Equipment needs for noninvasive mechanical ventilation
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Noninvasive mechanical ventilation (NIV) has a long tradition for the treatment of chronic respiratory failure and more recently has also been applied in acute respiratory failure. Based on this experience both critical care ventilators and portable ventilators are used to perform NIV. The individual choice of ventilator type should depend on the patient's condition and also on the expertise of attending staff, therapeutic requirements and the location of care. The majority of studies have used pressure-targeted ventilation in the assist mode. Positive qualities of pressure support ventilation (PSV) are leak compensation, good patient/ventilator synchrony and the option of integrated positive end-expiratory pressure to counteract the effect of dynamic hyperinflation. In this article, some crucial issues concerning PSV (i.e.triggering into inspiration, pressurisation, cycling into expiration and carbon dioxide rebreathing) and some corrective measures are discussed. The parameters which should be monitored during noninvasive ventilation are presented. The interface between patient and ventilator is a crucial issue of noninvasive ventilation. Advantages and disadvantages of face and nasal masks are discussed. Finally, causes and possible remedies of significant air leaks and some technical accessories for noninvasive ventilation are dealt with.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hilbert, G., Gruson, D., Vargas, F., Valentino, R., Gbikpi-Benissan, G., Dupon, M., Reiffers, J., & Cardinaud, J. P. (2001) · New England Journal of Medicine · doi:10.1056/nejm200102153440703 · Cited by 1,045 · cited 1×
“The delivery of a high Fi,O2 may be impossible using a portable ventilator and therefore CC ventilators, or those with an integral blender, are preferred when oxygenation is severely compromised, for instance in patients with acute lung injury [8, 51, 52].”
Antonelli, M., Conti, G., Rocco, M., Bufi, M., De Blasi, R. A., Vivino, G., Gasparetto, A., & Meduri, G. U. (1998) · New England Journal of Medicine · doi:10.1056/nejm199808133390703 · Cited by 1,014
Bott, J., Carroll, M. P., Conway, J. H., Keilty, S. E. J., Ward, E. M., Brown, A. M., Paul, E. A., Elliott, M. W., Godfrey, R. C., Wedzicha, J. A., et al. (1993) · The Lancet · doi:10.1016/0140-6736(93)90696-e · Cited by 849 · cited 1×
“Compared to PSV volume-targeted ventilators are rarely used in ARF and were only used exclusively in one study [29].”
&NA; (2001) · Survey of Anesthesiology · doi:10.1097/00132586-200110000-00014 · Cited by 797
(2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.1.ats1000 · Cited by 790
Appendini, L., Patessio, A., Zanaboni, S., Carone, M., Gukov, B., Donner, C. F., & Rossi, A. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.149.5.8173743 · Cited by 515 · cited 1×
“External PEEP, which is an integral option in pressure-targeted ventilators, is set to counteract the effect of intrinsic PEEP on ventilator triggering and work of breathing [22].”
Delclaux, C., L'Her, E., Alberti, C., Mancebo, J., Abroug, F., Conti, G., Guérin, C., Schortgen, F., Lefort, Y., Antonelli, M., et al. (2000) · JAMA · doi:10.1001/jama.284.18.2352 · Cited by 512 · cited 1×
“It has been used in ARF caused by a variety of aetiologies with variable success [5, 6].”
Petrof, B. J., Legaré, M., Goldberg, P., Milic-Emili, J., & Gottfried, S. B. (1990) · American Review of Respiratory Disease · doi:10.1164/ajrccm/141.2.281 · Cited by 486 · cited 9×
“The risk of rebreathing is greater with high respiratory rates and low external PEEP because these are associated with shorter expiratory times and low CO2 lavage from the circuit.”
InfluentialNoninvasive Versus Conventional Mechanical Ventilation: An Epidemiologic Survey
CARLUCCI, A., RICHARD, J.-C., WYSOCKI, M., LEPAGE, E., BROCHARD, L., & the SRLF Collaborative Group on Mechanical Ventilation (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.4.2006027 · Cited by 484 · cited 3×
“Unsurprisingly, in a French epidemiological survey concerning the use of NIV in intensive care units, there was a predominance of CC ventilators used (76% compared with 24% portable ventilators) in the treatment of ARF [8].”
Noninvasive Positive Pressure Ventilation Via Face Mask
Meduri, G. U., Turner, R. E., Abou-Shala, N., Wunderink, R., & Tolley, E. (1996) · Chest · doi:10.1378/chest.109.1.179 · Cited by 482 · cited 1×
“The improvement in arterial blood gas tensions appear to be slower in some studies using nasal masks compared to face masks [42].”
Patrick, W. D., Webster, K., Ludwig, L., ROBERTS, D. E., Wiebe, P., & Younes, M. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.153.3.8630538 · Cited by 422 · cited 1×
“Currently, however, PAV remains an experimental ventilation mode and its clinical impact as a mode for NIV has not been established [28].”
