Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 303

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

The Leicester Cough Monitor: preliminary validation of an automated cough detection system in chronic cough

Birring, S. S., Fleming, T., Matos, S., Raj, A. A., Evans, D. H., Pavord, I. D. · 2008 · European Respiratory Journal

Abstract

Chronic cough is a common condition that presents to both primary and secondary care. Assessment and management are hampered by the absence of well-validated outcome measures. The present study comprises the validation of the Leicester Cough Monitor (LCM), an automated sound-based ambulatory cough monitor. Cough frequency was measured with the LCM and compared with coughs and other sounds counted manually over 2 h of a 6-h recording by two observers in nine patients with chronic cough in order to determine the sensitivity and specificity of the LCM. Automated cough frequency was also compared with manual counts from one observer in 15 patients with chronic cough and eight healthy subjects. All subjects underwent 6-h recordings. A subgroup consisting of six control and five patients with stable chronic cough underwent repeat automated measurements ≥3 months apart. A further 50 patients with chronic cough underwent 24-h automated cough monitoring. The LCM had a sensitivity and specificity of 91 and 99%, respectively, for detecting cough and a false-positive rate of 2.5 events·h−1. Mean±sem automated cough counts·patient·h−1 was 48±9 in patients with chronic cough and 2±1 in the control group (mean difference 46 counts·patient·h−1; 95% confidence interval (CI) 20–71). The automated cough counts were repeatable (intra-subject sd 11.4 coughs·patient·h−1; intra-class correlation coefficient 0.9). The cough frequency in patients undergoing 24-h automated monitoring was 19 coughs·patient·h−1; daytime (08:00–22:00 h) cough frequency was significantly greater than overnight cough frequency (25 versus 10 coughs·patient·h−1; mean difference 15 coughs·patient·h−1, 95% CI 8–22). The Leicester Cough Monitor is a valid and reliable tool that can be used to assess 24-h cough frequency in patients with cough. It should be a useful tool to assess patients with cough in clinical trials and longitudinal studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1183/09031936.00057407

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 303

Metadata

Authors
Birring, S. S., Fleming, T., Matos, S., Raj, A. A., Evans, D. H., & Pavord, I. D.
Venue
European Respiratory Journal
Published
2008-01-09
Volume
31
Issue
5
Pages
1013-1018
ISSN
  • 0903-1936 (ISSN-L)
  • 1399-3003
OpenAlex
W2119036316
Cited by
303
References
14
FWCI
8.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Leicester Cough Monitor: preliminary validation of an automated cough detection system in chronic cough. https://app.cochat.ai/papers/10.1183/09031936.00057407
The paper
Birring, S. S., Fleming, T., Matos, S., Raj, A. A., Evans, D. H., & Pavord, I. D. (2008). The Leicester Cough Monitor: preliminary validation of an automated cough detection system in chronic cough. European Respiratory Journal. https://doi.org/10.1183/09031936.00057407

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.