The Leicester Cough Monitor: preliminary validation of an automated cough detection system in chronic cough
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Chronic cough is a common condition that presents to both primary and secondary care. Assessment and management are hampered by the absence of well-validated outcome measures. The present study comprises the validation of the Leicester Cough Monitor (LCM), an automated sound-based ambulatory cough monitor. Cough frequency was measured with the LCM and compared with coughs and other sounds counted manually over 2 h of a 6-h recording by two observers in nine patients with chronic cough in order to determine the sensitivity and specificity of the LCM. Automated cough frequency was also compared with manual counts from one observer in 15 patients with chronic cough and eight healthy subjects. All subjects underwent 6-h recordings. A subgroup consisting of six control and five patients with stable chronic cough underwent repeat automated measurements ≥3 months apart. A further 50 patients with chronic cough underwent 24-h automated cough monitoring. The LCM had a sensitivity and specificity of 91 and 99%, respectively, for detecting cough and a false-positive rate of 2.5 events·h−1. Mean±sem automated cough counts·patient·h−1 was 48±9 in patients with chronic cough and 2±1 in the control group (mean difference 46 counts·patient·h−1; 95% confidence interval (CI) 20–71). The automated cough counts were repeatable (intra-subject sd 11.4 coughs·patient·h−1; intra-class correlation coefficient 0.9). The cough frequency in patients undergoing 24-h automated monitoring was 19 coughs·patient·h−1; daytime (08:00–22:00 h) cough frequency was significantly greater than overnight cough frequency (25 versus 10 coughs·patient·h−1; mean difference 15 coughs·patient·h−1, 95% CI 8–22). The Leicester Cough Monitor is a valid and reliable tool that can be used to assess 24-h cough frequency in patients with cough. It should be a useful tool to assess patients with cough in clinical trials and longitudinal studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Birring, S. S. (2003) · Thorax · doi:10.1136/thorax.58.4.339 · Cited by 1,062
Self-citationThe diagnosis and management of chronic cough
Morice, A. H., & committee members (2004) · European Respiratory Journal · doi:10.1183/09031936.04.00027804 · Cited by 518
The Diagnosis and Treatment of Cough
Irwin, R. S., & Madison, J. M. (2000) · New England Journal of Medicine · doi:10.1056/nejm200012073432308 · Cited by 485
Eosinophilic Bronchitis Is an Important Cause of Chronic Cough
BRIGHTLING, C. E., WARD, R., GOH, K. L., WARDLAW, A. J., & PAVORD, I. D. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.160.2.9810100 · Cited by 431
Self-citationCoughing frequency in patients with persistent cough: assessment using a 24 hour ambulatory recorder
Hsu, J., Stone, R., Logan-Sinclair, R., Worsdell, M., Busst, C., & Chung, K. (1994) · European Respiratory Journal · doi:10.1183/09031936.94.07071246 · Cited by 342
Detection of Cough Signals in Continuous Audio Recordings Using Hidden Markov Models
Matos, S., Birring, S. S., Pavord, I. D., & Evans, D. H. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.873548 · Cited by 216
Self-citationCough frequency, cough sensitivity and health status in patients with chronic cough
Birring, S. S., Matos, S., Patel, R. B., Prudon, B., Evans, D. H., & Pavord, I. D. (2006) · Respiratory Medicine · doi:10.1016/j.rmed.2005.09.023 · Cited by 166
Self-citationCough and Glottic-Stop Reflex Sensitivity in Health and Disease
Prudon, B., Birring, S. S., Vara, D. D., Hall, A. P., Thompson, J. P., & Pavord, I. D. (2005) · CHEST Journal · doi:10.1378/chest.127.2.550 · Cited by 139
Self-citationPavesi, L. A., Subburaj, S., & Porter-Shaw, K. (2001) · CHEST Journal · doi:10.1378/chest.120.4.1121 · Cited by 137
Coyle, M., Keenan, D. B., Henderson, L. S., Watkins, M. L., Haumann, B., Mayleben, D. W., & Wilson, M. G. (2005) · Cough · doi:10.1186/1745-9974-1-3 · Cited by 121
Cited by
Gabapentin for refractory chronic cough: a randomised, double-blind, placebo-controlled trial
Ryan, N. M., Birring, S. S., & Gibson, P. G. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60776-4 · Cited by 506
Self-citationGrunewald, J., Grutters, J. C., Arkema, E. V., Saketkoo, L. A., Moller, D. R., & Müller-Quernheim, J. (2019) · Nature Reviews Disease Primers · doi:10.1038/s41572-019-0096-x · Cited by 479
Pregabalin and Speech Pathology Combination Therapy for Refractory Chronic Cough
Vertigan, A. E., Kapela, S. L., Ryan, N. M., Birring, S. S., McElduff, P., & Gibson, P. G. (2016) · Chest · doi:10.1378/chest.15-1271 · Cited by 281
Self-citationAccurate and privacy preserving cough sensing using a low-cost microphone
Larson, E. C., Lee, T., Liu, S., Rosenfeld, M., & Patel, S. N. (2011) · Proceedings of the 13th international conference on Ubiquitous computing · doi:10.1145/2030112.2030163 · Cited by 217
“Challenges with Existing Cough Sensing Approaches Researchers have recently created systems that use machine learning to automatically detect coughs from recorded audio streams [2, 4, 13, 26, 27].”