Reappraisal of Continuous Positive Airway Pressure Therapy in Acute Cardiogenic Pulmonary Edema
Lin, M., Yang, Y.-F., Chiang, H.-T., Chang, M.-S., Chiang, B. N., & Cheitlin, M. D. (1995) · Chest · doi:10.1378/chest.107.5.1379 · Cited by 322
Navalesi, P., Fanfulla, F., Frigerio, P., Gregoretti, C., & Nava, S. (2000) · Critical Care Medicine · doi:10.1097/00003246-200006000-00015 · Cited by 316 · cited 3×
“In a prospective randomised study comparing both modes in hypercapnic respiratory failure no difference was shown in terms of patient tolerance and quality of ventilation [31].”
Massie, C. A., Hart, R. W., Peralez, K., & Richards, G. N. (1999) · Chest · doi:10.1378/chest.116.2.403 · Cited by 308 · cited 1×
“hours of usage) with CPAP was found in patients with heated humidification compared to unheated humidifiers and no humidification at all [50].”
Mouth leak with nasal continuous positive airway pressure increases nasal airway resistance.
Richards, G. N., Cistulli, P. A., Ungar, R. G., Berthon-Jones, M., & Sullivan, C. E. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.154.1.8680678 · Cited by 281 · cited 3×
“It has been shown that despite a severe mouth leak, heated humidification significantly increased relative humidity in the airways [49] and reduced nasal resistance [47].”
Pang, D., Keenan, S. P., Cook, D. J., & Sibbald, W. J. (1998) · Chest · doi:10.1378/chest.114.4.1185 · Cited by 277 · cited 1×
“It has been used in ARF caused by a variety of aetiologies with variable success [5, 6].”
Togias, A. G., Naclerio, R. M., Proud, D., Fish, J. E., Adkinson, N. F., Kagey-Sobotka, A., Norman, P. S., & Lichtenstein, L. M. (1985) · Journal of Clinical Investigation · doi:10.1172/jci112113 · Cited by 261 · cited 1×
“This is also known to promote the release of inflammatory mediators and to increase nasal airway resistance [47, 48], which increases mouth breathing and further leakage.”
Proportional Assist Ventilation: Results of an Initial Clinical Trial
Younes, M., Puddy, A., Roberts, D., Light, R. B., Quesada, A., Taylor, K., Oppenheimer, L., & Cramp, H. (1992) · American Review of Respiratory Disease · doi:10.1164/ajrccm/145.1.121 · Cited by 257 · cited 1×
“Proportional assist ventilation (PAV) has recently been proposed as a mode of synchronised partial ventilatory support in which the ventilator pressure output is proportional to instantaneous patient effort [23].”
Patient-ventilator asynchrony during noninvasive ventilation: the role of expiratory trigger
Calderini, E., Confalonieri, M., Puccio, P. G., Francavilla, N., Stella, L., & Gregoretti, C. (1999) · Intensive Care Medicine · doi:10.1007/s001340050927 · Cited by 245 · cited 1×
“These are important features, especially during the first period of ventilation when it is important to assess the patient/ventilator interaction, respiratory mechanics, and the expired tidal volume [40].”
Vitacca, M., Rubini, F., Foglio, K., Scalvini, S., Nava, S., & Ambrosino, N. (1993) · Intensive Care Medicine · doi:10.1007/bf01711086 · Cited by 213
Effect of mouth leak on effectiveness of nasal bilevel ventilatory assistance and sleep architecture
Teschler, H., Stampa, J., Ragette, R., Konietzko, N., & Berthon-Jones, M. (1999) · European Respiratory Journal · doi:10.1183/09031936.99.14612519 · Cited by 196 · cited 11×
“The topic "Equipment for noninvasive ventilation", with respect to both CRF and ARF, is characterised by the discrepancy between increasing usage and a severe dearth of evidence that supports specific strategies.”
InfluentialCO2 rebreathing during BiPAP ventilatory assistance.
Ferguson, G. T., & Gilmartin, M. (1995) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.151.4.7697242 · Cited by 188 · cited 1×
“Carbon dioxide (CO2) rebreathing has been documented with some common home bilevel ventilators that have a single gas delivery circuit and do not contain a true exhalation valve [18, 19].”
Proportional Assist Ventilation
Younes, M. (2003) · Mechanical Ventilation and Weaning · doi:10.1007/978-3-642-56112-2_3 · Cited by 169
de Araújo, M. T. M., Vieira, S. B., Vasquez, E. C., & Fleury, B. (2000) · CHEST Journal · doi:10.1378/chest.117.1.142 · Cited by 168 · cited 1×
“It has been shown that despite a severe mouth leak, heated humidification significantly increased relative humidity in the airways [49] and reduced nasal resistance [47].”
