CoChat

Physiology and pathophysiology of pleural fluid turnover

Open access
Zocchi, L. · 2002 · European Respiratory Journal
Cited by 209

The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.

Abstract

Tight control of the volume and composition of the pleural liquid is necessary to ensure an efficient mechanical coupling between lung and chest wall. Liquid enters the pleural space through the parietal pleura down a net filtering pressure gradient. Liquid removal is provided by an absorptive pressure gradient through the visceral pleura, by lymphatic drainage through the stomas of the parietal pleura, and by cellular mechanisms. Indeed, contrary to what was believed in the past, pleural mesothelial cells are metabolically active, and possess the cellular features for active transport of solutes, including vesicular transport of protein. Furthermore, the mesothelium was shown, on the basis of recent experimental evidence, both in vivo and in vitro, to be a less permeable barrier than previously believed, being provided with permeability characteristics similar to those of the microvascular endothelium. Direct assessment of the relative contribution of the different mechanisms of pleural fluid removal is difficult, due to the difficulty in measuring the relevant parameters in the appropriate areas, and to the fragility of the mesothelium. The role of the visceral pleura in pleural fluid removal under physiological conditions is supported by a number of findings and considerations. Further evidence indicates that direct lymphatic drainage through the stomas of the parietal pleura is crucial in removing particles and cells, and important in removing protein from the pleural space, but should not be the main effector of fluid removal. Its importance, however, increases markedly in the presence of increased intrapleural liquid loads. Removal of protein and liquid by transcytosis, although likely on the basis of morphological findings and suggested by recent indirect experimental evidence, still needs to be directly proven to occur in the pleura. When pleural liquid volume increases, an imbalance occurs in the forces involved in turnover, which favours fluid removal. In case of a primary abnormality of one ore more of the mechanisms of pleural liquid turnover, a pleural effusion ensues. The factors responsible for pleural effusion may be subdivided into three main categories: those changing transpleural pressure balance, those impairing lymphatic drainage, and those producing increases in mesothelial and capillary endothelial permeability. Except in the first case, pleural fluid protein concentration increases above normal: this feature underlies the classification of pleural effusions into transudative and exudative.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1183/09031936.02.00062102

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 38 references

Cited by

See all 209

Metadata

Authors
Zocchi, L.
Venue
European Respiratory Journal
Published
2002-12
Volume
20
Issue
6
Pages
1545-1558
ISSN
  • 0903-1936 (ISSN-L)
  • 1399-3003
OpenAlex
W2153716216
Cited by
209
References
38
FWCI
3.13
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Physiology and pathophysiology of pleural fluid turnover. https://app.cochat.ai/papers/10.1183/09031936.02.00062102
The paper
Zocchi, L. (2002). Physiology and pathophysiology of pleural fluid turnover. European Respiratory Journal. https://doi.org/10.1183/09031936.02.00062102

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.