BackgroundInfluentialAntitussive Drugs—Past, Present, and Future
Dicpinigaitis, P. V., Morice, A. H., Birring, S. S., McGarvey, L., Smith, J. A., Canning, B. J., & Page, C. P. (2014) · Pharmacological Reviews · doi:10.1124/pr.111.005116 · Cited by 194
“K+ ATPase is of interest (Carfagna and Muhoberac, 1993).”
BackgroundSelf-citationChamberlain Mitchell, S. A. F., Garrod, R., Clark, L., Douiri, A., Parker, S. M., Ellis, J., Fowler, S. J., Ludlow, S., Hull, J. H., Chung, K. F., et al. (2017) · Thorax · doi:10.1136/thoraxjnl-2016-208843 · Cited by 194
Self-citationCough and the Transmission of Tuberculosis
Turner, R. D., & Bothamley, G. H. (2015) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiu625 · Cited by 158
“Several methods for recording cough activity have been used, but the cough monitors involved in most published studies in this area are based on ambulatory recordings of cough sounds [37, 38].”
BackgroundMethodWilliams, C. M., Abdulwhhab, M., Birring, S. S., De Kock, E., Garton, N. J., Townsend, E., Pareek, M., Al-Taie, A., Pan, J., Ganatra, R., et al. (2020) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(19)30707-8 · Cited by 142
Self-citationHome monitoring in interstitial lung diseases
Wijsenbeek, M. S., Moor, C. C., Johannson, K. A., Jackson, P. D., Khor, Y. H., Kondoh, Y., Rajan, S. K., Tabaj, G. C., Varela, B. E., van der Wal, P., et al. (2023) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(22)00228-4 · Cited by 98
Inhaled pirfenidone solution (AP01) for IPF: a randomised, open-label, dose–response trial
West, A., Chaudhuri, N., Barczyk, A., Wilsher, M. L., Hopkins, P., Glaspole, I., Corte, T. J., Šterclová, M., Veale, A., Jassem, E., et al. (2023) · Thorax · doi:10.1136/thorax-2022-219391 · Cited by 67
Xu, X., Nemati, E., Vatanparvar, K., Nathan, V., Ahmed, T., Rahman, M. M., McCaffrey, D., Kuang, J., & Gao, J. A. (2021) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3448124 · Cited by 38
“Researchers have proposed a large number of algorithms for automatic cough detection, such as support vector machine (SVM) [30], hidden Markov models (HMM) [14], random forest (RF) [50], k-nearest neighbor (kNN) [59], Gaussian mixture models (GMM) [54], time delay neural network (TDNN) [8], convolutional neural networ…”
BackgroundRhee, H., Belyea, M. J., Sterling, M., & Bocko, M. F. (2015) · Journal of Medical Internet Research · doi:10.2196/jmir.4975 · Cited by 30
“5 events/hour by the Leicester Cough Monitor [54].”
Influential
Metadata
- Authors
- Birring, S. S., Fleming, T., Matos, S., Raj, A. A., Evans, D. H., & Pavord, I. D.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2008-01-09
- Volume
- 31
- Issue
- 5
- Pages
- 1013-1018
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2119036316
- Cited by
- 303
- References
- 14
- FWCI
- 8.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.