Influence of setting on unattended respiratory monitoring in the sleep apnoea/hypopnoea syndrome
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The high demand for full polysomnography and the better quality of sleep at home are the main reasons for performing home sleep studies. Home respiratory monitoring has been evaluated in several studies, but the influence of setting on the results of unattended respiratory monitoring has not been assessed to date. Unattended monitoring of respiratory variables at home and in the sleep laboratory was conducted in 35 consecutive patients with suspected sleep apnoea/hypopnoea syndrome. Respiratory variables during sleep, rate of successful studies and patient preference were compared. The data acquisition failure rate was 2.8% in the sleep laboratory and 5.7% at home. The mean difference between apnoea/hypopnoea indices (AHI) obtained from home and laboratory studies was −0.21±8 (95% confidence interval 3.27–2.84). Using the method comparison approach of Bland and Altman, the limits of agreement of the mean difference between AHI home and AHI laboratory were −16.7 and 17.1. No difference was observed between the studies in time spent in different body positions. When patients were asked where they would prefer to repeat the sleep study, 53% replied at home, 28% in hospital and 19% showed no preference. It was concluded that the setting of unattended respiratory monitoring (home or sleep laboratory) influences neither the number of valid studies nor the results of the respiratory parameters measured; most patients, however, preferred home studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Collop, N. A., Anderson, W. M., Boehlecke, B., Claman, D., Goldberg, R., Gottlieb, D. J., Hudgel, D., Sateia, M., Schwab, R., & Portable Monitoring Task Force of the American Academy of Sleep Medicine (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27032 · Cited by 1,550
Validation of Watch-PAT-200 Against Polysomnography During Pregnancy
O’Brien, L. M., Bullough, A. S., Shelgikar, A. V., Chames, M. C., Armitage, R., & Chervin, R. D. (2012) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.1916 · Cited by 133
“39 Pregnant women often have other young children at home, and in addition do not look forward to the discomfort of a night in these subjects often are not referred to sleep laboratories.”
Respiratory Polygraphy With Actigraphy in the Diagnosis of Sleep Apnea-Hypopnea Syndrome
García-Díaz, E., Quintana-Gallego, E., Ruiz, A., Carmona-Bernal, C., Sánchez-Armengol, Á., Botebol-Benhamou, G., & Capote, F. (2007) · Chest · doi:10.1378/chest.06-1604 · Cited by 80
Effect of an ambulatory diagnostic and treatment programme in patients with sleep apnoea
Andreu, A. L., Chiner, E., Sancho-Chust, J. N., Pastor, E., Llombart, M., Gomez-Merino, E., Senent, C., & Barbé, F. (2012) · European Respiratory Journal · doi:10.1183/09031936.00013311 · Cited by 62
Metadata
- Authors
- Lloberes, P., Sampol, G., Levy, G., Aristizabal, D., Sagales, T., De la Calzada, M., Roca, A., Cañas, I., & Morell, F.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2001-09
- Volume
- 18
- Issue
- 3
- Pages
- 530-534
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2050929443
- Cited by
- 30
- References
- 2
- FWCI
- 0.55
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Influence of setting on unattended respiratory monitoring in the sleep apnoea/hypopnoea syndrome. https://app.cochat.ai/papers/10.1183/09031936.01.00072401
- The paper
- Lloberes, P., Sampol, G., Levy, G., Aristizabal, D., Sagales, T., De la Calzada, M., Roca, A., Cañas, I., & Morell, F. (2001). Influence of setting on unattended respiratory monitoring in the sleep apnoea/hypopnoea syndrome. European Respiratory Journal. https://doi.org/10.1183/09031936.01.00072401
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.