Girault, C., Richard, J.-C., Chevron, V., Tamion, F., Leroy, J., Bonmarchand, G., & Pasquis, P. (1997) · CHEST Journal · doi:10.1378/chest.111.6.1639 · Cited by 166 · cited 1×
“[34] found similar improvements in breathing pattern and gas exchange.”
Leak compensation in positive pressure ventilators: a lung model study
Mehta, S., McCool, F. D., & Hill, N. S. (2001) · European Respiratory Journal · doi:10.1183/09031936.01.17202590 · Cited by 145 · cited 2×
“Based on another test lung model it has been found that leak compensating capabilities between six different devices differed markedly [7].”
Efficacy of a New Full Face Mask for Noninvasive Positive Pressure Ventilation
Criner, G. J., Travaline, J. M., Brennan, K. J., & Kreimer, D. T. (1994) · CHEST Journal · doi:10.1378/chest.106.4.1109 · Cited by 131 · cited 1×
“Compared to nasal masks, face masks are generally more claustrophobic, impede communication, limit oral intake and increase the dead space [44] which may cause CO2 rebreathing.”
Antonelli, M. M., Conti, G., Rocco, M., et al. (1999) · Survey of Anesthesiology · doi:10.1097/00132586-199908000-00016 · Cited by 124 · cited 1×
“The delivery of a high Fi,O2 may be impossible using a portable ventilator and therefore CC ventilators, or those with an integral blender, are preferred when oxygenation is severely compromised, for instance in patients with acute lung injury [8, 51, 52].”
Schönhofer, B., Sonneborn, M., Haidl, P., Bohrer, H., & Köhler, D. (1997) · European Respiratory Journal · doi:10.1183/09031936.97.10010184 · Cited by 123 · cited 1×
“[38] compared volume-targeted ventilation and pressure-targeted ventilation consecutively, both in the controlled mode over 4 weeks in a sequential manner.”
Self-citationWysocki, M., Richard, J.-C., & Meshaka, P. (2002) · Critical Care Medicine · doi:10.1097/00003246-200202000-00010 · Cited by 102
Restrick, L., Fox, N. C., Braid, G. M., Ward, E., Paul, E. A., & Wedzicha, J. A. (1993) · European Respiratory Journal · doi:10.1183/09031936.93.06030364 · Cited by 78
Noninvasive Ventilator Triggering in Chronic Obstructive Pulmonary Disease
Stell, I. M., Paul, G. R., Lee, K., Ponte, J., & Moxham, J. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.11.2011147 · Cited by 72 · cited 1×
“In a test lung model, designed to simulate an acute exacerbation of COPD, the triggering behaviour of 13 different ventilators was studied [13].”
P3-Specific Amplitude Reductions to Respiratory and Auditory Stimuli in Subjects with Asthma
Webster, K. E., & Colrain, I. M. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2012006 · Cited by 50
Elliott, M. W., Mulvey, D. A., Moxham, J., GREEN, M., & Branthwaite, M. A. (1993) · Anaesthesia · doi:10.1111/j.1365-2044.1993.tb06782.x · Cited by 31 · cited 1×
“COPD is characterised by dynamic hyperinflation and intrinsic PEEP, which may cause patient/ventilator asynchrony [20, 21] and an increase in the work of breathing.”
Oscillations and Noise: Inherent Instability of Pressure Support Ventilation?
Hotchkiss, J. R., ADAMS, A. B., Stone, M. K., Dries, D. J., Marini, J. J., & Crooke, P. S. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.165.1.2101025 · Cited by 31 · cited 1×
“[14] showed that unstable behaviour of the ventilator performance could impose breath-to-breath variability in the effort required for inspiratory triggering.”
Smith, I. E., & Shneerson, J. M. (1997) · Thorax · doi:10.1136/thx.52.1.89 · Cited by 24 · cited 2×
“SMITH and SHNEERSON [37] reported an improvement in diurnal blood gas tensions in patients who switched from volume-targeted ventilation to pressure-targeted ventilation.”
NIPPV: patient–ventilator synchrony, the difference between success and failure?
Kacmarek, R. M. (1999) · Intensive Care Medicine · doi:10.1007/s001340050924 · Cited by 22 · cited 1×
“The evaluation of patient/ventilator asynchrony is more difficult without visualisation of flow and pressure waveforms [39].”
What is really important to make noninvasive ventilation work
Brochard, L. J. (2000) · Critical Care Medicine · doi:10.1097/00003246-200006000-00084 · Cited by 21 · cited 1×
“Compared to nasal masks, the more common application of full face masks in ARF is also a reflection of better quality of ventilation (at least during the initial phase of the intervention) in terms of minute ventilation and improved blood gases [31, 43].”
Metadata
- Authors
- Schönhofer, B., & Sortor-Leger, S.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2002-10
- Volume
- 20
- Issue
- 4
- Pages
- 1029-1036
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2103656506
- Cited by
- 169
- References
- 38
- FWCI
- 3.39
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.