Canine scent detection in the diagnosis of lung cancer: revisiting a puzzling phenomenon
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Patient prognosis in lung cancer largely depends on early diagnosis. The exhaled breath of patients may represent the ideal specimen for future lung cancer screening. However, the clinical applicability of current diagnostic sensor technologies based on signal pattern analysis remains incalculable due to their inability to identify a clear target. To test the robustness of the presence of a so far unknown volatile organic compound in the breath of patients with lung cancer, sniffer dogs were applied. Exhalation samples of 220 volunteers (healthy individuals, confirmed lung cancer or chronic obstructive pulmonary disease (COPD)) were presented to sniffer dogs following a rigid scientific protocol. Patient history, drug administration and clinicopathological data were analysed to identify potential bias or confounders. Lung cancer was identified with an overall sensitivity of 71% and a specificity of 93%. Lung cancer detection was independent from COPD and the presence of tobacco smoke and food odours. Logistic regression identified two drugs as potential confounders. It must be assumed that a robust and specific volatile organic compound (or pattern) is present in the breath of patients with lung cancer. Additional research efforts are required to overcome the current technical limitations of electronic sensor technologies to engineer a clinically applicable screening tool.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vestbo, J., Hurd, S. S., Agustí, A. G., Jones, P. W., Vogelmeier, C., Anzueto, A., Barnes, P. J., Fabbri, L. M., Martinez, F. J., Nishimura, M., et al. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201204-0596pp · Cited by 15,983
Rabe, K. F., Hurd, S., Anzueto, A., Barnes, P. J., Buist, S. A., Calverley, P., Fukuchi, Y., Jenkins, C., Rodriguez-Roisin, R., van Weel, C., et al. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200703-456so · Cited by 4,925
Estimates of the cancer incidence and mortality in Europe in 2006
Ferlay, J., Autier, P., Boniol, M., Heanue, M., Colombet, M., & Boyle, P. (2007) · Annals of Oncology · doi:10.1093/annonc/mdl498 · Cited by 4,036
Standardisation of the measurement of lung volumes
Wanger, J., Clausen, J. L., Coates, A., Pedersen, O. F., Brusasco, V., Burgos, F., Casaburi, R., Crapo, R., Enright, P., van der Grinten, C. P. M., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00035005 · Cited by 2,768 · cited 1×
“Body plethysmography (flow plethysmography) was performed according to established guidelines (CareFusion, Hoechberg, Germany) [12].”
MethodRabe, K. F. (2007) · American Journal of Respiratory and Critical Care Medicine · Cited by 2,567
Estimates of cancer incidence and mortality in Europe in 2008
Ferlay, J., Parkin, D. M., & Steliarova-Foucher, E. (2010) · European Journal of Cancer · doi:10.1016/j.ejca.2009.12.014 · Cited by 2,319
Analysis of discrimination mechanisms in the mammalian olfactory system using a model nose
Persaud, K., & Dodd, G. (1982) · Nature · doi:10.1038/299352a0 · Cited by 1,592 · cited 1×
“Since 1982, research was conducted to develop sensor arrays and pattern recognition technologies, commonly referred to as “electronic noses” that could detect and recognize odors and flavors [5].”
BackgroundQuantitative Analysis of Urine Vapor and Breath by Gas-Liquid Partition Chromatography
Pauling, L., Robinson, A. B., Teranishi, R., & Cary, P. (1971) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.68.10.2374 · Cited by 1,025 · cited 1×
“Since their first delineation by Pauling and coworkers in 1971, 3481 different VOCs have been described in the human breath - most of them in picomolar concentrations (10 mol/l or particles per trillion) [15, 16].”
BackgroundPeng, G., Hakim, M., Broza, Y. Y., Billan, S., Abdah-Bortnyak, R., Kuten, A., Tisch, U., & Haick, H. (2010) · British Journal of Cancer · doi:10.1038/sj.bjc.6605810 · Cited by 775 · cited 1×
“It was hypothesized that these devices may be applicable in identifying volatile organic compounds (VOCs) that are linked to cancers in their early stages and thereby making them potential non-invasive and inexpensive diagnostic tools for the medical community [6, 7].”
BackgroundVariation in volatile organic compounds in the breath of normal humans
Phillips, M., Herrera, J., Krishnan, S., Zain, M., Greenberg, J., & Cataneo, R. N. (1999) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/s0378-4347(99)00127-9 · Cited by 738 · cited 1×
“Since their first delineation by Pauling and coworkers in 1971, 3481 different VOCs have been described in the human breath - most of them in picomolar concentrations (10 mol/l or particles per trillion) [15, 16].”
Background
Cited by
Progress and prospects of early detection in lung cancer
Blandin Knight, S., Crosbie, P. A., Balata, H., Chudziak, J., Hussell, T., & Dive, C. (2017) · Open Biology · doi:10.1098/rsob.170070 · Cited by 935
Analysis of Exhaled Breath for Disease Detection
Amann, A., Miekisch, W., Schubert, J., Buszewski, B., Ligor, T., Jezierski, T., Pleil, J., & Risby, T. (2014) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071213-020043 · Cited by 214
Breath sensors for lung cancer diagnosis
Adiguzel, Y., & Kulah, H. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.10.023 · Cited by 189
Canine Olfaction: Physiology, Behavior, and Possibilities for Practical Applications
Kokocińska-Kusiak, A., Woszczyło, M., Zybala, M., Maciocha, J., Barłowska, K., & Dzięcioł, M. (2021) · Animals · doi:10.3390/ani11082463 · Cited by 159
Hackner, K., & Pleil, J. (2017) · Journal of Breath Research · doi:10.1088/1752-7163/aa5524 · Cited by 46
Metadata
- Authors
- Ehmann, R., Boedeker, E., Friedrich, U., Sagert, J., Dippon, J., Friedel, G., & Walles, T.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2011-08-18
- Volume
- 39
- Issue
- 3
- Pages
- 669-676
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2103389940
- Cited by
- 207
- References
- 25
- FWCI
- 9.48
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.