5 · Cited by 1
Research works printed but not linked: 1
- Dailey L. A., 2005, Drug Discovery Today: TechnoL
Cited by
Shape-memory polymers as a technology platform for biomedical applications
Lendlein, A., Behl, M., Hiebl, B., & Wischke, C. (2010) · Expert Review of Medical Devices · doi:10.1586/erd.10.8 · Cited by 469
Sterilization techniques for biodegradable scaffolds in tissue engineering applications
Dai, Z., Ronholm, J., Tian, Y., Sethi, B., & Cao, X. (2016) · Journal of Tissue Engineering · doi:10.1177/2041731416648810 · Cited by 355
Shape-Memory Polymers for Biomedical Applications
Yakacki, C. M., & Gall, K. (2009) · Advances in polymer science · doi:10.1007/12_2009_23 · Cited by 168
Yakacki, C. M., Lyons, M. B., Rech, B., Gall, K., & Shandas, R. (2008) · Biomedical Materials · doi:10.1088/1748-6041/3/1/015010 · Cited by 50
“Leonard et al [15] and Loo et al [16] studied the effects of e-beam radiation on poly(lactide) and PLG to develop relationships to tailor degradation properties of the polymers with respect to dose.”
BackgroundSpectroscopy techniques for analyzing the hydrolysis of PLGA and PLLA
Tan, H. Y., Widjaja, E., Boey, F., & Loo, S. C. J. (2009) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31419 · Cited by 52
Metadata
- Authors
- Leonard, D., Buchanan, F., & Farrar, D.
- Venue
- Plastics, Rubber and Composites
- Publisher
- SAGE Publications
- Published
- 2006-10
- Volume
- 35
- Issue
- 8
- Pages
- 303-309
- ISSN
- 0959-8111 (ISSN-L)
- 1465-8011
- 1743-2898
- OpenAlex
- W2004817094
- Cited by
- 13
- References
- 17
- Citations by year
- 2024: 1 · 2022: 1 · 2019: 2 · 2017: 2 · 2016: 1 · 2013: 2
- FWCI
- 0.55
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Plastics Rubber and Composites Macromolecular Engineering (publishedVersion)
- Research Portal (Queen's University Belfast) (submittedVersion)
- Topics
- Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
- Physical Sciences › Materials Science › Polymers and Plastics › Polymer Nanocomposite Synthesis and Irradiation
- Physical Sciences › Materials Science › Polymers and Plastics › Polymer crystallization and properties
- Keywords
- polylactic acid, electron irradiation, depth dependence, hydrolytic degradation, accelerated aging, molecular weight reduction, tensile strength, flexural strength, mechanical properties, degradable polymers, biomedical polymers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.