Equipment needs for noninvasive mechanical ventilation
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Noninvasive mechanical ventilation (NIV) has a long tradition for the treatment of chronic respiratory failure and more recently has also been applied in acute respiratory failure. Based on this experience both critical care ventilators and portable ventilators are used to perform NIV. The individual choice of ventilator type should depend on the patient's condition and also on the expertise of attending staff, therapeutic requirements and the location of care. The majority of studies have used pressure-targeted ventilation in the assist mode. Positive qualities of pressure support ventilation (PSV) are leak compensation, good patient/ventilator synchrony and the option of integrated positive end-expiratory pressure to counteract the effect of dynamic hyperinflation. In this article, some crucial issues concerning PSV (i.e.triggering into inspiration, pressurisation, cycling into expiration and carbon dioxide rebreathing) and some corrective measures are discussed. The parameters which should be monitored during noninvasive ventilation are presented. The interface between patient and ventilator is a crucial issue of noninvasive ventilation. Advantages and disadvantages of face and nasal masks are discussed. Finally, causes and possible remedies of significant air leaks and some technical accessories for noninvasive ventilation are dealt with.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hilbert, G., Gruson, D., Vargas, F., Valentino, R., Gbikpi-Benissan, G., Dupon, M., Reiffers, J., & Cardinaud, J. P. (2001) · New England Journal of Medicine · doi:10.1056/nejm200102153440703 · Cited by 1,045 · cited 1×
“The delivery of a high Fi,O2 may be impossible using a portable ventilator and therefore CC ventilators, or those with an integral blender, are preferred when oxygenation is severely compromised, for instance in patients with acute lung injury [8, 51, 52].”
Antonelli, M., Conti, G., Rocco, M., Bufi, M., De Blasi, R. A., Vivino, G., Gasparetto, A., & Meduri, G. U. (1998) · New England Journal of Medicine · doi:10.1056/nejm199808133390703 · Cited by 1,014
Bott, J., Carroll, M. P., Conway, J. H., Keilty, S. E. J., Ward, E. M., Brown, A. M., Paul, E. A., Elliott, M. W., Godfrey, R. C., Wedzicha, J. A., et al. (1993) · The Lancet · doi:10.1016/0140-6736(93)90696-e · Cited by 849 · cited 1×
“Compared to PSV volume-targeted ventilators are rarely used in ARF and were only used exclusively in one study [29].”
&NA; (2001) · Survey of Anesthesiology · doi:10.1097/00132586-200110000-00014 · Cited by 797
(2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.1.ats1000 · Cited by 790
Appendini, L., Patessio, A., Zanaboni, S., Carone, M., Gukov, B., Donner, C. F., & Rossi, A. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.149.5.8173743 · Cited by 515 · cited 1×
“External PEEP, which is an integral option in pressure-targeted ventilators, is set to counteract the effect of intrinsic PEEP on ventilator triggering and work of breathing [22].”
Delclaux, C., L'Her, E., Alberti, C., Mancebo, J., Abroug, F., Conti, G., Guérin, C., Schortgen, F., Lefort, Y., Antonelli, M., et al. (2000) · JAMA · doi:10.1001/jama.284.18.2352 · Cited by 512 · cited 1×
“It has been used in ARF caused by a variety of aetiologies with variable success [5, 6].”
Petrof, B. J., Legaré, M., Goldberg, P., Milic-Emili, J., & Gottfried, S. B. (1990) · American Review of Respiratory Disease · doi:10.1164/ajrccm/141.2.281 · Cited by 486 · cited 9×
“The risk of rebreathing is greater with high respiratory rates and low external PEEP because these are associated with shorter expiratory times and low CO2 lavage from the circuit.”
InfluentialNoninvasive Versus Conventional Mechanical Ventilation: An Epidemiologic Survey
CARLUCCI, A., RICHARD, J.-C., WYSOCKI, M., LEPAGE, E., BROCHARD, L., & the SRLF Collaborative Group on Mechanical Ventilation (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.4.2006027 · Cited by 484 · cited 3×
“Unsurprisingly, in a French epidemiological survey concerning the use of NIV in intensive care units, there was a predominance of CC ventilators used (76% compared with 24% portable ventilators) in the treatment of ARF [8].”
Noninvasive Positive Pressure Ventilation Via Face Mask
Meduri, G. U., Turner, R. E., Abou-Shala, N., Wunderink, R., & Tolley, E. (1996) · Chest · doi:10.1378/chest.109.1.179 · Cited by 482 · cited 1×
“The improvement in arterial blood gas tensions appear to be slower in some studies using nasal masks compared to face masks [42].”
Metadata
- Authors
- Schönhofer, B., & Sortor-Leger, S.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2002-10
- Volume
- 20
- Issue
- 4
- Pages
- 1029-1036
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2103656506
- Cited by
- 169
- References
- 38
- FWCI
- 3.39
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Equipment needs for noninvasive mechanical ventilation. https://app.cochat.ai/papers/10.1183/09031936.02.00404202
- The paper
- Schönhofer, B., & Sortor-Leger, S. (2002). Equipment needs for noninvasive mechanical ventilation. European Respiratory Journal. https://doi.org/10.1183/09031936.02.00404202
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.