Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 274

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Shear stress affects the intracellular distribution of eNOS: direct demonstration by a novel in vivo technique

Open access
Cheng, Caroline, van Haperen, Rien, de Waard, Monique, van Damme, Luc C. A., Tempel, Dennie, Hanemaaijer, Laurens, van Cappellen, Gert W. A., Bos, Joop, Slager, Cornelis J., Duncker, Dirk J., van der Steen, Anton F. W., de Crom, Rini, Krams, Rob · 2005 · Blood

Abstract

The focal location of atherosclerosis in the vascular tree is correlated with local variations in shear stress. We developed a method to induce defined variations in shear stress in a straight vessel segment of a mouse. To this end, a cylinder with a tapered lumen was placed around the carotid artery, inducing a high shear stress field. Concomitantly, regions of low shear stress and oscillatory shear stress were created upstream and down-stream of the device, respectively. This device was used in mice transgenic for an eNOS3GFP fusion gene. We observed a strong induction of endothelial nitric oxide synthase–green fluorescent protein (eNOS-GFP) mRNA expression in the high shear stress region compared with the other regions (P < .05). Quantification of eNOS-GFP fluorescence or of immunoreactivity to the Golgi complex or to platelet endothelial cell adhesion molecule 1 (PECAM-1) showed an increase in the high shear stress region (P < .05) compared with nontreated carotid arteries. Colocalization of eNOS-GFP with either the Golgi complex or PECAM-1 also responded to alterations of shear stress. In conclusion, we showed a direct response of mRNA and protein expression in vivo to induced variations of shear stress. This model provides the opportunity to study the relationship between shear stress alterations, gene expression, and atherosclerosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1182/blood-2005-06-2326

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 31 references

Cited by

See all 274

Metadata

Authors
Cheng, C., van Haperen, R., de Waard, M., van Damme, L. C. A., Tempel, D., Hanemaaijer, L., van Cappellen, G. W. A., Bos, J., Slager, C. J., Duncker, D. J., van der Steen, A. F. W., de Crom, R., & Krams, R.
Venue
Blood
Published
2005-12-01
Volume
106
Issue
12
Pages
3691-3698
ISSN
  • 0006-4971 (ISSN-L)
  • 1528-0020
OpenAlex
W2127306451
Cited by
274
References
31
FWCI
9.49
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Shear stress affects the intracellular distribution of eNOS: direct demonstration by a novel in vivo technique. https://app.cochat.ai/papers/10.1182/blood-2005-06-2326
The paper
Cheng, C., van Haperen, R., de Waard, M., van Damme, L. C. A., Tempel, D., Hanemaaijer, L., van Cappellen, G. W. A., Bos, J., Slager, C. J., Duncker, D. J., van der Steen, A. F. W., de Crom, R., & Krams, R. (2005). Shear stress affects the intracellular distribution of eNOS: direct demonstration by a novel in vivo technique. Blood. https://doi.org/10.1182/blood-2005-06-2326

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.